• Title/Summary/Keyword: Internal oblique

Search Result 326, Processing Time 0.022 seconds

The Effects of Smooth Pursuit Eye Movement and Saccadic Eye Movement on Balance and Muscle Activation during One Leg Standing (한 다리 서기 동안 매끈눈따라보기와 신속눈운동이 균형과 근활성도에 미치는 영향)

  • Young-Bum, Jung;Gyu-Ryeong, Kim;Myoung-Kwon, Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.4
    • /
    • pp.113-121
    • /
    • 2022
  • PURPOSE: This study is examined the effects of vestibular stimulation through eye movement on balance and muscle activity. METHODS: In 42 healthy adults, no eye exercise was applied to both feet and one foot. The speed of smooth pursuit eye movement (.2 Hz, .3 Hz, and .5 Hz) and saccadic eye movement (.5 Hz and 1.1 Hz) were randomized. The measurements were taken three times for 30 seconds while standing on two feet and measured three times for 10 seconds while standing on one foot. The muscle activity measurement equipment was used to measure the electromyogram signals of the tibialis anterior, peroneus longus, gastrocnemius medialis, vastus medialis, vastus lateralis, biceps femoris, abdominal internal oblique, and erector spinae muscle. RESULTS: As a result of this study, when applying smooth pursuit eye movement on one leg, the pressure center movement increased, the muscle activity of the lower extremity increased, in the saccadic eye movement, and the center of pressure decreased. CONCLUSION: Accordingly, the smooth pursuit of eye movement, the intervention of this study, affects balance. Through this, the balance can be improved by applying eye movement to the target who needs to improve the balance ability.

The Effect of Seating Surface Angle on the Deep Abdominal Muscle and Lower Limb Muscle Thickness in Normal Adults (앉는 면의 각도가 정상성인의 심부 복근과 다리근육 두께에 미치는 영향)

  • Ha, Seong-Yeong;Kim, Kyoung;Im, Sang-Cheol
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.3
    • /
    • pp.131-140
    • /
    • 2022
  • Purpose : Although many studies have explored the effect of seating side angles on the spinal curve and surrounding muscles during seating, only a few studies have investigated the effect of different seating face angles on different lower limb and deep trunk muscles. Therefore, this study investigated the effects of seating surface angles (0 degrees, 10 degree anterior, and 10 degree rear) on lower extremity and deep trunk muscles in healthy adults. Methods : Thirty people were asked to sit once on each seating surface three times during the day, and their muscle thicknesses were measured by ultrasound while sitting. The method of sitting was the same when sitting on the three seating surfaces. Results : From the comparison results of the muscle thicknesses according to the seating surface angles, a significant difference existed in the muscle thicknesses of the vastus medialis, vastus medialis oblique, vastus intermedius, soleus and gastrocnemius (p<.05). However, no significant difference was found in the transversus abdominis, internal obliques, rectus femoris and vastus lateralis (p>.05). Conclusion : Our findings revealed that the lower back load decreases, the leg load increases, and the legs specific muscles are affected as the body tilts forward when sitting on the seating surface inclined forward. Therefore, it is possible to suggest a forwardly inclined seating surface that reduces lower back loads and utilizes the posture-maintaining muscles of the legs when sitting in a person with a poor sitting posture or lower back pain at ordinary times.

Effects of Core Exercise on Body Composition, Abdominal Muscle Thickness, Trunk Muscular Endurance, and Psychological Factors in Normal-weight Obese Women (코어운동이 마른 비만 여성의 신체조성과 복부 근육두께, 몸통 근지구력, 심리적 요인에 미치는 영향)

  • Sang Ho Kim;Tae Hwa Seo;Nam Gi Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.3
    • /
    • pp.72-83
    • /
    • 2023
  • Background: Normal-weight obese women have a normal weight with relatively low muscle mass resulting from high body fat. We aimed to investigate the effects of core exercise on body composition, abdominal muscle thickness, trunk muscular endurance, and psychological factors in normal-weight obese women. Design: One group pre-, mid-, and post-test design. Methods: A total of 20 normal-weight obese women were recruited voluntarily. Core exercises were performed for 30 minutes, three times a week for 4 weeks. InBody measurements, ultrasound imaging, and clinical tests were used to assess body composition, abdominal muscle thickness, trunk and core muscular endurance, and psychological condition(satisfaction with appearance and self-esteem). The dependent variables were measured three times: before the intervention (pre-test), 2 weeks after the intervention (mid-test), and 4 weeks after intervention (post-test). One-way repeated measures ANOVA and Friedman test were used for statistical analysis. Results: Although there was no change in the body composition (p>0.05), thickness of the transversus abdominis and internal and external oblique muscles, endurance of the trunk flexors and extensors and core muscles, and psychological condition showed significant differences after the intervention (p<0.05). Conclusion: Our findings will help develop exercise programs for normal-weight obese individuals that utilize the beneficial effect of core exercises.

