• 제목/요약/키워드: Internal flow control

검색결과 357건 처리시간 0.03초

채널부분의 초전도 자속 흐름 트랜지스터 볼텍스 동력학 (Vortex Dynamics of Superconducting Flux Flow Transistor in a Channel)

  • 고석철;강형곤;임성훈;이종화;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.546-549
    • /
    • 2003
  • The principle of the superconducting vortex flow transistor (SVFT) is based on control of the Abrikosov vortex flowing along a channel. The induced voltage is controlled by a bias current and a control current, instead of external magnetic field. The device is composed of parallel weak links with a nearby current control line. We explained the process to get an I-V characteristic equation and described the method to induce the external and internal magnetic field by the Biot-Savarts law in this paper. The equation can be used to predict the I-V curves for fabricated device. From the equation we demonstrated that the current-voltage characteristics were changed with input parameters. I-V characteristics were simulated to analyze a SVFT with multi-channel by a Matlab program.

  • PDF

An approach for the functional extension of the remote measurement method of unsteady flow rate

  • Yokota, Shin-ichi;Kim, Do-Tae;Suzuki, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.235-239
    • /
    • 1992
  • The paper describes an approach for estimating unsteady flow rate through oil hydraulic pipelines and components in real time. Recently we have proposed following three unsteady flow rate measurement approaches; RIFM, QIFM and TPFM, in which hydraulic pipeline dynamics are made use of. In this paper, we firstly propose new approaches, i.e, an interpolation and an extrapolation methods in combination with RIFM and TPFM. In the interpolation method, unsteady flow rate at the arbitrary internal location along the pipeline between two points for measuring the two point pressure can be estimated. In this paper, the accuracy and dynamic response of interpolation method are mainly experimentally investigated in detail.

  • PDF

실린더 후류를 이용한 2 차원 아음속 디퓨저 유동의 제어에 관한 연구 (A Control of Two-Dimensional Subsonic Diffuser Flow Using the Turbulent Wake Caused by a Cylinder)

  • 김태호;이상찬;윤복현;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.980-985
    • /
    • 2003
  • The present study addresses a computational work to investigate the influence of a turbulent wake flow on the pressure recovery of a subsonic diffuser. The turbulent wake is generated by a cylinder with a small diameter, which is installed at the inlet of a 2-dimensional diffuser. Computation are applied to three-dimensional steady Navier-Stokes equations. The fully implicit finite volume scheme is used to discretize the governing equations. The computational results are qualitatively well compared to the experimental results. The results show that the pressure recovery of the subsonic diffuser is dependent on the diameter and location of cylinder. It is found that a certain diameter and location of the cylinder to generate the turbulent wake give a better pressure recovery, compared with no cylinder flow.

  • PDF

장방형 용기내 자성유체의 Benard유동에 대한 전열 제어 특성에 관한 연구 (A Study on the Heat Transfer Control Characteristics of Benard Flow a Magnetic Fluids in a Rectangular Enclosure)

  • 안종국;서이수;박길문
    • 한국유체기계학회 논문집
    • /
    • 제7권4호
    • /
    • pp.32-39
    • /
    • 2004
  • This study deals with the Benard Flow of Magnetic Fluids in a rectangular cavity which the ratio between height and width is 1 : 4 and the base side or left side is a heating face while other sides are to be cooling faces. When Magnetic field was equally impressed, considering the internal rotation of the elementary ferromagnetic particle, we found the following result from the numerical analysis of the GSMAC algorithm applied to the equation of the magnetic fluid. Benard flow is controlled by intensity and direction of magnetic fields, and critical point appears when especially magnetic field with a heating base and side area near H=-7000 and H=-10000 is applied.

재열기 온도조절 급수배관의 진동저감방안 연구 (A Study on Vibration Control for Reheater Attemperator Piping in Power Plant)

  • 전창빈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1-5
    • /
    • 2007
  • A majority of piping vibration problems are induced by internal fluid pulsation; turbulent flow, vortex shedding at internal discontinuities, and pressure pulsation at equipment nozzles. The pulsation at the pressure sources resonates acoustically with the piping and the amplified pressure pulsation can generate shell mode vibration in the piping. Reheater attemperator piping supplies water from feedwater pump to reheater attemperator to control the boiler temperature. In normal operating condition, the high frequency shell mode vibration occurred in the piping with the high level of sound(105 ${\sim}$ 117 dB). The vibration sources are pressure pulsation in the pump nozzle and the frequencies are related to the blade passing frequencies. The objects of this paper are to analyze the cause of the high frequency vibration and to establish corrective actions.

