• Title/Summary/Keyword: Internal Performance

Search Result 3,830, Processing Time 0.041 seconds

Measurement of Formaldehyde in the Atmosphere using a Dual-channel Glass Coil Sampler (이중 채널 유리코일 샘플러를 이용한 대기 중 포름알데하이드 측정)

  • Park Seung-Shik;Hong Sang-Bum;Lee Jai-Hoon;Cho Sung-Yong;Kim Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.259-266
    • /
    • 2006
  • A dual-channel glass coil sampling technique was used to measure hourly formaldehyde concentration in the ambient air. The dual-channel coil sampling assembly consists of three parts; an all-pyrex 28-turn coil made of 0.2-cm internal diameter glass tubing for gas-liquid contact and scrubbing of soluble gases, an inlet section upstream of the coil for introducing sample air and scrubbing solution, and a widened glass section downstream of the coil for gas-liquid separation. The scrubbing solution used was a dilute aqueous DNPH (dinitrophenylhydrazine) solution. Hourly concentration of formaldehyde was determined at a Gwangju semi-urban site during two intensive studies between September and October using the dual channel glass-coil/DNPH sampling technique and HPLC (High Performance Liquid Chromatography) analysis. The mean concentration was 1.7($0.4{\sim}4.7$) and 3.0($0.5{\sim}19.1$) ppbv for the September and October intensives, respectively, which are considerably low, compared to those measured in polluted urban areas around the world including several urban areas of Korea. The diurnal variation showed significant increase of formaldehyde in the daytime suggesting the dominance of formation of formaldehyde due to photochemical oxidation of methane and other hydrocarbons. An increase in the formaldehyde sometimes in the night might be due to an increase in primary source, i.e. traffic emissions. It was also found that rapid increase in formaldehyde levels from 3.0 to 19.1 ppbv in the afternoon on October 20 was due to plumes from burning of agricultural wastes such as rice straw and stubble. It is expected from the measurement data that the constructed dual-channel glass coil sampling system can be utilized for measuring atmospheric concentration of the formaldehyde with high time resolution.

Implementation of an operation module for an integrated network management system of ship-based and offshore plants (해양플랜트 및 선박의 네트워크 통합 관리 시스템 운용 모듈 개발)

  • Kang, Nam-Seon;Lee, Seon-Ho;Lee, Beom-Seok;Kim, Yong-Dae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.613-621
    • /
    • 2016
  • This research connected network equipment, including CCTV, PAGA, IP-PBX, and Legacy, in order to enable the operation and configuration of internal IP-based network equipment in maritime plants and vessels, both in the field and from remote places, and to allow for the support of remotely controlling such equipment. It also realized an operating program for the integrated network equipment management system to enable the monitoring and control of equipment status, operation condition, and notifications from distant places. By applying the operating program to satellite stations and vessels sailing on the sea, a performance test was conducted to evaluate data loss and transmission/reception delay in the communication section between the land and vessels. As a result, this research verified the normal operation of CCTV control and of real-time monitoring and control of the network equipment, including PAGA, IP-PBX, and Legacy under the FBB and MVSAT environments. It was observed that the transmission of CCTV video images with a large volume of data as well as the transmission and reception of voice data were found to be slightly delayed, indicating the need to develop technology to compress and convert data for real-time transmission and reception.

A Logical Cell-Based Approach for Robot Component Repositories (논리적 셀 기반의 로봇 소프트웨어 컴포넌트 저장소)

  • Koo, Hyung-Min;Ko, In-Young
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.8
    • /
    • pp.731-742
    • /
    • 2007
  • Self-growing software is a software system that has the capability of evolving its functionalities and configurations by itself based on dynamically monitored situations. Self-growing software is especially necessary for intelligent service robots, which must have the capability to monitor their surrounding environments and provide appropriate behaviors for human users. However, it is hard to anticipate all situations that robots face with, and it is hard to make robots have all functionalities for various environments. In addition, robots have limited internal capacity. To support self-growing software for intelligent service robots, we are developing a cell-based distributed repository system that allows robots and developers transparently to share robot functionalities. To accomplish the creation of evolutionary repositories, we invented the concept of a cell, which is a logical group of distributed repositories based upon the functionalities of components. In addition, a cell can be used as a unit for the evolutionary growth of the components within the repositories. In this paper, we describe the requirements and architecture of the cell-based repository system for self-growing software. We also present a prototype implementation and experiment of the repository system. Through the cell-based repositories, we achieve improved performance of self-growing actions for robots and efficient sharing of components among robots and developers.

