A Study on the Evaluation of Mterial Degradaion for 2.25Cr-1Mo Steel using Ultrasonic Attenuation Characterization

  • Kim, Chung-Soek;Park, Ik-Keun;Park, Un-Su;Kim, Hyun-Mook;Kwun, Sook-In;Byeon, Jai-Won
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.319-323
    • /
    • 2001
  • In significant number of energy-related facilities for like thermal power plant or petro-chemical industry, CrMo steels are widely used energy conversion industries. However, these materials undergo precipitation of carbides or intermetallic compounds into grain boundary and change of internal microstructure such as coarsening of precipitation, decrease of solute elements and impurity segregation under more severe service conditions, which results in deterioration of inherent superior material characteristics. In this study, it was verified experimentally the feasibility of the aging degradation evaluation for degraded 2.25Cr-lMo steel specimens prepared by isothermal aging heat treatment at 63$0^{\circ}C$ by high frequency longitudinal ultrasonic and surface SH wave investigating the change of attenuation coefficient analyzed by spectral analysis. Attenuation coefficient had a tendency to increase as degradation proceeded.

  • PDF

소형펀치법에 의한 고온배관재료의 크리프열화 평가 (The Evaluation of Creep Degradation for the High Temperature Pipe Material by Small Punch Test)

  • 유근봉;장성호;송기욱;하정수;김재훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.37-42
    • /
    • 2000
  • The boiler tubes and steam Pipes operating both at high temperature and pressure for a long period of time in a power plant are degraded by creep because of internal pressure. So, the remaining life of a component is evaluated by the creep rupture strength. Although the conventional method to evaluate the creep damage is widely used, it has some disadvantages such as requires large size specimen and long employed to evaluate the correlation between fracture toughness and evaluation time. Recently, new method so called "small lunch test' is used to evaluate degradation of creep. In this study, a conventional creep test and a small punch test are conducted using 2.25Cr-1Mo steel which is mainly used for the boiler tubes and steam pipes in power plant. The creep life, approximately 1,500 hrs, is determined by conventional method under a severe condition then specimens for a small Punch test are obtained after certain time intervals such as 1/4, 1/2 and 3/4 of final rupture time, respectively.

  • PDF

Radiation effect on the polymer-based capacitive relative humidity sensors

  • Shchemerov, I.V.;Legotin, S.A.;Lagov, P.B.;Pavlov, Y.S.;Tapero, K.I.;Petrov, A.S.;Sidelev, A.V.;Stolbunov, V.S.;Kulevoy, T.V.;Letovaltseva, M.E.;Murashev, V.N.;Konovalov, M.P.;Kirilov, V.N.
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2871-2876
    • /
    • 2022
  • The sensitivity of polymer-based capacitive relative humidity (RH) sensors after irradiation with neutrons, electrons and protons was measured. Degradation consists of the decreasing of the upper RH limit that can be measured. At the same time, low RH-level sensitivity is almost stable. After 30 krad of absorption dose, RH cut off is equal to 85% of max value, after 60 krad-40%. Degradation reduces after annealing which indicates high radiation sensitivity of the internal circuit in comparison to RH-sensing polymer film.

전동차용 견인전동기의 가속열화에 의한 전기적 특성 연구 (A Study on the Electrical Characteristics by Accelerating Degradation for Traction Motor in Urban Transit EMU)

  • 박현준;김길동;장동욱;최종선;김정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1235-1237
    • /
    • 2002
  • Insulation system(200 class} for stator coil is designed for traction motor with VVVF inverter. Sample coils for stator of the traction motor were tested by accelerative thermal degradation which composed of heat, vibration, moisture, and overvoltage apply. Reliability and expected life were evaluated on the insulation system for 200 class traction motor. After aging of 10 cycles, tan ${\delta}$ increased with voltage. This result is due to increase of internal defects and change of insulation structure.

  • PDF

견인전동기 고정자 코일의 열화특성 연구 (Research of Degradation Properties on Stator Coil of Traction Motor)

  • 장동욱;변윤섭;왕종배;박현준;김길동;한영재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1430-1432
    • /
    • 2001
  • In this paper, 200-class insulation system for form-wound stator coils is designed for form-wound stator coils is designed for AC traction driven with VVVF inverter. Model coils are made to embody all essential elements representing a winding insulation system and structure. Acceleration degradation for model coils is applied exposure to heat(235$^{\circ}C$). In order to investigate the condition of the coils and to determine their insulation reliability, high voltage test and the dielectric properties such as dielectric loss and capacitance are performed. Also, partial discharge measurement is investigated for internal defects.