  • PDF

정적챔버에서 스파크 플러그 이온프로브를 이용한 공연비와 이온신호와의 상관관계에 대한 연구 (A Study on Correlation between A/F and ion signal in a Constant-Volume Chamber Using Spark-plug Ionization Probe Itself)

  • 박종일;전광민;한재원;박철웅
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.223-229
    • /
    • 2002
  • Spark plug ionization signal could be useful in an internal combustion engine as a feedback signal for combustion diagnostics such as misfire detection, knocking detection and lambda control, but the signal has high level of cyclic fluctuation in an internal combustion engine due to residual gas, pressure, temperature, mixture composition in the spark gap. Because of this reason it is very difficult to apply ion signal to commercial engine control. In this Study, a correlation between A/F and spark plug ionization signal was studied in a constant volume chamber. Constant volume chamber with gas phase fuel(Propane) has homogeneous fuel composition , no mixture flow, same pressure and temperature on each test. The results show that mean chemi-ion signal has the highest correlation with A/F and intial pressure change has on effect on the thermal-ion signal and not on chemi-ion signal.

  • PDF

분리벽형 증류탑을 적용한 필름공정의 폐용매 회수공정 최적설계 (Optimal Design of Solvent Recovery Process with Dividing Wall Column for Film Making Process)

  • 이승현;조문신;이문용
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1209-1214
    • /
    • 2006
  • This paper presents an application of Dividing Wall Column(DWC) to the recovery of the waste solvent from the film making processes. The waste solvent feed contains MEK(Methyl-Ethyl-Ketone), Toluene, Cyclohexanone, and water. The commercial software $HYSYS^{TM}$ was used for rigorous simulation and analysis. Sensitivity analysis for several major design variables were carried out to achieve the optimal design of the process. Distribution of the internal vapor and liquid flows to the prefractionator and main sections is shown to be the most dominant design factor for energy saving efficiency in the DWC process. The simulation results also show that the solvent recovery process using the DWC significantly improves both the energy efficiency and the compactness of the solvent recovery process.

내/외재적 유한요소법을 이용한 최대추력노즐의 설계해석 (Implicit/Explicit Finite Element Method for Euler Flows Inside the Optimum Nozzle)

  • 윤웅섭;고현
    • 한국전산유체공학회지
    • /
    • 제2권1호
    • /
    • pp.66-72
    • /
    • 1997
  • Optimum nozzle design exploiting the method of characteristic(M.O.C) has been in application as an efficient design methodology targeting a less weighted and short expansion nozzle. This paper treats the optimum nozzle design and the analysis of the inviscid compressible flow inside. Based on traditional Rao's method, the optimum nozzle design is coded with minor modifications for the identification of the control surface across which the mass flux should be conserved. Internal flow field is simulated numerically by M.O.C and implicit/explicit Taylor-Galerkin finite element method(F.E.M) with the aid of adaptive remeshing to capture the shock wave, hence improve the accuracy. Designed and calculated flow fields due to the separate analyses show that the mass flux predicted by optimum nozzle design with M.O.C is not conserved across the control surface and the sonic line should be located upstream of the nozzle throat. Rao's optimum nozzle design methodology exaggerates the momentum thrust and tends to overemphasize the engine performance loss.

  • PDF

중앙형 추간판탈출증의 진단에서 체열촬영의 의의 (A Study on the Infrared Thermographic Imaging in Diagnosis of the Central Type of Herniated Disc)

  • 송봉근;이종덕;박용현;송운용;김중길
    • Journal of Acupuncture Research
    • /
    • 제15권2호
    • /
    • pp.301-310
    • /
    • 1998
  • Infrared thermographic imaging visualizes noninvasively various abnormal condition by detecting the skin temperature. As the imaging represents the objective condition by the changes in blood flow under the control of autonomic nervous system, it is used to diagnosis and monitor the lumboscral radiculopathy. And asymmetry is important in the diagnosis of disc herniation. The most common type of disc herniation occurs psoterolaterally. This frequently causes nerve root compression leading to a radiculopathy in the distribution of the involved nerve root, most of which also provoke the asymmetric changes in thermography. Central disc herniation, which accounts for 5% to 35% of disc herniation, is typically associated with low back pain. But radiculopathy is usually abscent unless central disc heriniaton is large enough to cause compression of the cauda equina. To evalute the diagnostic value of the thermographic imaging in the diagnosis of central disc herniation, the imaging of 15 normal subjects and 48 patients with central disc herniation documented by CT scan were analyzed. The patients had either bilateral radiculophathy or no radiculopathy. The imaging of patient group with non rediculopathy did not show any significant thermal difference to control. While bilateral radiculopathy group reveled hypothermic pattern compared twith control. Thermal difference between left and right side did not present any significance in non radiculopathy group but hypothermia in bilateral radiculopathy group. Large herniation group demonstrated hyperthemic pattern while the others showed no significant change. Cranial caudal thermal difference did not show any difference between experiment groups. These results shows that infrared thermographic imaging can be used central disc herniation with bilateral radiculopathy, while it seems to little useful on the diagnosis of non radiculopathic disc herniation.

  • PDF

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.