Influence of Building Base-Isolation on Seismic Response of Submerged Internal Systems

건물기초의 절연이 내부수중구조물의 지진응답에 미치는 영향

  • 신태명 (한국원자력연구소 운전기계분야)
  • Published : 1996.09.01

Abstract

The base-isolation of building, as appeared in many studies, has shown remarkable performance in seismic response attenuation of the internal system as well as the building structure itself. But for the case that the internal system is submerged and hence subject to a considerable hydrodynamic effect, the seismic response of the system due to the base-isolation of building can be greater than the case that they are in air. This paper presents the dynamic analysis of a submerged internal system on base-isolated building to show such an example. The results show that an additional treatment is required to reduce the adverse effects on the seismic response of such a system when the building is base-isolated, and that the system response can be reduced to some extent by an appropriate control of fluid gap between the system and the building structure.

건물기초를 지진절연하면 건물뿐만 아니라 그 내부구조물의 지진응답도 크게 감소한다는 사실이 많은 연구를 통해 확인되어 왔다. 그런데 이러한 내부구조물이 유체내에 잠기고 부가질량효과가 크게 작용되는 조건에 놓이는 경우 오히려 지진응답이 증가할 수 있다. 본 논문은 건물 내 수중구조물의 지진해석을 통해 그러한 예를 제시하고자 한다. 해석결과 지진절연된 건물의 경우 이러한 내부 수중구조물의 지진응답이 상당히 증가할 수 있기 때문에 이에 대한 조치가 필요함을 보였고, 적절한 설계에 의하여 부가질량효과를 조절함으로써 어느정도 응답을 줄일 수 있다는 사실을 알 수 있었다.

Keywords

References

  1. Nucl. Eng. and Design v.127 Seismic Isolation of Nuclear Power Plants Coladant, C.
  2. Report No. UCB/EERC-81/17, Earthquake Engineering Research Center The influence of base isolation on the seismic response of light secondary equipment Kelly, J.M.
  3. Earthquake eng. struct. dyn. v.13 Seismic response of light internal equipment in base-isolated structures Tsai, H.C.;Kelly, J.M.
  4. Earthquake eng. struct. dyn. v.19 Floor response spectra for base-isolated multi-storey structures Fan, F.G.;Ahmadi, G.
  5. Eng. Struct. v.14 Seismic response of secondary systems in base-isolated structures Fan, F.G.;Ahmadi, G.
  6. J. eng. ind. Trans. ASME The effect of liquids on the dynamic motions of immersed solids Fritz, R.J.
  7. ASME PVP-39 Dynamic fluid-structure coupling of rectangular pools Scavuzzo, R.J.;Stokey, W.F.;Radke, E. F.
  8. J. app. mech. v.98 Added mass and damping of a vibrating rod in confined viscous fluids Chen, S.S.;Wambsganss, M.W.;Jendrzejczyk, J.A.
  9. J. Str. Div. ST5 Size effect in damping caused by water submersion Dong, R.G.
  10. 3rd Symposium on Current Issues Related to NPP Structures, Equipment and Piping v.V.4-1-V/ Structural evaluations of onsite spent fuel storage : recent developments Singh, S.;Putman, S.F.;Pop. J.