• Title/Summary/Keyword: Internal loss

Search Result 1,362, Processing Time 0.028 seconds

A Study on the Loss Reduction Method of Reinforcing Bar through Case Study

  • Park, U-Yeol;Jung, Hyeon-Ok;Kang, Tai-Kyung;Cho, Hun-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.123-132
    • /
    • 2010
  • Rebar work accounts for approximately 30% of the total construction costs for rebars and concrete. Recently, the high rising prices of rebars have become one of the principle factors of rising construction costs. Therefore, construction companies are putting much effort into loss reduction of rebars. Consequently, in this study, we wished to present loss reduction methods of rebars before the preparation of the placing drawings. To devise such methods, we collected previous case studies and analyzed methods that were applied for loss reduction. As a result of the analysis, we were able to find the following methods for loss reduction of rebars: method of reducing the number of splices at the mat foundation, method of reducing splice length at the internal columns or walls of the underground parking lot, method of reducing cap-ties of internal beams of basement floors excluding perimeter beams, and method of reducing anchorage length at the internal column or wall of the underground parking lot. Based on those analysis results, we presented our own loss reduction methods of rebars. Applying our methods resulted in considerable loss reduction.

A Reexamination of the Method of Measuring Internal Loss and Quantum Efficiency in Laser Diodes (레이저 다이오드의 내부손실 및 내부 양자효율 측정법에 대한 재고찰)

  • 한영수;도만희;김상배;정상구
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.5
    • /
    • pp.121-125
    • /
    • 1994
  • We examine the conventional method of measuring the internal optical loss using the dependence of the reciprocal external quantum efficiency on the cavity length in laser diodes. It is shown that the implicit assumption of constant internal differential quantum efficiency ${\eta}_{id}$, which has been customarily misinterpreted as internal quantum efficiency ${\eta}_{i}$, is not valid for devices with short cavity length. Therefore, for reliable measurments long cavity data should be used.

  • PDF

In-hospital malnutrition among adult patients in a national referral hospital in Indonesia

  • Dyah Purnamasari;Nur Chandra Bunawan;Dwi Suseno;Ikhwan Rinaldi;Drupadi HS Dillon
    • Nutrition Research and Practice
    • /
    • v.17 no.2
    • /
    • pp.218-227
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: Malnutrition during hospitalization is linked to increased morbidity and mortality, but there are insufficient studies observing clinical factors contributing to weight loss during hospitalization in Indonesia. This study was therefore undertaken to determine the rate of weight loss during hospitalization and the contributing factors. SUBJECTS/METHODS: This was a prospective study involving hospitalized adult patients aged 18-59 yrs, conducted between July and September 2019. Body weight measurement was taken at the time of admission and on the last day of hospitalization. The factors studied were malnutrition at admission (body mass index < 18.5 kg/m2), immobilization, depression (Beck Depression Inventory-II Indonesia), polypharmacy, inflammatory status (neutrophil-lymphocytes ratio; NLR), comorbidity status (Charlson Comorbidity Index; CCI), and length of stay. RESULTS: Totally, 55 patients were included in the final analysis, with a median age of 39 (18-59 yrs) yrs. Of these, 27% had malnutrition at admission, 31% had a CCI score > 2, and 26% had an NLR value of ≥ 9. In all, 62% presented with gastrointestinal symptoms, and depression was documented in one-third of the subjects at admission. Overall, we recorded a mean weight loss of 0.41 kg (P = 0.038) during hospitalization, with significant weight loss observed among patients hospitalized for 7 days or more (P = 0.009). The bivariate analysis revealed that inflammatory status (P = 0.016) was associated with in-hospital weight loss, while the multivariate analysis determined that the contributing factors were length of stay (P < 0.001) and depression (P = 0.019). CONCLUSIONS: We found that inflammatory status of the patient might influence the incidence of weight loss during hospitalization, while depression and length of stay were independent predictors of weight loss during hospitalization.