Factors Affecting the Organizational Citizenship Behaviors of Administrative Hospital Staff Members (종합병원 행정직원의 조직시민행동 영향요인)

  • Park, Jung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.539-547
    • /
    • 2017
  • This paper reports the results of descriptive research aimed at determining the effects of the administrative hospital staff members' organization-based self-esteem and work engagement on their organizational citizenship behaviors. The participants of the study were 200 administrative staff members of general hospitals, each with 200 beds or more, located in B city. Data were collected from March 15 to 30, 2017, and analyzed statistically using a t-test, ANOVA, Pearson's correlation coefficient, and multiple regression analysis. The findings of this study can be summarized as follows. The organizational citizenship behaviors differed significantly according to whether they had an experience of turnover (t=-4.260, p=.000) and how long they had served at their present work (t=3.297, p=.039). In addition, the organizational citizenship behaviors had strong positive correlations with the organization-based self-esteem (r=.454, p=<.000) and work engagement (r=.595, p<.000). In addition, the factor that explained the organizational citizenship behaviors most significantly was work engagement, followed by organization-based self-esteem and the period of service at the present work. All three factors accounted for 41% of those behaviors. These findings suggest that the hospital should perform internal marketing or improve its welfare system to make administrative staff members raise their self-esteem based on their organization. Moreover, the hospital should form an organizational culture of its own, in which administrative staff members feel the importance of their job, enjoy it and are given autonomy in job performance, ultimately contributing to the development of hospital management.

Numerical Analysis of Heat Transfer Characteristics of Ribbed Channels with Different Film Cooling Hole Position (필름 냉각을 위한 리브드 채널의 홀 위치에 따른 열전달 특성 수치 해석)

  • Park, Jee Min;Moon, Joo Hyun;Lee, Hyung Ju;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.69-76
    • /
    • 2018
  • The present study analyzed the effect of film hole position of 45 degree ribbed cooling channel on film cooling performance of gas turbine blades. We also investigated the influence of the ribs under the fixed blowing ratio. Three-dimensional numerical model was constructed and extensive simulation was conducted using the commercial code (Fluent ver. 17.0) under steady-state condition. Base on the simulation results, We investigated the cooling effectiveness, flow velocity, streamline, and pressure coefficient. Moreover, We analyzed the effect of cooling hole position on ejection of the secondary flow caused by the rib structure. From the results, It was found that internal flow of the cooling channel forms a vortex pair in the counterclockwise from the top side, and clockwise from the bottom side. For the channels with ribs, the vortex flow generated by the ribs caused a higher pressure difference near the hole outlet, resulting in at least 12% higher cooling effectiveness than the channel without ribs. Additionally, when the hole is located on the left side of the ribbed channel (Rib-Left), it can be found that the secondary flow generated by the ribs hits against wall surface near the hole to form a flow in the direction of the hole inclination angle. Therefore, It is considered that the region where the cooling gas discharged to the blade surface stays in the main flow boundary layer is wider than the other cases. In this case, The largest pressure coefficient difference was observed near the outlet of the hole, and as a result, the discharge of the cooling gas was accelerated and the cooling efficiency was slightly increased.

Numerical Study on Shotcrete Lining with Steel Reinforcement Using a Fiber Section Element (화이버 단면 요소를 이용한 강재 보강된 숏크리트 라이닝의 수치해석적 연구)

  • Kim, Jeong Soo;Yu, Jee Hwan;Kim, Moon Kyum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.919-930
    • /
    • 2014
  • In this study, the load capacities and behaviors of a shotcrete member with steel supports, as composite member, are investigated numerically by using a fiber section element. The cross section of a shotcrete lining with steel support is divided into a bundle of fibers, which are allocated nonlinear stress-strain relations and used for determining internal forces. To verify the used approach of the finite element method for shotcrete with steel supports, the load-displacement relations of shotcrete lining obtained by numerical analysis are compared with existing experimental results and are analyzed with the stress distribution of the shotcrete and steel support obtained numerically. As a result, it is shown that the proposed approach can predict the load capacities of each material and the overall nonlinear behavior of shotcrete lining with steel supports. The change of location of the neutral axis and the flexural resistance ratio of each material are also derived from the stress distribution of the cross section of the shotcrete lining with steel supports. From the results, it is concluded that the flexural resistance performance of steel support should be considered in shotcrete lining design.