X-ray Arcelin Projection Study for Diagnosing Mastoid Process and Petrous Ports (꼭지돌기와 바위부 진단을 위한 엑스선 Arcelin 촬영법 연구)

  • Jun-Haeng Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.301-307
    • /
    • 2024
  • The Study Evaluated Radiography Images using the Mastoid Process Axial Oblique Projection (Arcelin) imaging method for the Diagnosis of Pyramid Ridge, Mastoid Process, Mastoid Process air cells, Tympanum, Internal auditory and petrous in Supine Position. The subjective ROC (receiver operation characteristic) evaluation method was conducted on five Radiological technologists who have worked in the Image medical Department of University Hospitals for more than 8 years, and the Objective Evaluation, signal-to-noise Ratio (SNR), was evaluated and Analyzed. The Cronbach Alpha value was significantly higher at 0.816. In the Image ROC Evaluation Taken by Tilting the X-ray Tube 5°, 10°, 15° toward the leg by 10°, it Scored 34 points, and in the overall evaluation, the SNR scored high at 6,549. In Addition, In the Image Evaluation taken by Tilting the X-ray Tube 5°, 10°, and 15° toward the head, it Scored 32 points In the Image ROC Evaluation taken by tilting 5°, and in the Objective Evaluation, SNR received the highest score of 6,732.

The prospective preliminary clinical study of open reduction and internal fixation of mandibular angle fractures using 2 miniplates (하악 우각부 골절 시 2개의 miniplate를 이용한 관혈적 정복술에 대한 전향적 예비 임상연구)

  • Yang, Seung-Bin;Jang, Chang-Su;Kim, Ju-Won;Yim, Jin-Hyuk;Kim, Jwa-Young;Yang, Byoung-Eun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.320-324
    • /
    • 2010
  • Introduction: The placement of a single miniplate is not sufficient to achieve rigid fixation in mandibular angle fractures. It often causes difficulties in reducing the intermaxillary fixation (IMF) period. Consequently, the placement of 2 miniplates is preferable. The intraoral approach in an open reduction and internal fixation (ORIF) of a mandibular angle fracture with 2 miniplates is often challenging. Accordingly, an alternative of transbuccal approach is performed. However, this method leaves a scar on the face and can result in facial nerve injury. This clinical study suggests a protocol that can maintain rigid fixation without a transbuccal approach in mandibular angle fractures. Materials and Methods: The subjects were 7 patients who sustained fractures of the mandibular angle and treated at Department of Oral and maxillofacial surgery, Sacred Heart Hospital, Hallym University. ORIF under general anesthesia was done using the intraoral approach. One miniplate was inserted on external oblique ridge of the mandible, and the other was placed on lateral surface of the mandibular body with contra-angle drill and driver. A radiographic assessment and occlusal contact point examination was carried out before surgery, and 2, 4 and 6 weeks after surgery. Results: The mean operation time was 80 minutes. Regarding the occlusion state, the number of contact points increased after surgery. Paresthesia and infection were reported to be complications before surgery. Conclusion: The placement of 2 miniplates using contra-angle drill for ORIF of mandibular angle fractures allows early movement of the mandible without IMF. We propose this approach to reduce the patients’discomfort and simplify the surgical procedure.