Transmission Loss Estimation of Three Dimensional Silencers with Perforated Internal Structures Using Multi-domain BEM

  • Ju Hyeon-Don;Lee Shi-Bok
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1568-1575
    • /
    • 2005
  • The calculation of the transmission loss of the silencers with complicated internal structures by the conventional BEM combined with the transfer matrix method is incorrect at best or impossible for 3-dimensional silencers due to its inherent plane wave assumption. On this consideration, we propose an efficient practical means to formulate algebraic overall condensed acoustic equations for the whole acoustic structure, where particle velocities on the domain interface boundaries are unknowns, and the solutions are used later to compute the overall transfer matrix elements, based on the multi-domain BEM data. The transmission loss estimation by the proposed method is tested by comparison with the experimental one on an air suction silencer with perforated internal structures installed in air compressors. The method shows its viability by presenting the reasonably consistent anticipation of the experimental result.

Effects of Hansu-Daebowon (HDW) on RANKL-induced Osteoclast Differentiation and Bone Loss in Mammal Model (한수대보원이 포유동물인 생쥐 모델에서 골 손실 및 RANKL 유도 파골세포 분화에 미치는 영향)

  • Jang, Si-sung;Ryu, Hong-sun;Jeon, Chan-yong;Hwang, Gwi-seo
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.1
    • /
    • pp.58-69
    • /
    • 2019
  • Objective: This study investigated the effects of Hansu-Daebowon (HDW) on bone resorption in vitro and bone loss in vivo. Methods: Osteoclast differentiation was measured by counting TRAP (+) MNC formed from RAW 264.7 in the presence of RANKL. Bone pit formation was determined in an artificial bone slice loaded with RANKL-stimulated osteoclasts. To elucidate the mechanisms of the inhibitory effects of HDW on bone resorption and osteoclast differentiation, osteoclastogenic genes (i.e. TRAP, MMP-9, NFATc1, c-Fos, and Cathepsin K) were measured using real time PCR. Furthermore, bone loss was observed using micro-CT in an LPS-treated mammal model. Results: HDW inhibited the bone pit formation in vitro and inhibited bone loss in vivo. Moreover, HDW decreased the number of TRAP (+) MNCs in the presence of RANKL, and HDW inhibited the expressions of cathepsin K, MMP-9, TRAP, NFATc1, and c-Fos in the osteoclasts. Conclusion: HDW exerts inhibitory effects on bone loss and bone resorption resulting from the inhibitions of osteoclast differentiation and osteoclastogenic gene expression.

A Clinical Study of One Patient Suffering Anorexia Nervosa-like Symptoms (신경성 식욕부진 유사 환자 1례에 대한 증례보고)

  • Kim, Jong-Won;Shim, Jae-Chul;Kim, Min-Sang;Oh, Byeong-Yeol;Lee, Ji- Young;Jo, Hyun-Kyung;Chai, Young;Kim, Yoon-Sik;Seol, In-Chan;Yu, Byeong-Chan
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.655-661
    • /
    • 2004
  • Anorexia nervosa is a serious, often chronic, and life-threatening eating disorder defined by a refusal to maintain minimal body weight (within 15% of an individual s normal weight). Other essential features of this disorder include an intense fear of gaining weight, a distorted body image, and amenorrhea(absence of at least three consecutive menstrual cycles when they are otherwise expected to occur). With anorexia nervosa, the nails and hair become brittle, and the skin may become dry and yellow. In addition to depression, hypothermia, lanugo, nausea, vomiting, anxiety and dehydration from sweating can appear. Starvation, weight loss, and related medical complications are quite serious and can result in death. Recently one patient was admitted with anorexia nervosa-like symptoms. The patient is a 18-year-old girl with complaints of weight loss, amenorrhea, anorexia, nausea, vomiting, tremor, and sweating. After treatment through oriental medicine for 2 weeks, most of the symptoms improved. Therefore, this application of oriental medicine is reported with a plea for further investigation.

