• 제목/요약/키워드: Internal fixation with plate

검색결과 109건 처리시간 0.024초

다발성 외상 환자의 대퇴골 간부 골절에서 임시 외고정술 후 내고정술로의 전환 (Conversion to Internal Fixation after Temporary External Fixation for Femoral Shaft Fractures in Polytrauma Patients)

  • 주석규;강경운;김영우;오형근
    • Journal of Trauma and Injury
    • /
    • 제27권4호
    • /
    • pp.151-157
    • /
    • 2014
  • Purpose: We report the surgical outcomes for femoral shaft fractures in polytrauma patients who were temporarily treated with external fixation and subsequently converted to internal fixation. Methods: From August 2008 to April 2012, we enrolled 13 patients with multiple traumas due to high-energy injuries and concurrent femoral shaft fractures in which temporary external fixation was carried out. The mean age was 39 years, with a range from 18 to 55 years. Ten were men and 3 were women. According to the AO/OTA classification of fractures, type A was found in 5 patients, type B in 6, and type C in 2, with open fractures being found in 6 patients and femoral artery rupture occurring in 2. For internal fixation, intramedullary nailing was performed in 7 patients, and minimally-invasive fixation of locking compression plates was used in 6. Results: Of the 7 patients converted to intramedullary nailing, 1 experienced delayed union. Of the 6 patients treated with minimally-invasive plate fixation, delayed union occurred in 5, and an auto-bone graft was performed within, on average, 8 months (range: 5~10 months), leading to bone union in all cases in the final follow-up. None of the patients experienced infections or complications involving other organs after having been converted to internal fixation. During the mean follow-up of 19 months, patients achieved satisfactory functional outcomes. Conclusion: In polytrauma patients with a femoral shaft fracture who have been treated with temporary external fixation and who may need internal fixation due to the occurrence of delayed union, an appropriate internal fixation method needs to be selected based on the patient's physical status, and the fracture type.

하악골 과두하부 골절 실험모델에서 견고정을 위한 플레이트 고정방법 연구 (Study of the Plating Methods in the Experimental Model of Mandibular Subcondyle Fracture)

  • 이원;강동희
    • 대한두개안면성형외과학회지
    • /
    • 제12권1호
    • /
    • pp.12-16
    • /
    • 2011
  • Purpose: This study examined the biomechanical stability of four different plating techniques in the experimental model of mandibular subcondyle fracture. Methods: Twenty standardized bovine tibia bone samples ($7{\times}1.5{\times}1.0cm$) were used for this study. Each of the four sets of tibia bone was cut to mimic a perpendicular subcondyle fracture in the center area. The osteotomized tibia bone was fixed using one of four different fixation groups (A,B,C,D). The fixation systems included single 2.0 mm 4 hole mini adaption plate (A), single 2.0 mm 4 hole dynamic compression miniplate (B), double fixation with 2.0 mm 4 hole mini adaption plate (C), double fixation with a 2.0 mm 4 hole mini adaption plate and 2.0 mm 4 hole dynamic compression miniplate (D). A bending force was applied to the experimental model using a pressure machine (858 table top system, $MTS^{(R)}$) until failure occurred. The load for permanent deformation, maximum load of failure were measured in the load displacement curve with the chart recorder. Results: Double fixation with a 2.0 mm 4 hole mini adaption plate and a 2.0 mm 4 hole dynamic compression miniplate (D) applied to the anterior and posterior regions of the subcondyle experimental model showed the highest load to failure. Conclusion: From this study, double fixation with an adaption plate and dynamic compression miniplate fixation technique produced the greatest biomechanical stability. This technique may be considered a useful means of fixation to reduce the postoperative internal maxillary fixation period and achieve early mobility of the jaw.

흡수성 망상판과 나사를 이용한 안면골절의 견고정법 (Rigid Fixation using Bioabsorbable Mesh and Screws in Facial Bone Fracture)

  • 신동혁;김덕중;김수영;황은아;최현곤;김순흠;엄기일
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.717-720
    • /
    • 2010
  • Purpose: Absorbable plate and screw fixation is widely used technique for internal rigid fixation in craniomaxillofacial surgery. However, there are some potential problems associated with the use of plate. The purpose of this study is to evaluate the feasibility of bone fixation in facial fracture using absorbable mesh in place of absorbable plate. Methods: The records of 55 patients with zygomaticomaxilla fractures treated by open reduction, performed by the author from February 2008 to May 2009, were retrospectively reviewed. Patients were selected to receive absorbable mesh fixation. The incidence of all complications including infection, hypoesthesia, and deformity was examined. Analysis with postoperative computed tomography follow-up demonstrates degree of reduction. Results: Forty-six patients met criteria for inclusion in the study. All patients went on to satisfactory healing without complication. Postoperative computed tomography revealed good bony alignment similarly non affected side. Conclusion: This study demonstrates that the rigid internal fixation of fractured bone fragments using absorbable mesh is more effective than absorbable plate, especially in comminuted fracture of maxilla.

