• Title/Summary/Keyword: Internal flow control

Search Result 357, Processing Time 0.032 seconds

Design of Sidewall Ribs for Suppressing Vortex Structures and Reducing Evaporation Rate in Liquid Hydrogen Storage Tank (액체수소 저장용기의 와류 구조 억제 및 증발률 저감을 위한 측벽 rib 설계)

  • Byeonggeon Kim;Hyungi Kim;Yunjeong Park;Mingyu Im;Sungwoo Park;Jinyul Hwang
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.2
    • /
    • pp.11-19
    • /
    • 2024
  • We performed numerical simulations on a C-type liquid hydrogen (LH2) storage tank for commercial vehicles to reduce evaporation rates by manipulating vortical structures. Owing to external heat, natural convection occurs inside the tank, leading to the enhanced evaporation of LH2. We observed that the regions of high magnitude vorticity correlate with those of high evaporation rates. Specifically, vortical structures in the side section area show higher vorticity magnitude and evaporation rates compared to those in the midsection area. To suppress these vortical motions, we installed an array of ribs at intervals corresponding to the mean diameter of the vortical structures. As a result, the area occupied by vortical structures in the side section area decreased, leading to a reduction in evaporation speed by approximately 2.3 times. This study elucidates the internal evaporation mechanism in storage tanks from the perspective of flow structures and potentially contributes to minimizing the boil-off rate in cryogenic storage tanks.

Normal Control Study of Cerebral Blood Flow by Tc-99m HM-PAO SPECT ($^{99m}TC-HMPAO$ SPECT를 이용한 정상인 국소뇌혈류의 정량적 분석)

  • Moon, Dae-Hyuk;Lee, Bum-Woo;Lee, Kyung-Han;Choi, Yoon-Ho;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Yoon, Byung-Woo;Lee, Nam-Soo;Roh, Jae-Kyu;Myung, Ho-Jin;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.155-163
    • /
    • 1989
  • Regional cerebral perfusion was evaluated in 15 normal controls by single photon emission computed tomography using $^{99m}Tc$ HM-PAO. For quantitative analysis, 13 pairs of homologous region of interest (ROI) were drawn on three transverse slices matching the vascular territories and cerebral cortices, and normal values of 3 semiqunatitative indices including 'Right to left ratio'(R/L ratio), 'Regional index'(RI), and 'Region to cerebellum ratio'(R/cbll ratio) were calculated. Mean values of R/L ratios of homotogous regions were ranged from 0.985 to 1.023, and mean ${\pm}2$ s.d. of all regions did not exceed 11% of mean. Significant difference of RIs (mean count per voxel of a ROI/mean count per voxel of total ROIs) between regions were found (p<0.001) with highest values in occipital cortex and cerebellum. After attenuation correction, RIs in deep gray, cranial portion of anterior cerebral artery and vascular territories in the 2nd slice increased significantly (p < 0.05-0.001), but vise versa in other ROIs. Region to cerebellum ratios also showed regional difference similar to RIs.

  • PDF

A Numerical Study of the 2-D Cold Flow for a Qubec City Stoker Incinerator (큐벡시 스토커 소각로 2차원 비반응 유동장 수치해석)

  • 박지영;송은영;장동순
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.268-275
    • /
    • 1993
  • A series of parametric investigations are performed in order to resolve the flow characteristic of a Quebec city stoker incinerator. The parameters considered in this study are five internal configurations of the Quebec city stoker itself and its modified ones, primary air velocity, the injection velocity and angle of the secondary air, and the reduction of the stoker exit area. A control-volume based finite-difference method by Patankar together with the power-law scheme is employed for discretization. The resolution of the pressure-velocity coupling is made by the use of SIMPLEC algorithm. The standard, two equation, k-$\varepsilon$ model is incorporated for the closure of turbulence. The size of recirculation region, turbulent viscosity, the mass fraction of the secondary air and pressure drop are calculated in order to analyze the characteristics of flow field. The results are physically acceptable and discussed in detail. The flow field of the Quebec city stoker shows the strong recirculation zone together with the high turbulence intensity over the upper part of the incinerator.

  • PDF

T-cell Mediated Immunity in Pulmonary and Extrapulmonary Tuberculosis (폐 및 폐외결핵환자에서의 T 림프구 매개성 면역기능의 변화에 관한 연구)

