• Title/Summary/Keyword: Internal check

Search Result 412, Processing Time 0.029 seconds

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

Analysis for Case Study of Quality Management System to Solve Corporate Problems (기업의 문제해결을 위한 품질경영시스템 적용사례 분석)

  • Seo, Suwon;Jeong, Jongpil
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.191-203
    • /
    • 2018
  • Identify the effects of ISO quality management system on the durability of the enterprise by applying it to early startups and small - and medium-sized enterprises. In particular, the quality management system of a technology start-up small and medium sized companies is important in applying the management system to the financial, management and quality control services rather than to research and development. The quality management system is applied to the medical equipment manufacturers, mobile phone brokers, foreign Chinese companies, and components manufacturers for diesel engines.Try it. Check the case where the quality management system has been applied to the company concerned and the nonconformities have been improved. In addition, the success of the project was determined by applying the quality control system to maintain the stability and perpetuation of the company through the case of the failed selection. The company explains that recently, it must appoint internal auditors to carry out continuous improvement activities and that those who want the development and continuity of the company must reflect the quality management system.

Maintenance of Platelet Counts with Low Level QC Materials and the Change in P-LCR according to Hemolysis with XN-9000 (XN-9000장비에서 Low Level QC물질에서의 혈소판 수 관리와 용혈에 따른 P-LCR의 변화)

  • Shim, Moon-Jung;Lee, Hyun-A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.399-405
    • /
    • 2018
  • The platelet count in clinical laboratories is essential for the diagnosis and treatment of hemostasis abnormalities, and accurate platelet counting in the low count range is of prime importance for deciding if a platelet transfusion is needed and for monitoring after chemotherapy. Quality control is designed to reduce and correct any deficiencies in the internal analytical process of a clinical laboratory prior to the release of patient results. Fragmented erythrocytes are the major confusing factors for platelet counting because of their similar size to platelets. The authors found that the low range QC values were out of 2SD with a Sysmex automatic analyzer in internal quality control process. Thus far, there has been little discussion on the relationship between hemolysis and the platelet parameters. Therefore, this study focused on the performance of automated platelet counts, including the PLT-F, the PLT-I, and PLT-O methods at the low platelet range using the low level QC materials and compared the 5 platelet parameters with the hemolyzed samples. The results showed that the CV was the smallest with PLT-F and P-LCR increased from 18.4 to 31.9% in the hemolysis samples. These results indicate that a more accurate estimation of the platelet counts can be achieved using the PLT-F method than the PLT-I method at the low platelet range. The use of the PLT-F system improves the confidence of results in low platelets samples in a routine hematology laboratory. The results suggest that P-LCR is a new parameter in assessing samples when the specimen is suspected of hemolysis and deterioration. Nevertheless, further studies will be needed to establish the relationship with P-LCR and hemolysis using human blood specimens.

A Study of the Reliability and Validity of Standard Tools for the Pattern Identification of Gastroesophageal Reflux Disease (위식도역류질환 변증도구의 신뢰도 및 타당도 평가)

  • Cho, Yun-jae;Ha, Na-Yeon;Ko, Seok-Jae;Park, Jae-Woo;Kim, Jinsung
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.1
    • /
    • pp.1-21
    • /
    • 2022
  • Purpose: The standard tool for the pattern identification is used for identifying patterns in patients using a questionnaire. The purpose of this study is to reorganize the standard tool for the pattern identification of gastroesophageal reflux disease (GERD) developed in 2017 and to analyze the reliability and validity of the standard tool for pattern identification by applying it to GERD patients. Methods: To reorganize the standard tool for the pattern identification of GERD developed in the previous study, we searched the literature in the main databases, OASIS (Oriental Medicine Advanced Searching Integrated System) and CNKI (China National Knowledge Infrastructure). We added the search results to the data used in the previous study and went through the reorganizing courses, such as evaluating the validity of the translation, the Delphi technique, and a small survey. After reorganization, the patients who visited the Kyunghee University Korean Medicine Center for GERD symptoms were provided the questionnaire, including the reorganized standard tool for pattern identification. We analyzed the survey results to evaluate their reliability and validity. Results: Fifty patients completed the questionnaire. Reliability analysis results showed a pattern identification match rate of 86%, Cronbach's α coefficient of 0.834, and intraclass correlation coefficient of 0.907. The Mann - Whitney U test and logistic regression were implemented to check the relations between the survey questions and pattern identification results; the Pearson correlation, compared with other scales, showed a moderate score. Conclusion: We reorganized the standard tool for the pattern identification of GERD to be updated on current issues and so that it is easily used. The analysis results of the questionnaire showed that the reorganized standard tool had high reliability and moderate validity.

