• Title/Summary/Keyword: Internal voltage

Search Result 659, Processing Time 0.024 seconds

Dielectric Breakdown Voltage and Dielectric Properties of High Voltage Mutilayer Ceramic Capacitor with C0G Temperature Coefficient Characteristics (C0G 온도계수 특성을 가지는 고압용 적층 칩 캐패시티의 유전 및 내전압 특성)

  • Yoon, Jung-Rag;Woo, Byong-Chul;Chung, Tae-Serk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.2
    • /
    • pp.137-143
    • /
    • 2008
  • High voltage MLCCs with C0G temperature coefficient characteristics could apply DC-DC invertor were investigated for its dielectric properties. Also we manufactured MLCC through various process and studied the characteristics of dielectric break down voltage [BDV] and dielectric property as the variation of thickness in the green sheet and how to pattern the internal electrode. As the thickness of green sheet is increase, the dielectric BDV per unit thickness is decreased. But as the pattern of internal electrodes were floated we could manufacture the high voltage MLCC maintained its dielectric BDV a unit.

Transition of voltage-differential current under internal fault on power transformer (전력용 변압기 내부고장시 전압-차전류의 변화에 관한 연구)

  • Park, Jae-Sae
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.92-95
    • /
    • 2004
  • Power transformer is an important apparatus in transforming and delivering the power in a power system. It shows less accident ratio than other system apparatus, but once the accident occurs, it causes long-term operation stoppage and economic loss. It brings high bad spillover effects. Therefore, the role of protective relaying, which is to prevent internal fault a power transformer is highly important. This study proposed advanced algorithm that can clearly determine internal fault of the power transformer and magnetizing inrush, through numerical analysis by using the terminal voltage and input output current.

  • PDF

혈액정화장치의 현황과 문제점

  • 박한철
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.102-105
    • /
    • 1989
  • In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research.

  • PDF

A Study on the Optimal Design of LLC Resonant Half-bridge dc-dc Converter Using a Steady-state Model with Internal Loss Resistors (내부 손실 저항이 있는 정상상태 모델을 이용한 LLC 공진형 하프 브리지 dc-dc컨버터의 최적 설계에 관한 연구)

  • Yoo, Jeong Sang;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.80-86
    • /
    • 2022
  • In this paper, the optimal design and circuit simulation verification results of an LLC resonant half-bridge dc-dc converter using a steady-state model with internal loss resistance are reported. Above all, the input/output voltage gain and frequency characteristic equations in the steady-state were derived by reflecting the internal loss resistance in the equivalent circuit. Based on the results, an LLC resonant half-bridge dc-dc converter with an input voltage of 360-420V, an output voltage of 54V, and a maximum power of 3kW was designed, and to verify the design, the PSIM circuit simulation was executed to compare and analyze the result. In particular, the operating range of the converter could be drawn from the frequency characteristic graph of the voltage gain, and when the converter was operated under light and maximum load conditions, it was confirmed that similar results were obtained by comparing simulation results and calculation results in the switching frequency characteristic graph. In addition, the change of the switching frequency with respect to the load current at each input voltage was compared with the calculated value and the simulation result. As a result, it was possible to confirm the usefulness of the analysis result reflecting the internal loss resistance proposed in this paper and the process of the optimal design.

A Method for Reducing the Residual Voltage of Hybrid SPD Circuit Using Choke Coils (초크코일을 이용한 SPD 조합회로의 잔류전압 저감기법)

  • Cho, Sung-Chul;Eom, Ju-Hong;Lee, Tae-Hyung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.250-253
    • /
    • 2007
  • Gas Discharge Tubes (GDTs) are widely used as surge protectors for commnuication applications due to their small internal capacitance. In these days, however, they are mostly used in combined configurations, because the activation voltage required to initiate the discharge process in the GDTs for sufficient amount of time can be large enough to damage surge-sensitive protected circuits. For GDTs with a considerably high initial over-voltage value, we should limit the peak voltage using a TVS or filter. As for ZnO varistors, even though their performance for voltage restriction is excellent, their applications in high-frequency commnuication circuits have been limited because of higher internal capacitance when compared to the GDTs. In order to develop a surge protector for commnuication applications by taking advantages of these two devices, we built a combination circuit that connects a GDT and a ZnO varistor along with a choke coil in common and differential modes. We describe how the applied SPDs operate in protection process steps with the actual data obtained from the residual voltage measurements at each step. The experiment results show that the surge voltage restriction with the choke coil is more effective in 100 [kHz] RingWave voltage than in lightning impulse voltage.

