• 제목/요약/키워드: Internal Fault

검색결과 249건 처리시간 0.027초

A Study on the Improvement of the Domestic Maintenance Capability Development System of Military for Overseas Maintenance Items through the Case Study of Intermittent Failure of an Avionics (항전계통 간헐결함 사례 분석을 통한 군의 해외 정비품 국내정비능력 개발제도 개선방안 고찰)

  • Lee, Hoyong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • 제26권2호
    • /
    • pp.68-75
    • /
    • 2018
  • A flare from an Air Force fighter was abnormally dispensed during the landing. To determine the cause of the abnormal dispensing, fracture analysis, signal analysis and reproduction experiments based on physics of failures were performed. The primary cause of the failure was analyzed to be due to an intermittent fault of an internal circuit card in the AN/ALE-40 chaff/flare dispenser by a broken lid of a capacitor, and the root cause which had derived the primary cause was considered to be an improper handling during the domestic maintenance which were changed from the overseas maintenance due to the DMSMS problem. Therefore, the overall process of the maintenance capability development system was reviewed and alternative ways that considers maintenance error decision aid(MEDA) for system improvement were suggested to prevent further failures.

Case of slope stability in weathered metamorphic rock (풍화된 변성암 사면의 안정대책 사례)

  • Kim, Jae-Hong;Park, Chal-Sook;Jeon, Je-Sung;Hong, Won-Pho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1400-1405
    • /
    • 2008
  • Execute surface of the earth geological survey for stability analysis of stealing cutting sides and investigated wide area nature of soil structure. Inflected DIPS that measure discontinuity's direction that develop to slope and is slope stability a wide use program for Stereographic Projection Method analysis that utilize geometrical correlation of stealing four sides and discontinuity surface. It is principle that angle of internal friction that is basis element of stability estimation applies direct shear test result on joint side, Examination is impossible by case execution, suppose by 30 angles that apply more conservatively in base rock slope sides usually and achieved analysis. When analyze, consider discontinuity's various adult that develop in research slope, after conduct first each discontinuity different assay falling into fault, joint, executed stability estimation which synthesize whole discontinuity data. When ailment element is recognized as analysis result, wished to present stability countermeasure way of most suitable to take into account of execution, stability, economic performance.

  • PDF

Fault Detection of Ceramic Imaging using ART2 Algorithm (ART2 알고리즘을 이용한 세라믹 영상에서의 결함 검출)

  • Kim, Kwang Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제17권11호
    • /
    • pp.2486-2491
    • /
    • 2013
  • There are invisible defects by naked eyes in ceramic material images such as internal stomata, cracks and foreign substances. In this paper we propose a method to detect and extract such defects from ceramic pipe weld zone by applying ART2 learning. In pre-processing, we apply Ends-in Search Stretching to enhance the intensity and then perform fuzzy binarization with triangle type membership function followed by enhanced ART2 that interacts with random input patterns to extract such invisible defects. The experiment verifies that this proposed method is sufficiently effective.

Investigation into Transformer Protective Relay Setting Rule Considering Error Ratio (오차를 고려한 765kV 변압기 보호 계전 정정룰 고찰)

  • Bae, Y.J.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Kim, S.T.;Choi, J.L.;Jeong, C.H.;Yoo, Y.S.;Cho, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.229-231
    • /
    • 2002
  • The digital current differential relaying scheme is widely used for primary protection of 765(kV) power transformer. The current differential relay pickup the internal fault at the threshold which is set at 30% of rating current. Margin of 30% include current transformer error 5%, relay error 5%, on load tap changer error 7% and margin factor 140% obtained from the field experience. In this paper transformer protection relay and relay setting rule of high voltage power system are discussed. And we verify the correctness of relay setting rule with current differential relay using Matlab simulation.

  • PDF

A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC (HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법)

  • Ahn, Jong-Bo;Kim, Kook-Hun;Lee, Jong-Moo;Lee, Ki-Do
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF

Development of Alloy with High Strength and Damping Capacity for High-Performance of Precision Devices by Vibration Control (진동제어에 의한 정밀기기의 고성능화를 위한 고강도 및 고감쇠능 합금개발)

  • Kana, Chang-Yong;Kim, Ik-Su
    • Journal of Ocean Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.46-51
    • /
    • 2008
  • The effect of the addition of Co and N and subzero treatment on tensile strength and damping capacity was investigated in Fe-Cr-Mn alloy. Austenite was transformed into martensite by cold rollins increasing the degree of cold rollins led to an increase in the volume fraction of martensite. The damping capacity linearly increased with increasing volume fraction of ${\varepsilon}$ martensite in cold rolled specimens and subzero treated specimens after cold rolling. The volume fraction of ${\varepsilon}$ martensite, tensile strength and damping capacity was also increased by the addition of Co, while this treatment decreased the elongation. However, the volume fraction of ${\varepsilon}$ martensite, elongation and damping capacity were reduced by the addition of N, although the tensile strength increased. Tensile strength and damping capacity werealso increased by subzero treatment, while elongation decreased.