Trends and Factors Affecting Participation Rate in Korean National Health Screening among People with Disabilities (우리나라 20세 이상 장애인 건강검진 수검률 추이 및 관련 요인분석)

  • Yun, Ji Eun;Lim, Borami;Ho, Seung Hee
    • Health Policy and Management
    • /
    • v.24 no.2
    • /
    • pp.172-180
    • /
    • 2014
  • Background: People with disabilities have higher prevalence rates and earlier onset of chronic disease than the non-disabled; therefore, their participation in health screening is important. This study evaluates the participation rate and trends in health screening of people with disabilities, and examines the association between their participation rate and disability characteristics, and socioeconomic status. Methods: Data on disability-related characteristics were collected from the National Disability Registry, and participants' corresponding health examination data were taken from the Korean National Health Insurance Corporation between 2002 and 2011. A total of 873,819 participants aged ${\geq}20$ years were analyzed in this study. Results: The rate of participation of people with disabilities in health screening has increased each year, but their participation rate is lower than that of the total population. The participation rate was lower in females than in males; the elderly group than in the younger group; those who live in city areas than rural areas; self-employed for health insurance than employees; those with an internal organ disability than those with an external physical disability; those with a severe disability than those with a mild disability; and those with a short-term disability than for those with a long-term disability. Conclusion: The factors associated with participation rate are age, sex, socioeconomic status, and disability characteristics. These findings indicate that health check-ups of people with disabilities should be promoted using an approach that takes into account the large individual differences in socioeconomic status and disability characteristics in this population.

Microwave Tomography Analysis System for Breast Cancer Detection (전자파 기반 유방암 진단을 위한 토모그램 분석 시스템)

  • Kwon, Ki-Chul;Yoo, Kwan-Hee;Kim, Nam;Son, Seong-Ho;Jeon, Soon-Ik
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.19-26
    • /
    • 2009
  • The microwave exposure device for microwave breast cancer detection consists of RF transceiver and several antennas. The microwave information of object acquired from the microwave exposure device can be calculated permittivity and conductivity by using the inverse scattered analysis. In this paper, we have developed the software for detecting breast cancers based on microwave tomography, by which users not only can check out the existence of breast cancers through the permittivity and conductivity information analysis of the object's internal, but also can analysis easily information for distribution of breast cancers. The developed software provides the function for visualizing the captured permittivity and conductivity information as 2D or 3D color images on which users can easily detect the existence of breast cancers. For more detailed analysis of tomography images, the proposed software also has provided the functions for displaying their cutting profiles as well as position and size information of special area in them.

Production of Porous Metallic Glass Granule by Optimizing Chemical Processing

  • Kim, Song-Yi;Guem, Bo-Kyung;Lee, Min-Ha;Kim, Taek-Soo;Eckert, Jurgen;Kim, Bum-Sung
    • Journal of Powder Materials
    • /
    • v.21 no.4
    • /
    • pp.251-255
    • /
    • 2014
  • In this study, we optimized dissolution the dissolution conditions of porous amorphous powder to have high specific surface area. Porous metallic glass(MG) granules were fabricated by selective phase dissolution, in which brass is removed from a composite powder consisting of MG and 40 vol.% brass. Dissolution was achieved through various concentrations of $H_2SO_4$ and $HNO_3$, with $HNO_3$ proving to have the faster reaction kinetics. Porous powders were analyzed by differential scanning calorimetry to observe crystallization behavior. The Microstructure of milled powder and dissolved powder was analyzed by scanning electron microscope. To check for residual in the dissolved powder after dissolution, energy dispersive X-ray spectroscory and elemental mapping was conducted. It was confirmed that the MG/brass composite powder dissolved in 10% $HNO_3$ produced a porous MG granule with a relatively high specific surface area of $19.60m^2/g$. This proved to be the optimum dissolution condition in which both a porous internal granule structure and amorphous phase were maintained. Consequently, porous MG granules were effectively fabricated and applications of such structures can be expanded.