  • Choi, Dong-Chull;Shim, Tae-Sun;Cho, Sang-Heon;Jung, Ki-Ho;Hyun, In-Gyu;Yoo, Chul-Gyu;Kim, Young-Whan;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.1
    • /
    • pp.62-72
    • /
    • 1992
  • Background: T-cell mediated cellular immunity has been suggested as an important mechanism in mycobacterial infection and imbalance between helper/inducer and suppressor/cytotoxic T-cell has been suggested as an important immunological abnormality in the pathogenesis of tuberculosis in human. Method: To determine whether there is any difference in T-cell mediated immunity in the pathogenesis of pulmonary and extra pulmonary tuberculosis, total numbers of WBC&lymphocytes were counted and helper/inducer and suppressor/cytotoxic cells were calculated by flow cytometry. Blastogenesis after stimulation with Concanavalin-A, Phytohemagglutinin and PPD were measured by $^3H$-thymidine uptake. PPD skin test was performed as an in vivo test. Results: 1)There was no significant difference in the size of PPD skin test between pulmonary and extrapulmonary tuberculosis groups. 2)Number of total lymphocytes significantly decreased in tuberculosis patients compared with healthy control group. But there was no significant difference between pulmonary and extrapulmonary tuberculosis groups. 3) Number of HLA-DR and Interleukin-2 receptor (+) cells were significantly increased in tuberculosis patients. But there was no significant difference between pulmonary and extra pulmonary tuberculosis groups. 4) There was no significant difference in the numbers of WBC, $T_3$, $T_4$ and $T_8$ lymphocytes and $T_4/T_8$ ratio between tuberculosis patients and healthy controls. 5) There was no significant difference in the blastogenesis after stimulation with specific and non-specific blastogens between tuberculosis patients and healthy controls. 6) The percentage and absolute number of $T_4$ lymphocyte were significantly correlated with the size of PPD skin test. (r=0.689 and 0.598). Conclusion: From these results, it is concluded that there was no difference in T-cell mediated immunity between pulmonary and extra pulmonary tuberculosis group. But, because it is suspected that there might be some difference in the role of T-cell mediated immunity in the pathogenesis of pulmonary and extra pulmonary tuberculosis or even among the extrapulmonary tuberculosis patients, further studies would be required.

  • PDF

Effect of Samjahwadam-jeon on CD4, CD8 Cells in OVA-induced Asthmatic Mice (삼자화담전(三子化痰煎)이 천식모델 생쥐의 CD4, CD8 세포에 미치는 영향)

  • Nam, Tae-Heung;Park, Yang-Chun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.5
    • /
    • pp.1256-1261
    • /
    • 2008
  • This study aimed to examine the effects of Samjahwadam-jeon (SJHDJ) on $CD4^+$ T cells and $CD8^+$ T cells in ovalbumin (OVA)-induced asthmatic mice. C57BL/6 mice were injected, inhaled and sprayed with OVA for 12 weeks (four a week) for asthma induction. Two experimental groups were treated with different concentrations of SJHDJ (400 mg/kg and 200 mg/kg) extract and cyclosporin A (10 mg/kg) for the later 8 weeks. At the end of the experiment, the mice lung, peripheral lymph node (PLN), and spleen were removed and $CD4^+$ T cells and $CD8^+$ T cells for analyzed by flow cytometer. Number of $CD4^+$ T cells in lung, PLN and spleen of the SJHDJ group (400 mg/kg and 200 mg/kg) were significantly decreased compared with that of control group. Number of $CD8^+$ T cells in PLN and spleen of the SJHDJ group (400 mg/kg, 200 mg/kg) were significantly decreased compared with that of control group. Conclusion: These results suggest that SJHDJ alleviated asthmatic hyperreactivity through $CD4^+$ and $CD8^+$ T cells. Further study of relative cytokines is expected.

Classical Controller Design of Direct Drive Servo Valve Using Analytical Bode Method (해석적 Bode 방법에 의한 직접구동형서보밸브의 고전적 제어기 설계)

  • Lee, S.R.;Choi, H.Y.;Moon, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.507-514
    • /
    • 2001
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the classical controller is designed using the analytical Bode method.

  • PDF

Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method (컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계)

  • Lee, Seong-Rae
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1590-1595
    • /
    • 2003
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

  • PDF

Blast Furnace Modeling for Predicting Cohesive Zone Shape (융착대 예측을 위한 고로공정 모델링)

  • Yang, Kwang-Heok;Choi, Sang-Min;Jung, Jin-Kyung
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.39-45
    • /
    • 2006
  • Analysis of the internal state of the blast furnace is needed to predict and control the operating condition. Especially, it is important to develop modeling of blast furnace for predicting cohesive zone because shape of cohesive zone influences overall operating condition of blast furnace such as gas flow, chemical reactions and temperature. because many previous blast furnace models assumed cohesive zone to be fixed, they can't evaluate change of cohesive zone shape by operation condition such as PCR, blast condition, and production rate. In this study, an axi-symmetric 2-dimensional steady state model is proposed to simulate blast furnace process. In this model, cohesive zone is changed by solid temperature range, FVM is used for numerical simulation. To find location of cohesive zone whole calculation procedure is iterated Until cohesive zone is converged. Through this approach, shape of cohesive zone, velocity, composition and temperature within the furnace are predicted by model.

  • PDF

Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method (컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계)

  • Lee, Seong-Rae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1719-1726
    • /
    • 2004
  • Direct drive servovalve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the DC motor. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

Classical Controller Design of Direct Drive Servo Valve Using Analytical Bode Method (해석적 Bode 방법에 의한 직접구동형서보밸브의 고전적 제어기 설계)

  • Lee, Seong-Rae;Choe, Hyeon-Yeong;Mun, Ui-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.4
    • /
    • pp.754-763
    • /
    • 2002
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the classical controller is designed using the analytical Bode method.