Regional Distribution of Interstitial Cells of Cajal, (ICC) in Human Stomach

  • Yun, Hyo-Yung;Sung, Ro-Hyun;Kim, Young-Chul;Choi, Woong;Kim, Hun-Sik;Kim, Heon;Lee, Gwang-Ju;You, Ra-Young;Park, Seon-Mee;Yun, Sei-Jin;Kim, Mi-Jung;Kim, Won-Seop;Song, Young-Jin;Xu, Wen-Xie;Lee, Sang-Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.14 no.5
    • /
    • pp.317-324
    • /
    • 2010
  • We elucidated the distribution of interstitial cells of Cajal (ICC) in human stomach, using cryosection and $c-Kit$ immunohistochemistry to identify $c-Kit$ positive ICC. Before $c-Kit$ staining, we routinely used hematoxylin and eosin (HE) staining to identify every structure of human stomach, from mucosa to longitudinal muscle. HE staining revealed that the fundus greater curvature (GC) had prominent oblique muscle layer, and $c-Kit$ immunostaining $c-Kit$ positive ICC cells were found to have typical morphology of dense fusiform cell body with multiple processes protruding from the central cell body. In particular, we could observe dense processes and ramifications of ICC in myenteric area and longitudinal muscle layer of corpus GC. Interestingly, $c-Kit$ positive ICC-like cells which had morphology very similar to ICC were found in gastric mucosa. We could not find any significant difference in the distribution of ICC between fundus and corpus, except for submucosa where the density of ICC was much higher in gastric fundus than corpus. Furthermore, there was no significant difference in the density of ICC between each area of fundus and corpus, except for muscularis mucosa. Finally, we also found similar distribution of ICC in normal and cancerous tissue obtained from a patient who underwent pancreotomy and gastrectomy. In conclusion, ICC was found ubiquitously in human stomach and the density of ICC was significantly lower in the muscularis mucosa of both fundus/corpus and higher in the submucosa of gastric fundus than corpus.

Broden photographing method for Calcaneus Subtentaculum tali observation of Ankle plaster patient (발목부상을 당한 석고환자의 발꿈치뼈·목말받침돌기 관찰을 위한 Broden 촬영법 연구)

  • An, Byeongju
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • There is an Ankle Oblique(Broden' low) as an examination for the patient whose ankle was encased in orthopedic plaster. Some types of Ankle Joint coalition - Calcaneonavicular coalition, Talocalcaneal coalition and Naviculocuneiform coalition. This study is focused on the relation between Ankle Joints and the structural change of soft tissues, also finding the most proper angle to obtain good images of Ankle Joint from the patient who wore a plaster on his ankle, when we x-ray with Harris-Beath View($30^{\circ}{\sim}55^{\circ}$) - for observing Subtalar joint, Calcaneus Fracture, Subtentaculum, Tali Fracture and Talocalcaneal coalition. We intend to get the angle which makes us achieve the good image that shows Calcaneus Fracture, Subtentaculum, and Tali Fracture by changing internal angles of the patient's ankle. We evaluated the images obtained from 51 patients with PACS monitor. The result of the evaluation, subtalar joint was not seperated but opened, and Subtentaculum Tali Fracture was seen overlaid. at the angle 30, we could observe Calcaneus Fracture, Subtentaculum Tali Frature and the front part of behind side of subtalar joint well. And Calcaneo Navicularcoalition, Talocal Canealcoalition, Naviculo Cuneiform coalition condition were clearly seen at that angle. At the angle 35, we could achieve the clear images of subtalar comminuted fracture, talus, the behind joint of heel bone and get the high definition image on the degree of talocalcaneal joint separation. In addition to, We could obtain the good wide image of Sinus Tarsi. At the area of 45, We can distinguish the soft tissues from gyps separation. The outer-talus and density of the bone were definitely seen and Calcaneus is more separated than that of at the angle of 35, but this image is distorted. Calcaneus, Subtentaculum Tali show $1.20{\pm}0.414$ at the angle 25, $2.47{\pm}0.516$ at the angle 30, $2.27{\pm}0.458$ at the angle 45. This difference is statistically meaningful. (p<0.05). Including the degree of distortion, The distortion appears less at the area of $30^{\circ}$ but at the area of 40, there is heavy distortion. So, We could get the best image for making a diagnosis. At the $30{\sim}35^{\circ}$ degree for X-raying ankle. and at the $30{\sim}40^{\circ}$ for Calcaneus Fracture, Subtentaculum Tali Fracture.