Study on a 4-Week Recovery Test of Sweet Bee Venom after a 13-Week, Repeated, Intramuscular Dose Toxicity Test in Sprague-Dawley Rats

  • Kang, Hyunmin;Lim, Chungsan;Lee, Seungbae;Kim, Byoungwoo;Kwon, Kirok;Lee, Kwangho
    • Journal of Pharmacopuncture
    • /
    • v.17 no.2
    • /
    • pp.18-26
    • /
    • 2014
  • Objectives: This study was performed to check for reversibility in the changes induced by a 13-week, repeated, dose toxicity test of Sweet Bee Venom (SBV) in Sprague-Dawley (SD) rats. Methods: Fifteen male and 15 female SD rats were treated with 0.28 mg/kg of SBV (high-dosage group) and the same numbers of male and female SD rats were treated with 0.2 mL/kg of normal saline (control group) for 13 weeks. We selected five male and five female SD rats from the high-dosage group and the same numbers of male and female SD rats from the control group, and we observed these rats for four weeks. We conducted body-weight measurements, ophthalmic examinations, urinalyses and hematology, biochemistry, histology tests. Results: (1) Hyperemia and movement disorder were observed in the 13-week, repeated, dose toxicity test, but these symptoms were not observed during the recovery period. (2) The rats in the high-dose group showed no significant changes in weight compared to the control group. (3) No significant differences in the ophthalmic parameters, urine analyses, complete blood cell counts (CBCs), and biochemistry were observed among the recovery groups. (4) No changes in organ weights were observed during the recovery period. (5) Histological examination of the thigh muscle indicated cell infiltration, inflammation, degeneration, necrosis of muscle fiber, and fibrosis during the treatment period, but these changes were not observed during the recovery period. The fatty liver change that was observed during the toxicity test was not observed during the recovery period. No other organ abnormalities were observed. Conclusion: The changes that occurred during the 13-week, repeated, dose toxicity test are reversible, and SBV can be safely used as a treatment modality.

Design and Development of Network for Housing Estate Security System

  • Nachin, Awacharin;Mitatha, Somsak;Dejhan, Kobchai;Kirdpipat, Patchanon;Miyanaga, Yoshikazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1480-1484
    • /
    • 2003
  • This paper presents the design and development of network for housing estate security system. The system can cover up to 961 houses which can be up to 1,200 meters long transfer rate of 9,600 bps. This system uses checking and warning the abnormal situation. More over this system has ability to control switch on/off the electrical equipment in the house via AC line control system. The system consists of 4 parts. The first part is a security system of each house using MCS-51 microcontroller as a central processing unit scan 32 sensors and control 8 appliances and send alarm. The MCS-51 microcontroller received control signal via telephone used DTMF circuit. The second part is distributed two levels master/slave network implementing after RS-485 serial communication standard. The protocol its base on the OSI (Open Systems Interconnection) 7 layers protocol model design focus on speed, reliability and security of data that is transferred. The network security using encrypt by DES algorithm, message sequence, time stamp checking and authentication system when user to access and when connect new device to this system. Flow control in system is Poll/Select and Stop-and-Wait method. The third part is central server that using microcomputer which its main function are storing event data into database and can check history event. The final part is internet system which users can access their own homes via the Internet. This web service is based on a combination of SOAP, HTTP and TCP/IP protocols. Messages are exchanged using XML format [6]. In order to save the number of IP address, the system uses 1 IP address for the whole village in which all homes and appliance in this village are addressed using internal identification numbers. This proposed system gives the data transfer accuracy over 99.8% and maximum polling time is 1,120 ms.

  • PDF

Evaluation of EM Susceptibility of an PLL on Power Domain Networks of Various Printed Circuit Boards (다양한 PCB의 전원 분배 망에서의 PLL의 전자기 내성 검증)

  • Hwang, Won-Jun;Wee, Jae-Kyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.74-82
    • /
    • 2015
  • As the complexity of an electronic device and the reduction of its operating voltage is progressing, susceptibility test of the chip and module for internal or external noises is essential. Although the immunity compliance of the chip was served with IEC 62132-4 Direct Power Injection method as an industry standard, in fact, EM immunity of the chip is influenced by their Power Domain Network (PDN). This paper evaluates the EM noise tolerance of a PLL and compares their noise transfer characteristics to the PLL on various PCB boards. To make differences of the PDNs of PCBs, various PCBs with or without LDO and with several types of capacitors are tested. For evaluation of discrepancies between EM characteristics of an IC only and the IC on real boards, the analysis of the noise transfer characteristics according to the PDNs shows that it gives important information for the design having robust EM characteristics. DPI measurement results show that greatly improved immunity of the PLL in the low-frequency region according to using the LDO and a frequency change of the PLL according to the DPI could also check with TEM cell measurement spectrum.