A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data (ATPDraw5.7p4 모델링 데이터를 이용한 전압억제 과전류계전기 동작특성에 관한 연구)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제61권1호
    • /
    • pp.23-28
    • /
    • 2012
  • The market of domestic Power Plant Generator Protection and Control System (GPCS) is narrow and required the high reliability, and technology. So, it is still operated as turn-key. In recent years, digital relays has evolved into IED can perform the control and monitoring functions without central monitoring based on IEC61850 international standards communications, and attention for advancement of smart grid and ECMS has been increased in South Korea. The increasing attention on multi-function IED, DGPS(digital generator protection system), for internal fault protection of large generator results in starting a national project in South Korea, the IED prototype development for next-generation power units. The voltage restrained overcurrent relay have been used as back-up overcurrent protection for generators. In this paper, voltage restrained overcurrent relay is one of the back-up protective factors in generator protection IED was presented. For evaluation performance of the voltage restrained overcurrent relay, the data of ATPDraw5.7p4 modeling was used.

Experimental Approach and Simulation-Based Design of Eddy Current Sensors for Inspection of Vehicular Bolts (자동차용 볼트의 검사를 위한 시뮬레이션에 기반한 ECT 센서 설계 및 실험적특성)

  • Im, Kwang-Hee;Lee, Seul-Gi;Kim, Hak-Joon;Song, Sung-Jin;Woo, Yong-Deuck;Ra, Seung-Woo;Lee, Hyung-Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제24권3호
    • /
    • pp.294-301
    • /
    • 2015
  • Oil filters for vehicular parts are used under high and low temperatures as the engine is cooled, and defects can be generated with repeated changes in the operating environment and with changes in the shape, such as very high internal losses for the bolts. Visually checking for defects inside a bolt is impossible. Nondestructive evaluation methods such as eddy current testing (ECT) are recommended as a more effective way to examine inside a bolt and detect surface defects in a short amount of time. In this study, the fit bobbin coil eddy current probe was applied to checking the bolts. The bolt parameters were calculated by using a COMSOL analysis program to obtain parameters for professional interior design and fault diagnosis.

Application of GPR Technology for Detecting Bedrock under Conductive Overburden and Geological Survey (전도성 충적지반의 지질 및 하부 기반암 조사를 위한 지하레이다(GPR)의 적용)

  • 윤운상;배성호;김병철;김학수
    • Tunnel and Underground Space
    • /
    • 제5권2호
    • /
    • pp.114-122
    • /
    • 1995
  • The principle and applications of GPR(Ground Penetrating Radear) are familiar to engineering geologists and geophsicists as very attractive technique for continuous high resolution images of the subsurface. However, the main limitation of GPR is obviously related to presence of clayey or silty conductive soils, resulting in complete attenuation of radar signals. This difficulty gives hesitation for the exploration of the deeper targets for example detecting bedrock, particularly in Korean situation that most regions have conductive overburden. In order to prove usefulness of geological survey with GPR in that situation, the technique was tried to investigate depth of bedrock under thick conductive overburden and the other geolocgical informations for the constructionof foundation in the Dongbu apartment site, Kimhae. The reflection patterns on the processed GPR sections are well correlated with the geotechnical units-bedrock, alluvium, landfill unit and their internal layer-boundaries of boring data before GPR survey, except upper contact of bedrock. The isopach maps of the geotechnical units for the 3-D interpretations are made from GPR sections. The maps provided useful geological information that bedrock was distributed as plain and valley with 22~27m depth under alluvium unit (this depth is 5~8 m deeper than drill log) and sedimentary layers subsided and bended along growth fault with NNE strike/15$^{\circ}$SE dip in alluvium unit.

  • PDF

Problems and Inprovement Method of Grounding System in Electrical Facilities (건축전기설비에 적용되는 접지시스템 문제점과 개선방안)

  • Chung, Young-Ki;Kwak, Hee-Ro;Shin, Hyo-Sub;Chung, Chun-Byoung;Nam, Taik-Joo
    • Electric Engineers Magazine
    • /
    • 제228권8호
    • /
    • pp.52-57
    • /
    • 2001
  • Presently the Korean grounding system uses TN system, multi-grounding method with IT independent grounding method. Nevertheless TN system can't exist with TT system in the technological terms. If they coexist, it causes ground-fault circuit not to operate, and brings about different electrical potential rise by customer system. It brings about serious problems for safety. This paper aims for improving method of grounding system based on the technical analysis on instances in foreign countries and Korea. Almost standards and construction manner were apt to be internationalized after WTO/TBT agreement was concluded. The internal grounding systems should meet the international criteria and reliability for safety, and be provided with technologically impeccable standards.

  • PDF