Validity and Reliability of the Korean Version of the Global Assessment of Recent Stress Scale (전반적인 스트레스평가 척도 한국판의 타당도 및 신뢰도)

  • Koh, Kyung-Bong;Park, Joong-Kyu
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.8 no.2
    • /
    • pp.201-211
    • /
    • 2000
  • Objectives : The purpose of this study was to determine the validity and reliablity of the Korean version of the Global Assessment of Recent Stress(GARS) Scale developed for assessing the severity of current perceived stressors, and then to use the scale in clinical practice. Methods : The questionnaire was completed by 215 healthy subjects. A comparison was made regarding the perception of stressors among 242 patients(71 with anxiety disorder, 73 with depressive disorder, 47 with somatoform disorder, and 51 with psychosomatic disorder) and 215 healthy subjects. Factor analysis was done using oblique rotation after maximum-likelihood factor analysis. Results : Factor analysis yielded 1 subscale. Reliability was computed by administering the GARS Scale to 69 healthy subjects during a 2-week interval. Test-retest reliability for 8 items and the total score was significantly high, ranging between 0.85-.95. Internal consistency was significant(Cronbach's a for 7 items : .86). Convergent validity was computed by correlating the 8 items and the total score with the total score of the stress response inventory(SRI), the perceived stress questionnaire(PSQ), and the somatization, anxiety, depression, hostility subscales and general indices of the symptom checklist-90-revised(SCL-90-R). The correlations were all at significant levels. Discriminant validity was computed by comparing the 8 item scores of the patient and control groups. Significant differences were found in area relevant to sickness or illness and the overill global area. The patients with anxiety disorder were significantly higher in area relevant to sickness or illness than the healthy group, whereas the patients with depressive disorder was significantly higher in the overall global score than healthy group. The depressive disorder group was the highest in overall global score of the GARS scale among 4 patient groups, and showed a significant higher scores in interpersonal relationship and overall global area than the psychosomatic disorder group. Conclusions : These results indicate that the Korean version of the GARS scale is highly reliable and valid, and that it can be utilized as an effective measure of perceived stressors for research in stress-related fields. It is suggested that depressive disorder patients are more likely to perceive recent stressors than psychosomatic disorder patients.

  • PDF

Cold Test and Internal Flow Analysis of Semi-Freejet Type High Altitude Environment Simulation Test Facility for the High-Speed Vehicle (초고속 비행체를 위한 준 자유흐름식 고공환경 모사시험설비의 상온시험 및 내부유동 해석)

  • Lee, Seongmin;Yu, Isang;Choi, Jiseon;Oh, Junghwa;Shin, Minkyu;Ko, Youngsung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.290-296
    • /
    • 2018
  • In this study, the cold test and the numerical analysis were carried out according to the shape parameters of the test model in order to confirm the operation range of high altitude environment simulation test facility for the supersonic vehicle. The blockage ratio, angle and length ratio were considered as the design parameters. The blockage rate is expected to be limited in the region of more than 40% due to the normal shock and expansion fan. It was confirmed that the angle of model should be selected at the size of 45 degrees or less due to the influence of the strong shock wave. There was no difference in performance between the lengths of 8 times the model diameter. Finally, we obtained the performance database according to the shape parameters of the conical test model and confirmed the operable range of the semi-freejet type high altitude environment simulation test facility.

Wave Control by Bottom-Mounted and Fluid-Filled Flexible Membrane Structure (유체가 채워진 착저신 유연막 구조물에 의한 파랑제어)

  • 조일형;강창익
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.12 no.3
    • /
    • pp.139-148
    • /
    • 2000
  • In this paper, the interaction of oblique incident waves with a bottom-mounted and fluid-filled flexible membrane structure is investigated in the frame of linear hydro-elastic theory. The static shape of a membrane structure containing the fluid of a specific density is initially unknown and must be calculated before the hydrodynamic analysis. To solve hydrodynamic problem, the fluid domain is divided into the inner and outer region. The inner solution based on discrete membrane dynamic model and simple-source distribution over the entire fluid boundaries is matched to the outer solution ba~ed on an eigenfunction expansion method. The numerical results were compared to a series of Ohyama's experimental results. The measured reflection and tran¬smission coefficients reasonably follow the trend of predicted values. Using the computer program developed, the performance of a bottom-mounted and fluid-filled flexible membrane strocture is tested with various system parameters (membrane shape, internal pressure, density ratio) and wave characteristics (wave frequencies, incident wave angle). It is found that a bottom-mounted and fluid-filled flexible membrane structure can be an effel;tive wave barrier if properly designed.

  • PDF