Experimental Verification of Implantable Middle Ear System using the Differential Electromagnetic Type Transducer (차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 실험적 검증)

  • 송병섭;이기찬;원철호;박세광;이상흔;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.217-225
    • /
    • 2002
  • The implantable middle ear(IME) system, which has good sound quality. superior sound intelligibility and wide frequency characteristics. can resolve the sound distortion and ringing effect by sound feedback at high gain operation those are the major problems of conventional hearing aid. In this paper, we have manufactured the IME system using differential electromagnetic transducer(DET) and verified the performance of the system by carrying out vibration and animal implanting experiment. The DET was manufactured using micro-machining technology and vibration experiment of the transducer was performed to inspect whether the transducer could vibrate in accordance with the applied sound signal or not. And the result of the loaded experiment using temporal bone sampled from cadaver showed that the transducer can drive the middle ear bone and transmit the signal to inner ear After the internal unit of IME system was implanted in a dog. the auditory brainstem response (ABR) test was carried out. The result of the test indicated the Proper behavior of the IME system in the living body From the results of the experiments, it is verified that the manufactured system ewll work well when it is applied to human and a basis of clinical experiment of IME system to real human hearing impaired was be arranged.

THE NONDESTRUCTIVE MEASUREMENT OF THE SOLUBLE SOLID AND ACID CONTENTS OF INTACT PEACH USING VIS/NIR TRANSMITTANCE SPECTRA

  • Hwang, I.G.;Noh, S.H.;Lee, H.Y.;Yang, S.B.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.210-218
    • /
    • 2000
  • Since the SSC(soluble solid contents) and titratable acidity of fruit are highly concerned to the taste, the need for measuring them by non-destructive technology such as NIR(Visual and Near-infrared) spectroscopy is increasing. Specially, in order to grade the quality of each fruit with a sorter at sorting and packing facilities, technologies for online measurement satisfying the tolerance in terms of accuracy and speed should be developed. Many researches have been done to develop devices to measure the internal qualities of fruit such as SSC, titratable acidity, firmness, etc. with the VIS(Visual)/NIR(Near Infrared) reflectance spectra. The distributions of the SSC, titratable acidity, firmness, etc. are different with respect to the position and depth of fruit, and generally the VIS/NIR light can interact with fruit in a few millimeters of pathlength, and it is very difficult to measure the qualities of inner flesh of fruit. Therefore, to measure the average concentrations of each quality factor such as SSC and titratable acidity with the reflectance-type NIR devices, the spectra of fruit at several positions should be measured. Recently, the interest about the transmittance-type VIS/NIR devices is increasing. NIR light can penetrate through the fruit about 1/10-1/1,000,000 %. Therefore, very intensive light source and very sensitive sensor should be adopted to measure the transmitted light spectra of intact fruit. The ultimate purpose of this study was to develop a device to measure the transmitted light spectra of intact fruit such as apple, pear, peach, etc. With the transmittance-type VIS/NIR device, the feasibility of measurement of the SSC and titratable acidity in intact fruit cultivated in Korea was tested. The results are summarized as follows; A simple measurement device which can measure the transmitted light spectra of intact fruit was constructed with sample holder, two 500W-tungsten halogen lamps, a real-time spectrometer having a very sensitive CCD array sensor and optical fiber probe. With the device, it was possible to measure the transmitted light spectra of intact fruit such as apple, pear and peach. Main factors affecting the intensity of transmitted light spectra were the size of sample, the radiation intensity of light source and the integration time of the detector. Sample holder should be designed so that direct light leakage to the probe could be protected. Preprocessing method to the raw spectrum data significantly influenced the performance of the nondestructive measurement of SSC and titratable acidity of intact fruit. Representative results of PLS models in predicting the SSC of peach were SEP of 0.558 Brix% and R2 of 0.819, and those in predicting titratable acidity were SEP of 0.056% and R2 of 0.655.

