• 제목/요약/키워드: Internal Cavity

Search Result 393, Processing Time 0.031 seconds

Development of 4 Types of Fuel Cell's Blower (연료전지 블로어 4기종 국산화 개발)

  • Tak, Bong-Yeol;Kim, Chan-Gyu;Lee, So-A;Jang, Chun-Man
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.91-91
    • /
    • 2011
  • This paper describes development procedure of the four types of fuel cell's blowers: pressurized fuel blower, selective oxidation air blower, cathode air blower, and burner air blower. Diaphragm blowers having two heads are selected to maintain force balance when the rotating arms are moving by the driving motor. Dimensions of a diaphragm cavity is designed according to the optimal design procedure using numerical simulation and experimental measurement. Experimental apparatus is designed by considering the bower characteristics having low flow rate and high pressure. Test blower is operated by a diaphragm, which has suction and discharge port on the top of the blower. For analyzing the internal flow of the blower, three-dimensional Navier-Stokes analysis is introduced in the present study. Throughout the optimal design of the blowers, blower performance is enhanced by reducing the unbalance motion of the rotating arm and loss region in the diaphragm cavity.

  • PDF

A Case of Chronic Sinusitis Patient Improved by Yangdokbackho-tang (양독백호탕(陽毒白虎湯)으로 치료한 만성 부비동염 치험 1례)

  • Lee, Hyeon-Min;Park, Seong-Ha
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.283-292
    • /
    • 2007
  • 1. Objectives This study evaluates the effect of oriental medical treatment on a chronic sinusitis patient. 2. Methods The patient was teated with acupuncture, nasal cavity irrigation, and Yangdokbackho-tang(陽毒白虎湯). Previous western medical methods were excluded in order to provide therapeutic methods different from pre-existing ones because we needed different, long-term treatment plan from previous treatment. We applied acupuncture 15 times during treatment period and instructed the patient to carry out nasal cavity irrigation at home. 3. Results & Conclusions Combined application of oriental treatment including administration of Yangdokbackho-tang and nasal irrigation showed remarkable clinical effects on symptom, physical examination and radiological finding.

  • PDF

A Study of Output Characteristics for the Generation Panel using Unimorph Piezoelectric Element (유니몰프 압전소자를 이용한 발전 판넬의 출력특성에 관한 연구)

  • Kim, Yong-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.3
    • /
    • pp.250-259
    • /
    • 2010
  • The ability for energy harvesting via the piezoelectric effect was studied for a unimorph element such as piezo buzzer. A simple equivalent circuit was proposed to predict the energy generated based on the internal stress. Unimorphs with a metal-cavity were used as a driving device of the generation panel. Both the AC open voltage and DC output voltage as a function of pressure period and number of element were measured. For the unimorph generation circuit, DC output voltage varies with pressure period, reaching a maximum value at $470{\mu}F$. The maximum output voltage a according to load resistance was measured at $1M{\Omega}$. Data analysis of the DC output voltage and time constant indicated that number of piezoelectric element of optimum was 60~80. It was found that piezoelectric unimorph has the possibility to be used as the driving element of the electric generation.

Resonance Frequency of the Natural Convection in the Closure Cavity for the Variable Aspect Ratio (종횡비가 변하는 공동 내 자연대류의 공진주파수)

  • Chun, Kun-Ho;Joo, Kwang-Sup;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.609-614
    • /
    • 2000
  • This numerical study investigate resonance frequency of natural convection for steady state, periodic flow and chaotic flow in two-dimensional direct numerical simulations, differentially heated, vertical cavities having aspect ratios near unity. The enclosure cavity has isothermal and time dependent temperature side walls and adiabatic top/bottom walls. The aspect ratio is 1/3, 1/2, 1, 2, and 3 for the varying Rayleigh number. Resonance frequency for AR=1 has decrease as the aspect ratio and the Rayleigh number are increasing.

  • PDF

Thermal-hydraulic simulation and evaluation of a natural circulation thermosyphon loop for a reactor cavity cooling system of a high-temperature reactor

  • Swart, R.;Dobson, R.T.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.271-278
    • /
    • 2020
  • The investigation into a full-scale 27 m high, by 6 m wide, thermosyphon loop. The simulation model is based on a one-dimensional axially-symmetrical control volume approach, where the loop is divided into a series of discreet control volumes. The three conservation equations, namely, mass, momentum and energy, were applied to these control volumes and solved with an explicit numerical method. The flow is assumed to be quasi-static, implying that the mass-flow rate changes over time. However, at any instant in time the mass-flow rate is constant around the loop. The boussinesq approximation was invoked, and a reasonable correlation between the experimental and theoretical results was obtained. Experimental results are presented and the flow regimes of the working fluid inside the loop identified. The results indicate that a series of such thermosyphon loops can be used as a cavity cooling system and that the one-dimensional theoretical model can predict the internal temperature and mass-flow rate of the thermosyphon loop.