  • PDF

차량용 연료전지 스택의 절연열화 진단을 위한 원통형 정전용량-전기전도도 센서개발 (Development of Cylindrical Capacitive-Conductive Sensor to Evaluate Insulating Degradation for FCEV Stack)

  • 김재훈;김주한;김윤형;최강월;한상옥;용기중
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.317-324
    • /
    • 2010
  • It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Consequently it was developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid.

EFFECTS OF TRANSFORMATION CAPACITY ON COMETABOLIC DEGRADATION OF TRICHLOROETHENE

  • Lee, Seung-Bong;Kim, Geon-Ha
    • Environmental Engineering Research
    • /
    • 제10권2호
    • /
    • pp.79-87
    • /
    • 2005
  • The effects of transformation capacity on cometabolic degradation of trichloroethene (TCE) were evaluated using TCE-degrading actinomycetes pure and mixed culture under various culture conditions. The TCE transformation capacity of the actinomycetes enrichment culture in a batch test with phenol addition was 1.0 mg of TCE/mg of volatile suspended solids (VSS). The resting cell TCE transformation capacity of the actinomycetes pure culture cell was 0.75 mg TCE/mg VSS, which increased to 2.0 mg TCE/mg VSS when phenol was added as an external substrate. When the pure culture had an internal substrate in the form of poly-β-hydroxybutyrate (PHB) at 19% of the cell mass, the resting cell TCE transformation capacity increased from 0.47 to 0.6 mg TCE/mg VSS. The presence of PHB increased transformation capacity by 57%, whereas, the addition of phenol caused more than two fold increase in transformation capacity. The actinomycetes culture showed the highest transformation capacity.

내부결함에서 나타나는 전기트리의 부분방전 특성 (PD Characteristic of Electrical Tree Generated by Internal Defects)

  • 김병철;윤재훈;박성희;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1387-1388
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experiment, specimens of electrical tree models were made by three types of XLPE (cross-linked polyethylene). And distribution characteristics of degraded stages are studied too. As a method of detecting and data process, discharge data was acquired from PD detecting system (Biddle instrument). And microscope and digital camera were used to observe the morphologies of the electrical tree to divide stages of the tree. The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

Improving the Stability of Series-Connected Solid Oxide Fuel Cells by Modifying the Electrolyte Composition

  • Kim, Young Je;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권1호
    • /
    • pp.159-165
    • /
    • 2021
  • YSZ based anode supported solid oxide fuel cells (SOFCs) were prepared, and two cells with different electrolyte thicknesses were connected in series for the simulation of a cell-imbalanced fuel cell stack. Pure YSZ cells in a series connection exhibited a rapid degradation when a thick electrolyte cell was operated under a negative voltage. On the other hand, ceria added-YSZ cells in a series connection were stable under similar operating conditions, and the power density and impedance were about the same as those before tests. The improved stability was due to the reduction of internal partial pressure in the electrolyte by locally increasing the electronic conduction. Thus, we propose a new protection method, i.e., the local addition of ceria in the YSZ electrolyte, to extend the lifetime of a cell-imbalanced SOFC stack.

A cost model for determining optimal audit timing with related considerations for accounting data quality enhancement

  • Kim, Kisu
    • 경영과학
    • /
    • 제12권2호
    • /
    • pp.129-146
    • /
    • 1995
  • As society's relience on computerized information systems to support a wide range of activities proliferates, the long recognized importance for adequate data quality becomes imperative. Furthermore, current trends in information systems such as dispersal of the data resource together with its management have increased the difficulty of maintaining suitable levels of data integrity. Especially, the importance of adequate accounting (transaction) data quality has been long recognized and many procedures (extensive and often elaborate checks and controls) to prevent errors in accounting systems have been introduced and developed. Nevertheless, over time, even in the best maintained systems, deficiencies in stored data will develop. In order to maintain the accuracy and reliability of accounting data at certain level, periodic internal checks and error corrections (internal audits) are required as a part of internal control system. In this paper we develop a general data quality degradation (error accumulation ) and cost model for an account in which we have both error occurrences and error amounts and provide a closed form of optimal audit timing in terms of the number of transactions that should occur before an internal audit should be initiated. This paper also considers the cost- effectiveness of various audit types and different error prevention efforts and suggests how to select the most economical audit type and error prevention method.

  • PDF