Clinical Outcome of a Precontoured Symphysis Pubis Plate with Tension Band Wiring for Traumatic Symphysis Pubis Rupture in Pelvic Fractures

  • Lee, Jeong Moon;Yoon, Sun Jung;Park, Myung Sik;Song, Kyung Jin
    • Journal of Trauma and Injury
    • /
    • 제29권1호
    • /
    • pp.22-27
    • /
    • 2016
  • Purpose: The optimal method of fixation of symphysis pubis (SP) diastasis in pelvic ring injuries is still controversial. In this study, we investigated the radiological and the clinical results of a precontoured 4.5-mm symphysis pubis (SP) plate with tension band wiring (TBW) after an anterior pelvic injury in pelvic fractures. Methods: We treated 25 patients with traumatic SP diastasis by open reduction and internal fixation with plates and wires. We used a four-hole 4.5-mm precontoured SP plate with a tension band wiring. Results: Patients with a SP with TBW fixation achieved excellent or good results at final follow-up. Post-operative complications included two (8%) patients with metal work movement. The mean symphyseal width was smaller in 4.5 mm SP plate with TBW during 1-year follow up period. Conclusion: A precontoured symphysis pubis plate (4.5 mm) with figure-of-eight fashion tension band wiring shows favorable radiological results, excellent or good clinical outcome, and a lower complication (hardware failure and revision surgery).

전위된 관절 내 종골 골절의 치료 (Management of Displaced Intra-articular Calcaneal Fracture)

  • 이준영;나웅채
    • 대한족부족관절학회지
    • /
    • 제19권4호
    • /
    • pp.137-141
    • /
    • 2015
  • Recently, open reduction and internal fixation has been the treatment of choice for displaced intra-articular calcaneal fractures for many orthopaedic surgeons. However controversy still surrounds the optimal treatment with regard to whether displaced intra-articular calcaneal fractures should be treated operatively or conservatively. Conservative treatments include use of splint, rest, leg elevation, icing, use of analgesics and early mobilization. Operative treatment is open reduction and internal fixation, performed through an extensile lateral approach with interfragmentary screws and application of a neutralization plate. We reviewed the question of whether operative treatment by open reduction and internal fixation provides a benefit compared with conservative treatment for displaced intra-articular calcaneal fractures.

경골 천정(pilon) 골절의 최신 치료 (Current Treatment of Tibial Pilon Fractures)

  • 이준영
    • 대한족부족관절학회지
    • /
    • 제15권2호
    • /
    • pp.51-57
    • /
    • 2011
  • Pilon fractures involving distal tibia remain one of the most difficult therapeutic challenges that confront the orthopedic surgeons because of associated soft tissue injury is common. To introduce and describe the diagnosis, current treatment, results and complications of the pilon fractures. In initial assessment, the correct evaluation of the fracture type through radiographic checkup and examination of the soft tissue envelope is needed to decide appropriate treatment planning of pilon fractures. Even though Ruedi and Allgower reported 74% good and excellent results with primary open reduction and internal fixation, recently the second staged treatment of pilon fractures is preferred to orthopedic traumatologist because of the soft tissue problem is common after primary open reduction and internal fixation. The components of the first stage are focused primarily on stabilization of the soft tissue envelope. If fibula is fractured, fibular open reduction and internal fixation is integral part of initial management for reducing the majority of tibial deformities. Ankle-spanning temporary external fixator is used to restore limb alignment and displaced intraarticular fragments through ligamentotaxis and distraction. And the second stage, definitive open reduction and internal fixation of the tibial component, is undertaken when the soft tissue injury has resolved and no infection sign is seen on pin site of external fixator. The goals of definitive internal fixation should include absolute stability and interfragmentary compression of reduced articular segments, stable fixation of the articular segment to the tibial diaphysis, and restoration of coronal, transverse, and sagittal plane alignments. The location, rigidity, and kinds of the implants are based on each individual fractures. The conventional plate fixation has more advantages in anatomical reduction of intraarticular fractures than locking compression plate. But it has more complications as infection, delayed union and nonunion. The locking compression plate fixation provides greater stability and lesser wound problem than conventional implants. But the locking compression plate remains poorly defined for intraarticular fractures of the distal tibia. Active, active assisted, passive range of motion of the ankle is recommended when postoperative rehabilitation is started. Splinting with the foot in neutral is continued until suture is removed at the 2~3 weeks and weight bearing is delayed for approximately 12 weeks. The recognition of the soft tissue injury has evolved as a critical component of the management of pilon fractures. At this point, the second staged treatment of pilon fractures is good treatment option because of it is designed to promote recovery of the soft tissue envelope in first stage operation and get a good result in definitive reduction and stabilization of the articular surface and axial alignment in second stage operation.