  • PDF

A study on the trend in the length of hospital stay in Korea (우리나라 병원의 평균재원기간의 추이)

  • Cho, Woo-Hyun;Chun, Ki-Hong;Kang, Im-Ok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.1 s.52
    • /
    • pp.51-65
    • /
    • 1996
  • The purpose of this study was to examine the trends of length of hospital stay (LOS), which is most likely to be a major attribute to hospital performance. From 1984 to 1994, an average LOS of each hospital was analyzed by factors such as medical departments, bed size, occupancy rate, region and ownership. This study was analyzed changing rate of LOS during 11 years. This rate was calculated by simple regression, which was used only with hospital without missing data during 11 years. This study findings are as follows. 1. The results indicated that the average LOS was steadily increased until 1990 but it was slightly decreased after 1990. 2. This trend could be found in all hospital scale and all group of occupancy rate. Specifically this trends of LOS were found in internal medicine, corporate owned hospitals, and hospitals in major city. But LOS of individual owned hospital was continuously increased until 1994. 3. Means of changing rates of LOS were calculated from 1984 to 1994. If we devided it into two parts, before 1990 and after 1990, most changing rates of LOS before 1990 except individual owned hospital were found positive sign. The changing rates after 1990 were negative sign but small hospital(lesser then 200 bed), individual owned hospital, national & public hospital and hospital in small urban have little change of LOS after 1990. Finally from this results we thought that most hospitals in Korea began to be concerned with LOS. Nevertheless LOS of several hospital such as small hospital or individual owned hospital was increased. And this trend may be caused by a few patients, low occupancy rate, or low profit. This trend of LOS is different from that of other countries. Perhaps this phenomenon is resulted from the reimbursement method. Because of fee for service reimbursement system in Korea the hospitals didn't need to shorten LOS in order to save the cost and increase the profit. Therefore reform of hospital cost reimbursement method will be needed to reduce hospital cost in Korea. We thought that the Korean health authority should consider the reimbursement method by unit of bundle of services, for example DRG and prepayment in the United States. This study presents some limitations such as no insight of severity of disease, case-mix measurement of hospital, and other clinical characteristics that can. possibly affect LOS. However, this study reports an important trend in LOS from 1984 to 1994.

  • PDF

Performance of Gated Myocardial Perfusion SPECT to Diagnose Coronary Artery Disease (게이트 심근 관류 SPECT의 관상 동맥 질환 진단 성능)

  • Kang, Won-Jun;Lee, Myoung-Mook;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.50-56
    • /
    • 1997
  • Gated SPECT can evaluate the regional wall motion of the heart. We evaluated the regional wall motion of the perfusion abnormality in conventional perfusion SPECT with gated SPECT. In case of suspicious perfusion abnormalities, we tried to differentiate the artifact from true abnormality in coronary vascular disease using gated SPECT. We thought that artifacts would have normal wall motion, whereas fixed defects with decreased wall motion would probably represent coronary artery disease. A total of 275 patients who were performed coronary angiography and T1-201 rest/Tc-99m MIBI dipyridamole stress gated SPECT within 2 months were enrolled. In coronary angiography, stenosis more than 50% was considered as coronary artery disease. After injection of 111MBq T1-201 rest image was obtained on triple head SPECT system. 370MBg Tc-99m MIBI was used for the stress image. Eight-frame per-cardiac-cycle gated Tc-99m SPECT studies were done. All the images were analyzed visually. Using perfusion SPECT, the overall sensitivity and specificity were 87% and 55% respectively. Regarding artery territory, sensitivity and specificity were 68% and 73% for left anterior descending artery(LAD), 62% and 78% for right coronary artery(RCA), 42% and 90% for left ciramflex artery(LCX). Using gated SPECT, the overall sensitivity and specificity were 87% and 66% respectively. Sensitivity and specificity were 68% and 78% for LAD, 62% and 79% for RCA, 42% and 90% for LCX. Among 21 false positive cases in perfusion SPECT, 5 cases were interpreted as true negative with gated SPECT. We conclude that gated SPECT provides a valuable adjunct to perfusion SPECT in characterizing perfusion abnormalities and to improve specificity.

  • PDF