• Title/Summary/Keyword: Internal discharge

Search Result 646, Processing Time 0.029 seconds

Risk Factors Associated with Frequent Hospital Readmissions for Exacerbation of COPD

  • Kim, Mi-Hyun;Lee, Kwang-Ha;Kim, Ki-Uk;Park, Hye-Kyung;Jeon, Doo-Soo;Kim, Yun-Seong;Lee, Min-Ki;Park, Soon-Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.4
    • /
    • pp.243-249
    • /
    • 2010
  • Background: Chronic obstructive pulmonary disease (COPD) is one of the leading causes of disability and mortality worldwide. The aim of this study was to evaluate the risk factors associated with recurrent hospital admissions for exacerbation of COPD in Korea. Methods: A retrospective study of 77 consecutive patients hospitalized for exacerbation of COPD at Pusan National University Hospital during the time period January 2005 to May 2008 was performed. The information was collected from the hospitalization period: clinical information, spirometric measures, and laboratory variables. In addition, socioeconomic characteristics, co-morbidity, anxiety, and depression were reviewed. Frequent readmission was defined as 2 or more hospitalizations in the year following discharge. Results: During the 1-year period after discharge, 42 patients (54.6%) reported one hospital admission and 35 patients (45.4%) reported 2 or more hospital readmissions. Among the 35 frequent readmission patients, 4 had more than 10 readmissions. Univariate analysis showed that a body mass index (BMI) <$18.5kg/m^2$, duration >36 months, forced expiratory volume in 1 second ($FEV_1$) <50% predicted, arterial $CO_2$ partial pressure ($PaCO_2$) >40 mm Hg, and arterial oxygen saturation ($SaO_2$) <95% at discharge were associated significantly with frequent readmissions. The multivariate analysis revealed that BMI <$18.5kg/m^2$, $PaCO_2$ >40 mm Hg at discharge were independently associated with frequent readmissions for exacerbation of COPD. Conclusion: Frequent readmissions for exacerbation of COPD were associated with low BMI and hypercapnia at discharge.

The Characteristics of a Superposed Discharge Type Ozonizer with Variation of Mesh in Internal Electrode (내부전극 조밀도 변화에 따른 중첩방전형 오존발생기의 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.87-93
    • /
    • 2005
  • In order to develope high concentration$\cdot$yield ozonizer, superposed discharge type ozonizer using overlap of silent discharge and internal electrode of mesh type has been designed and manufactured. It consists of three electrodes(central electrode, internal electrode and external electrode) and double gaps(gap between central electrode and internal electrode, gap between internal electrode and external electrode). Therefore, ozone is generated by overlapping silent discharges generated between the gaps respectively for which the AC high voltages applied to the internal electrode and the external electrode has a $180{[^\circ]}$ phase difference and for which the central electrode is a ground Ozone generation characteristics proportional to mesh of internal electrode by increasing of discharge electrode and controlling of discharge power density. As a result, the in maximum ozone concentration, generation, and yield can be obtained 17,720[ppm], 5.4[g/h], and 205[g/kwh] respectively.

The Characteristics of Ozone Generation Synergy Effect for 3 Electrode-1 Discharge Gap Silent Discharge Type Ozonizer using Frequency-Vacuum (주파수-진공도를 이용한 3전극-1방전간극 무성방전형 오존발생기의 오존생성 상승 효과 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.94-101
    • /
    • 2005
  • The silent discharge type ozonizer with three electrodes(central electrode, internal electrode, and external electrode) and one discharge gap(discharge gap between internal electrode and external electrode) has been designed and manufactured. It is a silent discharge type ozonizer for which the AC high frequency voltages applied to the central electrode within vacuum discharge tube and the internal electrode for which the external electrode is a ground Ozone is generated by silent discharge in discharge gap. At the moment, discharge characteristics and ozone generation characteristics were investigated in accordance with vacuum of discharge tube, frequency of AC power source, discharge power of ozonizer, and quantity of supplied oxygen gas. In consequence, ozone characteristics proportional to vacuum of discharge tube and frequency of AC power source. The maximum value of ozone can be obtained 7,700[ppm], 460[mg/h] and 70[g/kwh].

A Computational Study for the Discharge Coefficient of a Film-Cooling Hole (Film-Cooling Hole의 유출계수에 관한 수치해석적 연구)

  • 김재형;김희동;박경암
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.2
    • /
    • pp.15-22
    • /
    • 2003
  • Computational study using the 2-dimensional, compressible, Navier-Stokes equations is performed to predict the discharge coefficient of air flow through a film-cooling hole. In order to investigate the effect of internal/external flows on discharge coefficient, the present computational results which are obtained for three flow cases, only external flow, only internal flow, and no flow, are compared with experimental ones. It is found that the computational results predict the discharge coefficient of the film-cooling hole in a reasonable accuracy and the external crossflow reduces the discharge coefficient, while the internal crossflow increases the discharge coefficient in a range of momentum flux ratio $I_{c-jet}$ > 1 due to the total pressure loss and boundary layer effect.