관절내 종골 골절에 대해 AO 종골 금속판을 이용한 수술적 치료 결과 (Surgical Outcomes of Intra-articular Fractures of Calcaneus using AO Calcaneal Plate)

  • 김성택;윤태현;박진범;이준영
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.75-79
    • /
    • 2009
  • Purpose: To evaluate the outcomes of intra-articular calcaneal fractures treated using AO calcaneal plate surgically. Materails and Methods: Total 15 cases of intra-articular calcaneal fracture that treated with open reduction and internal fixation using AO calcaneal plate were evaluated. The patients were followed over a mean period of 19.8 months. The mean age was 41.6 years. By Sanders classification, there were 2 cases of type II, 10 cases of type III, and 3 cases of type IV. We evaluated radiological outcomes by Bohler angle, Gissane angle, calcaneal hight, calcaneal width and clinical outcomes by Creighton-Nebraska health foundation score. Results: All fractures united at a mean duration of 13.3 weeks. Radiologically, the mean preoperative Bohler angle was $8.5^{\circ}$ and restored to $23.3^{\circ}$. The mean preoperative Gissane angle was $118.7^{\circ}$ and restored to $124.2^{\circ}$. The mean preoperative calcaneal hight was 30.8 mm and restored to 38.9 mm. The mean preoperative calcaneal width was 41.3 mm and restored to 35.3 mm. 10 cases had excellent and good clinical outcomes and 5 cases having fair outcome. Conculsion: In our study, open reduction and internal fixation using AO calcaneal plate showed good results with anatomical restoration of articular surface and stable fixation without late collapse.

  • PDF

Comparison between Accurate Anatomical Reduction and Unsuccessful Reduction with a Remaining Gap after Open Reduction and Plate Fixation of Midshaft Clavicle Fracture

  • Kim, Joon Yub;Choe, Jung Soo;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • 제19권1호
    • /
    • pp.2-7
    • /
    • 2016
  • Background: The purpose of this study is to compare the radiological and clinical outcomes after open reduction and plate fixation of midshaft clavicle fractures between patients who achieved successful anatomical reduction and those who had a remaining fracture gap even after open reduction and plate fixation, and were thus treated with additional demineralized bone matrix (DBM). Methods: This retrospective analysis was conducted on 56 consecutive patients who underwent open reduction and internal fixation using a locking compression plate for acute displaced midshaft clavicle fractures, and who underwent radiographic and clinical outcome evaluations at least 6 months postoperatively. The outcomes between those who achieved perfect anatomical reduction without remnant gap (n=32) and those who had a remaining fracture gap even after open reduction and plate fixation treated with additional DBM (n=24) were evaluated. Results: There were no differences in the use of lag screws or wiring and operation time (all p>0.05) between those with and without remnant gap. No difference in the average radiological union time and clinical outcomes (satisfaction and Constant score) was observed between the two groups (all p>0.05). However, significantly faster union time was observed for AO type A fracture compared with other types (p=0.012), and traffic accident showed association with worse clinical outcomes compared with other causes of injury. Conclusions: Surgical outcome of midshaft clavicle fracture was more affected by initial fracture type and event, and re-reduction and re-fixation of the fracture to obtain a perfect anatomical reduction spending time appears to be unnecessary if rigid fixation is achieved.

송아지에서 발생한 긴뼈골절의 내고정 치료 6례 (Internal Fixation of Long Bone Fractures in 6 Calves)

  • 박진욱;조기래;김중현;최석화;김근형
    • 한국임상수의학회지
    • /
    • 제24권4호
    • /
    • pp.658-662
    • /
    • 2007
  • The simple and easy treatment with cast or splint has been applied to stabilize long bone fractures in farm animals. Applying cast or splint is relatively easier than surgical fixation and may temporarily stabilize fracture site. However, the internal fixation provides strong stabilization and early recovery of limb function. In this report, we describe six cases of limb fractures in calves repaired by internal fixation. Fracture sites are various and affected ages are between 1 day and several months old. In some cases, patients were treated with cast or splint before admitting to Veterinary Medical Center. In these patients, regardless of initial treatment fractures were not immobilized. Consequently we decided to treat these patients with open reduction and internal fixation. The fracture repair with implants(bone plate, screw, cerclage wire, and intramedullary pin) were effective and satisfactory in calves which had been failed by application of cast. Although the cost of orthopedic treatment in farm animal is one of the most important considerations from the practical point of view, internal fixation has many benefits in newborn and young calves. And simplicity of postoperative management is also practically significant benefit expected from infernal fixation In conclusion, we suggest that internal fixation will produce better result than external coaptation in calve.

생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료 (Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures)

  • 권덕주;이용범;신준
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF