• Title/Summary/Keyword: Internal Response

Search Result 1,975, Processing Time 0.033 seconds

A Basic Study of the European Side Impact Characteristics of Electric Vehicle(II) (전기자동차의 유럽 측면 충돌 특성 기초 연구(II))

  • 조용범;신효철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.143-152
    • /
    • 2002
  • European side impact analysis of an electric vehicle was done using the robust design method. In order to minimize VC as well as rib deflection, the injury response table which consists of rib deflection and VC response table has been introduced. The sensitivities and interactions are almost the same when it was compared with those of rib deflection and VC response table. Using internal energy of the factors, the starting time of dummy rib deflection and the contact average velocity, the internal energy and time-velocity response table were introduced. It is shown that the results of the new response tables have the similar characteristics to those of the Injury response table. It is suggested that the internal energy and time-velocity response table should be utilized to minimize injuries.

Structural Integrity Assessment of the Internal Structure (원전 기기 내부구조물에 대한 구조건전성평가)

  • Lee, Han-Hee;Choi, Jin-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3497-3500
    • /
    • 2007
  • The internal structure is subjected to dynamic analysis due to the structural integrity. The internal structure shall be installed in the vertical hole call IR1 of reactor core. In order to verify the deflection of the internal structure, the mode and response spectrum analysis of the internal structure was performed. The natural frequency of the internal structure is 11.6 Hz(mode 1 and 2) and deflections of the internal structure are less than values of allowable design (3.2 mm).

  • PDF

Seismic responses of hyperbolic cooling towers under horizontal and vertical earthquake

  • Zhang, Jun-Feng;Wang, Yuan-Hao;Li, Jie;Zhao, Lin
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.405-415
    • /
    • 2021
  • Following the dynamic property analysis and elaboration, linear response spectrum analysis (RSA) and response history analysis (RHA) were conducted on a representative hyperbolic cooling towers (HCT) in present study. The seismic responses in tower shell were illustrated in detail, including the internal force amplitude, modal contribution, influence from damping ratio, comparison of results got from RSA and RHA and especially the latitude distributions of internal forces. The results show that the eigenmodes could be classified in a new method into four types according to their mode shapes and only the lateral bending modes and vertical stretching modes are meaningful for horizontal and vertical earthquake correspondingly. The bending modes and seismic deformation display the same feature which is global lateral bending accompanied by minute circular flow displacement of section. This feature also decides the latitude distributions of internal forces as sine or cosine. Moreover, the following method is also proposed for approximate estimation of internal force amplitudes without time-consuming response history analysis: getting the response spectrums of the selected ground accelerations and then comparing values of response spectrums at the natural period of first lateral bending mode because it is always prime dominant for horizontal seismic responses.

Influence of Building Base-Isolation on Seismic Response of Submerged Internal Systems (건물기초의 절연이 내부수중구조물의 지진응답에 미치는 영향)

  • 신태명
    • Computational Structural Engineering
    • /
    • v.9 no.3
    • /
    • pp.125-134
    • /
    • 1996
  • The base-isolation of building, as appeared in many studies, has shown remarkable performance in seismic response attenuation of the internal system as well as the building structure itself. But for the case that the internal system is submerged and hence subject to a considerable hydrodynamic effect, the seismic response of the system due to the base-isolation of building can be greater than the case that they are in air. This paper presents the dynamic analysis of a submerged internal system on base-isolated building to show such an example. The results show that an additional treatment is required to reduce the adverse effects on the seismic response of such a system when the building is base-isolated, and that the system response can be reduced to some extent by an appropriate control of fluid gap between the system and the building structure.

  • PDF

Comparison of Metabolic and Anatomic Response to Chemotherapy Based on PERCIST and RECIST in Patients with Advanced Stage Non-small Cell Lung Cancer