  • PDF

Influence of the implant-abutment connection design and diameter on the screw joint stability

  • Shin, Hyon-Mo;Huh, Jung-Bo;Yun, Mi-Jeong;Jeon, Young-Chan;Chang, Brian Myung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.126-132
    • /
    • 2014
  • PURPOSE. This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (${\alpha}$=0.05). RESULTS. The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION. The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

Review on Case Reports of Korean Medical Treatments for Sudden Sensory Neural Hearing Loss (돌발성 난청의 한방치료 치험례에 대한 고찰)

  • Lee, Yu Ri;Kim, Kyung Soon;Choi, Hong Sik;Kim, Seung Mo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.32 no.1
    • /
    • pp.62-69
    • /
    • 2018
  • This study aimed to review case reports of Korean medical treatments for sudden sensory neural hearing loss published in Korea from 1980 to 2016. We searched sudden sensory neural hearing loss through 6 major Korean web article search engines and search period was January 1980 to September 2016. Two researchers included studies on sudden hearing loss, clinical studies on korean medical treatments, and excluded in vivo studies, in vitro studies, non-original studies, published abstracts only, and studies not published in Korean or English. 19 articles were included in this study from 63 articles. Only one case report used Korean medical treatment alone. The most tools for treatment were acupunture, herbal medicine, pharmacopunture, moxibustion, cupping treatment and laser therapy. Most acupoints used in the treatment is SI19(聽宮). When patients got treated sooner, recovery rate was better. There was no direct relationship between recovery rate and degree of hearing loss. This study suggests that more research about sudden sensory neural hearing loss is needed in the future.

Improvement of the Detection of LOB through Reconstruction of an Internal Model (내부 모델의 재구성에 의한 균형상실 검출성능 개선)

  • Kim, Kwang-Hoon;Park, Jung-Hong;Son, Kwon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.9
    • /
    • pp.827-832
    • /
    • 2010
  • Many researchers have tried to detect the falling and to reduce the injury associated with falling. Normally the method of detection of a loss of balance is more efficient than that of a compensatory motion in order to predict the falling. The detection algorithm of the loss of balance was composed of three main parts: parts of processing of measured data, construction of an internal model and detection of the loss of balance. The internal model represented a simple dynamic motion balancing with two rear legs of a four-legged chair and was a simplified model of a central nervous system of a person. The internal model was defined by the experimental data obtained within a fixed time interval, and was applied to the detecting algorithm to the end of the experiment without being changed. The balancing motion controlled by the human brain was improved in process of time because of the experience accruing to the brain from controlling sensory organs. In this study a reconstruction method of the internal model was used in order to improve the success rate and the detecting time of the algorithm and was changed with time the same as the brain did. When using the reconstruction method, the success rate and the detecting time were 95 % and 0.729 sec, respectively and those results were improved by about 7.6 % and 0.25 sec in comparison to the results of the paper of Ahmed and Ashton-Miller. The results showed that the proposed reconstruction method of the internal model was efficient to improve the detecting performance of the algorithm.

Optimization of Design Variables of Detection Algorithm for Loss of Balance Using a Linear Internal Model (균형상실의 검출 성능 향상을 위한 내부 모델의 설계변수 선정 및 민감도 평가)

  • Kim, Kwang-Hoon;Kim, In-Su;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1153-1160
    • /
    • 2010
  • The detection algorithm for loss of balance had three main parts: one for processing data, another for constructing an internal model, and a third for detecting the loss of balance. The part related to the internal model is the most important part of the algorithm. The purpose of this study is to evaluate the effect of variables associated with the internal model on the success rate of the algorithm. The internal model depends on the type of linearization adopted and the operating period of the algorithm. The design variables were evaluated by performing sensitivity analysis of the variables of the internal model in order to obtain the success rate of the algorithm. The results showed that the most sensitive variable was the period and the period of 0.3 s yielded the highest success rate of 97.1%. Further, the ranges of the design variables that can facilitate a success rate of over 95% are presented.