  • PDF

Arc Phenomena and Induced Voltage due to Inductive Energy of Superconducting Coil (초전도 코일의 유도성 에너지에 의한 아크현상과 유기 과전압)

  • 최병주;류경우;성기철;김해종
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.24-30
    • /
    • 2000
  • This paper present the characteristics of the internal induced voltage and arc phenomena in liquid helium at the energy transfer from a superconducting magnet to a load resistor. Especially generation mechanism of the oscillated wave from of the coil terminal voltage is analyzed by considering circuit constant of the superconducting magnet, load condition and arc resistance of the mechanical opening switch. The wavefront and peak portion of the voltage are strongly influenced by arc discharge triggered by the switch separation in liquid helium. Abrupt arc extinction leads to voltage oscillation with an enormous peak. It is suggested that the superconducting magnet should be designed to ensure the internal surge when arc is possibly formed by switch opening or coil short circuit between turns or layers. Finally, a suppression method of the oscillating surge is proposed based on the load condition.

  • PDF

Analysis of Resonant Characteristics in High Voltage Windings of Main Transformer for Railway Vehicle using EMTP (EMTP를 이용한 철도차량용 주변압기 고압권선의 공진특성 분석)

  • Jeong, Ki-Seok;Jang, Dong-Uk;Chung, Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.436-444
    • /
    • 2016
  • The primary windings of the main transformer for rolling stock have several natural frequencies that can occur internal resonance with transient voltages induced on a high voltage feeding line. Factory testing is limited in its ability to determine whether or not transient voltage with various shape and duration can be excitable. This study presents the design of a high voltage windings model and simulation and analysis of the internal resonant characteristics in terms of the initial voltage distribution and voltage-frequency relationship using the electromagnetic transients program (EMTP). Turn-based lumped-parameters are calculated using the geometry data of the transformer. And, sub-models, being grouped into the total number of layers, are composed using a ladder-network model and implemented by the library function of EMTP. Case studies are used to show the layer-based voltage-frequency relationship characteristics according to the frequency sweep and the voltage escalation and distribution aspects in time-domain simulation.

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF

Charge Accunmulation Characteristics in LDPE (저밀도 폴리에틸렌의 전하축적 특성)

  • ;;Tatsuo Takada
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.1
    • /
    • pp.42-49
    • /
    • 1992
  • Charge accumulation characteristics in low density polyethylene (LDPE) has been discussed based upon the internal charge distrubution measured by the pulsed electroacoustic technique. When the negative voltage with respect to earth is applied to the upper electrode, the negative charges near the anode and the positive charges near the cathode are accumulated in LDPE. Also, there was an asymmetric behavior of charge accumulation exhibiting that the charge accumulation near the anode keeps increasing whereas that near the cathode increases first and then decreases. Besides, under the present test conditions the internal charge distrubution becomes stabilized eventually. When the positive voltage with respect to earth is applied to the upper electrode, on the other hand, no such asymmetric charge accumulation was found. Therefore, it can be concluded that the heterocharges are accumulated at the surface region of LDPE subjected to high do voltages and that the begavior of charge accumulation depends on the polarity of do voltage and the position of charge accumulation.

  • PDF

Study on Testing Enclosed low-voltage switchgear and controlgear assemblies Under conditions of arcing due to internal faults (내부고장으로 인한 아크상태의 저압배전반 시험방법 동향 고찰)

  • Kim, Sun-Ho;Kim, Sun-Koo;Roh, Chang-Il;Jung, Heung-Soo;Kim, Won-Man;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.927-928
    • /
    • 2007
  • Recently IEC has made considerations on testing Enclosed low-voltage switchgear and controlgear assemblies under conditions of arcing due to internal faults. This paper will make a study on testing Enclosed low-voltage switchgear and controlgear assemblies under conditions of arcing due to internal faults that is suggested by IEC.

  • PDF