  • Ordu, Cetin;Selcuk, Nalan A.;Akosman, Cengiz;Eren, Orhan Onder;Altunok, Elif C.;Toklu, Turkay;Oyan, Basak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.321-326
    • /
    • 2015
  • Background: The aim of this study was to explore the prognostic role of metabolic response to chemotherapy, determined by FDG-PET, in patients with metastatic non-small-cell lung cancer (NSCLC). Materials and Methods: Thirty patients with metastatic NSCLC were analyzed for prognostic factors related to overall survival (OS) and progression free survival (PFS). Disease evaluation was conducted with FDG-PET/CT and contrast-enhanced CT prior to and at the end of first-line chemotherapy. Response evaluation of 19 of 30 patients was also performed after 2-3 cycles of chemotherapy. Morphological and metabolic responses were assessed according to RECIST and PERCIST, respectively. Results: The median OS and PFS were 11 months and 6.2 months, respectively. At the end of first-line chemotherapy, 10 patients achieved metabolic and anatomic responses. Of the 19 patients who had an interim response analysis after 2-3 cycles of chemotherapy, 3 achieved an anatomic response, while 9 achieved a metabolic response. In univariate analyses, favorable prognostic factors for OS were number of cycles of first-line chemotherapy, and achieving a response to chemotherapy at completion of therapy according to the PERCIST and RECIST. The OS of patients with a metabolic response after 2-3 cycles of chemotherapy was also significantly extended. Anatomic response at interim analysis did not predict OS, probably due to few patients with anatomic response. In multivariate analyses, metabolic response after completion of therapy was an independent prognostic factor for OS. Conclusions: Metabolic response is at least as effective as anatomic response in predicting survival. Metabolic response may be an earlier predictive factor for treatment response and OS in NSCLC patients.

The Effect of the Perceived Physical Environments of Hotel Kitchens on Cooking Employees' Internal Responses (호텔 주방의 지각된 물리적 환경이 조리 종사자의 내적 반응에 미치는 영향)

  • Heo, Jun;Yoo, Taek-Yong
    • Culinary science and hospitality research
    • /
    • v.14 no.4
    • /
    • pp.217-231
    • /
    • 2008
  • The purpose of this study is to examine how the perceived physical environments of hotel kitchens influence cooking employees' internal responses. According to the analysis results of this study, except Hypothesis 2 which was rejected in this study, all the hypotheses were partially accepted. These results support the research hypotheses of this study that comfort, spatiality, and convenience as physical environments will have significant effects on emotional response and cognitive response. Also, equipment use as convenience had statistically significant effects on both emotional response and cognitive response whereas working environment as comfort and kitchen circulation and working space as spatiality had no effect. Therefore, kitchen environment should be set up in the direction of guaranteeing kitchen convenience to the maximum, and the further researches on the constituent factors which have no effect on emotional response and cognitive response should be proceeded continuously.

  • PDF

Characteristics of wind loading on internal surface and its effect on wind-induced responses of a super-large natural-draught cooling tower

  • Zou, Yun-feng;Fu, Zheng-yi;He, Xu-hui;Jing, Hai-quan;Li, Ling-yao;Niu, Hua-wei;Chen, Zheng-qing
    • Wind and Structures
    • /
    • v.29 no.4
    • /
    • pp.235-246
    • /
    • 2019
  • Wind loading is one of important loadings that should be considered in the design of large hyperbolic natural-draught cooling towers. Both external and internal surfaces of cooling tower are under the action of wind loading for cooling circulating water. In the previous studies, the wind loads on the external surface attracted concernedly attention, while the study on the internal surface was relatively ware. In the present study, the wind pressure on the internal surface of a 220 m high cooling tower is measured through wind tunnel testing, and the effect of ventilation rate of the packing layer on internal pressure is a major concern. The characteristics of internal wind pressure distribution and its effect on wind-induced responses calculated by finite element method are investigated. The results indicate that the wind loading on internal surface of the cooling tower behaves remarkable three-dimensional effect, and the pressure coefficient varies along both of height and circumferential directions. The non-uniformity is particularly strong during the construction stage. Analysis results of the effect of internal pressure on wind-induced responses show that the size and distribution characteristics of internal pressure will have some influence on wind-induced response, however, the outer pressure plays a dominant role in the wind-induced response of cooling tower, and the contribution of internal pressure to the response is small.

Frequency analysis of beams with multiple dampers via exact generalized functions

  • Failla, Giuseppe
    • Coupled systems mechanics
    • /
    • v.5 no.2
    • /
    • pp.157-190
    • /
    • 2016
  • This paper deals with frequency analysis of Euler-Bernoulli beams carrying an arbitrary number of Kelvin-Voigt viscoelastic dampers, subjected to harmonic loads. Multiple external/internal dampers occurring at the same position along the beam axis, modeling external damping devices and internal damping due to damage or imperfect connections, are considered. The challenge is to handle simultaneous discontinuities of the response, in particular bending-moment/rotation discontinuities at the location of external/internal rotational dampers, shear-force/deflection discontinuities at the location of external/internal translational dampers. Following a generalized function approach, the paper will show that exact closed-form expressions of the frequency response under point/polynomial loads can readily be derived, for any number of dampers. Also, the exact dynamic stiffness matrix and load vector of the beam will be built in a closed analytical form, to be used in a standard assemblage procedure for exact frequency response analysis of frames.

Internal Control and Stock Price Informativeness about Future Earnings (내부통제와 미래이익에 대한 주가 정보성)

  • Wanglan;Hee-woo Park
    • Asia-Pacific Journal of Business
    • /
    • v.14 no.4
    • /
    • pp.255-273
    • /
    • 2023
  • Purpose - This study examines whether internal control has an effect on stock price informativeness about future earnings. High quality internal control provides continuous assurance for the quality of financial reports, and these future earnings-related information is accurately reflected in the current stock price. Design/methodology/approach - This study collected 12,862 data from 2006 to 2021 in China to make an empirical analysis using the future earnings response coefficient (FERC) and the multiple regression analysis were hired in order to analyze the data. Findings - We find that internal control strengthens the association between current returns and future earnings, indicating that more information about future earnings is reflected in current stock prices. This positive effect exists in both the main board market and the growth enterprise market of China's stock market, especially in the main board market after the implementation of the internal control policy. In addition, we find that the positive effect is weaker for firms that report internal control deficiencies or receives non unqualified internal control audit opinions. The results using earnings persistence yield similar findings, further supporting the results based on the FERC model. Research Implications or Originality - Our tests provide strong evidence that the quality of internal control affects FERC in China stock market.

Female Gender is a Poor Predictive Factor of Functional Dyspepsia Resolution after Helicobacter pylori Eradication: A Prospective, Multi-center Korean Trial (기능성 소화불량증 환자에서 헬리코박터 파일로리 제균 치료 효과 및 관련 요인: 국내 전향적, 다기관 연구)

  • Kim, Sung Eun;Kim, Nayoung;Park, Seon Mee;Kim, Won Hee;Baik, Gwang Ho;Jo, Yunju;Park, Kyung Sik;Lee, Ju Yup;Shim, Ki-Nam;Kim, Gwang Ha;Lee, Bong Eun;Hong, Su Jin;Park, Seon-Young;Choi, Suck Chei;Oh, Jung Hwan;Kim, Hyun Jin
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.6
    • /
    • pp.286-294
    • /
    • 2018
  • Background/Aims: The predictive factors of functional dyspepsia (FD) remain controversial. Therefore, we sought to investigate symptom responses in FD patients after Helicobacter pylori (H. pylori) eradication and used predictive factor analysis to identify significant factors of FD resolution at one-year after commencing eradication therapy. Methods: This prospective, multi-center clinical trial was performed on 65 FD patients that met Rome III criteria and had H. pylori infection. Symptom responses and factors that predicted poor response were determined by analysis one year after commencing H. pylori eradication therapy. Results: A total of 63 patients completed the one-year follow-up. When an eradication success group (n=60) and an eradication failure group (n=3) were compared with respect to FD response rate at one year, results were as follows; complete response 73.3% and 0.0%, satisfactory response 1.7% and 0.0%, partial response 10.0% and 33.3%, and refractory response 15.0% and 66.7%, respectively (p=0.013). Univariate analysis showed persistent H. pylori infection (p=0.021), female gender (p=0.025), and medication for FD during the study period (p=0.013) were associated with poor FD response at one year. However, age, smoking, alcohol consumption, and underlying disease were not found to affect response. Finally, multivariate analysis showed that female gender (OR, 4.70; 95% CI, 1.17-18.88) was the sole independent risk factor of poor FD response at one year after commencing H. pylori eradication therapy. Conclusions: Female gender was found to predict poor response in FD patients despite H. pylori eradication. Furthermore, successful H. pylori eradication appears to be associated with FD improvement, but the number of non-eradicated patients was too small to conclude.