CONCEPT DESIGN THEORY OF SHOCK ABSORBING MUFFLERS FOR AIR-BORNE NOISE (유체기인 방사소음 저감용 소음기 개념설계 이론)

  • Kim, Sang-Myeong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.627-632
    • /
    • 2002
  • The paper considers acoustic analysis of the shock absorbing muffler within a rotary compressor. The internal space of the compressor is modelled as a combination of cavities and pipes. A simple one-dimensional impedance approach is used fur the acoustic analysis in the low frequency range, with ignoring the effects of gas flow and temperature gradients that are closely related to power efficiency of the compressor. Using the similarity between the vibration isolator and the shock absorbing muffler, the source strength transmissibility is newly proposed as a performance measure of the muffler and its validity is supported by power analysis. Some Important muffler design rules obtained are; (1) a muffler cavity and its opening throat should be used as a pair, (2) a long thin throat is desirable for high frequency noise isolation, (3) a large muffler cavity should be used with care since it shortens the working frequency range of the muffler. The rules were applied to redesign a compressor muffler currently in use, and a significant improvement was achieved by simply attaching a throat to the outlet holes of the muffler.

  • PDF

Predicting Noise inside a Trimmed Cavity Due to Exterior Aero-Acoustic Excitation (외부 유동 소음원에 의한 흡차음재 공간내에서의 소음 예측)

  • Jeong, ChanHee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.569-569
    • /
    • 2014
  • The interior vehicle noise due to the exterior aerodynamic field is an important topic in the acoustic design of a car. The air flow detached from the A-pillar and impacting the side windows are of particular interest as they are located close to the driver / passenger and provides a lower insulation index than the trimmed car body parts. This paper presents a numerical analysis method for a simplified vehicle model. The internal air cavity including trim component are included in the simulation. The car body includes the windshield and two side windows. The body is made of aluminum and trimmed with porous layers. The methodology proposed in this paper relies on two steps: the first step involves the computation of the exterior flow and turbulence induced non-linear acoustic field using CFD Code. The second step consists in the computation of the vibro-acoustic transmission through the window using the finite element vibro-acoustic solver Actran.

  • PDF

Acoustic Mode Analysis to Identify Cavity Noise of Scroll Compressor (스크롤 압축기의 공동 소음 규명을 위한 음향모드 분석)

  • Kim, Seung-Yup;Lee, Dong-Soo;Suh, Jeong-Hwan;Heo, Dae-Nyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.83-88
    • /
    • 2004
  • Acoustic modes of internal region of 4-hp scroll compressor are identified by measuring transfer functions between a reference and 84 measuring points. The corresponding acoustic mode-shapes and natural frequencies were calculated by analysis software SYSNOISE. There exist two clearly distinguishable dipole modes of vertical and horizontal direction and a single quadrupole mode in the frequency region of interest. It shows that the natural frequencies of the identified modes are linearly sensitive to suction pressure (Ps) but relatively in sensitive to discharge pressure (Pd) in operating condition.

  • PDF

A Case of Pneumonia and Parapneumonic Effusion Caused by Streptococcus parasanguinis (Streptococcus parasanguinis에 의한 폐렴과 부폐렴성 흉수 1예)

  • Park, Myoung-Rin;Park, Dong-Il;Yoo, Su-Jin;Jung, Sun-Young;Eun, Hyuk-Soo;Kim, Min-Jung;Park, Ji-Won;Park, Hee-Sun;Jung, Sung-Soo;Kim, Ju-Ock;Kim, Sun-Young;Lee, Jeong-Eun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.5
    • /
    • pp.359-362
    • /
    • 2011
  • Streptococcus parasanguinis is a Viridans group bacteria that is most often discovered in the oral cavity and causes dental plaque and endocarditis in a rat model. It has low virulence but an unknown relationship to human respiratory infections. We report on a 61-year-old woman who developed hemoptysis followed by pleuritic chest pain after conscious sedation during a gastroscopic polypectomy and was diagnosed with pneumonia and parapneumonic effusion from Streptococcus parasanguinis isolated in pleural fluid. Microaspiration during the procedure was presumed to play a role in the pathogenesis.

Chronic Progressive Pneumonic Consolidation with Cavity (공동을 동반한 만성 진행성 폐렴양 병변)

  • Kwon, Seon-Og;Kim, Hyung-Jung;Ahn, Chul-Min;Kim, Sung-Kyu;Lee, Won-Young;Kim, Sang-Jin;Lee, Ki-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.38 no.4
    • /
    • pp.401-405
    • /
    • 1991
  • Bronchioloalveolar cell carcinoma accounts for less than 6% of all primary lung cancer but has distinct clinical and radiological features and unusual pathologic appearance. The characteristic features are its peripheral location and tendency of rapid progression to diffuse type via aeroginous and lymphatic route without surgical intervention. Among them, mucin secretory type bronchioloalveolar cell carcinoma is the rarest and most distinctive. We experienced a case of mucin secretory type bronchioloalveolar cell carcinoma in a 47 year old female with roentgenographic findings of chronic progressive pulmonary consolidation with muliple cavities.

  • PDF