A Patient with a Diagnosis of Spinal Neurofibroma and Complaining of Lower Back Pain: A Case Report, Including Two Follow-ups after Discharge (척추 신경섬유종 진단을 받은 요통 환자에 대한 복합적 한방처치 및 영상학적 경과 관찰 증례 보고 1례)

  • Moon, Heeyoung;Ryu, Gwang-hyun;Ju, Ah-ra;Choi, Yo-sup;Choo, Won-jung;Park, Ji-won;Kim, Doori;Jeon, Yong-hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.5
    • /
    • pp.938-947
    • /
    • 2019
  • Objective: This study was performed to report the changes in symptoms and radiological consequences of a patient diagnosed with spinal neurofibroma and complaining of lower back pain. Methods: The patient was diagnosed with a spinal neurofibroma after MRI examination and was treated with traditional Korean medicine, including traditional Korean medication and acupuncture. We measured the change in symptom severity using a numerical rating scale (NRS) and the Oswestry Disability Index (ODI). We also used the EQ-5D (EuroQoL-5D) scale to assess the patient's quality of life. In addition, we examined the change in the size of the cyst by MRI twice after discharge: at about 3 months after discharge and at about 8 months after discharge. Results: After about 6 weeks of treatment, most pathological symptoms had decreased. The patient showed a decline in NRS and ODI scores and showed an increase in quality of life. The two MRI examinations after the discharge revealed a decrease in the size of the cyst. Conclusions: Traditional Korean medicine can be a solution for patients with spinal neurofibroma causing neurological pain.

Internal pressures in buildings with a dominant opening and background porosity

  • Kim, P.Y.;Ginger, J.D.
    • Wind and Structures
    • /
    • v.16 no.1
    • /
    • pp.47-60
    • /
    • 2013
  • A dominant opening in a windward wall, which generates large internal pressures in a building, is a critical structural design criterion. The internal pressure fluctuations are a function of the dominant opening area size, internal volume size and external pressure at the opening. In addition, many buildings have background leakage, which can attenuate internal pressure fluctuations. This study examines internal pressure in buildings for a range of dominant opening areas, internal volume sizes and background porosities. The effects of background porosity are incorporated into the governing equation. The ratio of the background leakage area $A_L$ to dominant opening area $A_W$ is presented in a non-dimensional format through a parameter, ${\phi}_6-A_L/A_W$. Background porosity was found to attenuate the internal pressure fluctuations when ${\phi}_6$ is larger than 0.2. The dominant opening discharge coefficient, ${\kappa}$ was estimated to lie between 0.05 to 0.40 and the effective background porosity discharge coefficient ${\kappa}^{\prime}_L$, was estimated to be between 0.05 to 0.50.

Development of a New Tooth Profile Designed for High Efficiency P/M Internal Gear Pump Rotors

  • Inui, Naoki;Ogata, Daisuke;Sasaki, Harumistu
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.940-941
    • /
    • 2006
  • We developed a new tooth profile designed for P/M internal gear pump rotors. The theoretical discharge volume of the new tooth profile internal gear rotors is more than 10% higher than that of the same size conventional rotors. Our new profile rotors can achieve a decrease in torque, and fuel-efficiency will also be improved.

  • PDF

Development of Ozone Generation Technology Using Gaseous Electrical Discharge for Environment Improvement (환경개선용 기체전기방전을 이용한 오존발생기술 개발)

  • 이동헌;송현직;구건효
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.25-34
    • /
    • 2001
  • In this paper, discharge lamp ozonizer(DLO) of a new discharge type using superposition of gaseous electrical discharge for environment improvement was designed and manufactured. DLO is equipped with 3 electrodes(central ground electrode of discharge lamp type internal high voltage electrode of mesh type and external high voltage electrode of spiral type), and it is composed of double gap(gap between discharge lamp and internal electrode, gap between discharge lamp and external electrode). Internal and external electrodes are respectively applied AC high voltage which has 180[$^{\circ}$] phase difference. Ozone is generated by overlaying of each silent discharge which is respectively came from two gaps. At the moment discharge characteristics and ozone generation characteristics of DLO were investigated in accordance with quantity of supplied gas, discharge power and the number of DLO. When ozone generated by DLO was in contact with NO gas, removal characteristics was excellent, so it confirmed that DLO could be used as air environment improvement facility.

  • PDF

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • Yang, Sang-Hyeon;Park, No-Jun;Kim, Chung-Sik;Park, Dae-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

Characteristics of Superposed Discharge type Ozonizer by Variation of Inner Dielectric Vacuum

  • Chun, Byung-Joon;Lee, Kwang-Sik;Song, Hyun-Jig
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.230-235
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer with an internal dielectric that can be made into a vacuum tube has been designed and fabricated. Ozone generation and discharge characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of inside internal dielectric. Pure oxygen was used as the supply gas of the ozonizer. Ozone concentration and ozone generation are gradually increased when discharge power is increased at the same flow-rate and they are both proportional to the vacuum level. As such, the maximum ozone concentration of 8840 ppm was obtained at vacuum 0.1 Torr and flow-rate 0.5 $\ell$/min.