• Title/Summary/Keyword: Interior fire test

Search Result 65, Processing Time 0.025 seconds

A Study on the Safety Regulation Revision for Urban Transit Vehicles (도시철도차량의 안전기준 강화에 관한 연구)

  • Lee Woo-Dong;Shin Jeong-Ryol;Kim Gil-Dong;Han Suk-Youn;Park Kee-Jun;Hong Jai-Sung;Ahn Tai-Ki;Lee Ho-Yong;Kim Jong-Wook
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.322-326
    • /
    • 2003
  • Dae-gu subway accident raise whole points in connection with safety facilities and operating of national urban transit system like rolling stocks, facilities, management of human. Rolling stock is made every effort for improvement of performance, guarantee of comfortableness, insurance of economical efficiency. But Security like safety of fire is not thoroughgoing enough. Especially, interior material has used although it is not prove its degree of safety. it is a main cause of Dae-gu subway accident. Safety regulation of urban transit vehicle that legislate for security in March 2000 does not applied manufacturing vehicles before in 2000. It has be prescribed in the regulations that incombustibles must be used. But detailed test standard related with incombustibles is not prescribe. Thus that regulation be required reinforcement of detailed test standard. Main cause of Dae-Gu subway accident is a fire in vehicle. However, many defects are found in infrastructure and operating vehicle of urban transit, such as inexperienced disposal of driver and CCC in early stage of the fire accident, unskilled opening and closing doors, insufficient escape facilities and safety facilities of a station house and tunnel, and incomplete communication system between vehicle and CTC, extraordinary step. Thus the aims of this study are prevention of urban transit accident, improvement plan of safety driving, and proposal of quick action plan through analysis of total faculty of vehicle.

  • PDF

Comparative study on the Limited Oxygen Index of the gangway materials of the railroad vehicles (철도차량용 통로 연결막의 재질별 산소지수 비교연구)

  • Park, Ji-Young;Jung, Woo-Sung;Kwon, Sung-Tae;Lee, Duck-Hee;Lee, Jong-Min
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1511-1516
    • /
    • 2007
  • According to ISO 4589-2:2001, we studied on the fire characteristics of some gangway materials used as the interior materials of the railroad vehicles. Currently materials of the gangway used in the railroad vehicles tend to alternate PVC coated fabric mostly used in former days with synthetic rubber or silicone. Accordingly, we compared Limited Oxygen Index on them in this study. And we found that the test results of the synthetic rubber or silicone gangway are better than those of the PVC coated fabric gangway largely.

  • PDF

A Study on Combustion Characteristics of Finishing Materials in Interior Decoration (실내장식물 인테리어마감재의 연소특성에 관한 연구)

  • Cho, Kwang-Hyun;Lee, Bong-Woo;Yun, Mung-Oh
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.10-18
    • /
    • 2019
  • The Interior finishing materials tried to evaluate the combustion characteristics and the dangerous characteristic of Floor finish and Wall finish. We often use, conducting the experiment ISO 5660-1, Cone Calorimeter method, and ISO-TR-9122 FT-IR. According to the result of Cone calorimeter experiment, the tile carpet FF3 of Floor material had the highest THR $74.6mj/m^2$ because of the highest risk, and the PHRR of FF1 was $726kW/m^2$, which was easy to bum. As a result FT-IR test, The CO, $CO_2$ ratio was 8,146 PPM for roll carpet FF1 than tile carpet FF2, FF3 5,996, 5,171 PPM, which was a carpet with a high toxicity risk. In the case of wall finishes, The MDF plate(WF3) was THR $86.7mj/m^2$ with a high risk, PHRR $384kW/m^2$ was easy to ignite and toxicity index was 5.5. The CO, $CO_2$ ratio was 1,340~8,596 PPM, But the WF4 was the most toxic with 8,596 PPM.

A Study on P-M Interaction Diagram of Fire-Damaged High Strength Concrete Column (화재 피해를 입은 고강도 RC 기둥의 P-M 상관곡선에 관한 연구)

  • Kim, Hyun-Jung;Choi, Eun-Gyu;Shin, Yeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.257-260
    • /
    • 2008
  • This study will make P-M interaction diagram of residual capacity at fire-damaged High strength concrete column with polypropylene fiber. Evaluating capacity of column decreasing spalling with P-M interaction diagram is important. because high strength concrete column with polypropylene fiber isn't section area loss. P-M interaction diagram that is made to analyze according to a various parameters is useful index for design and evaluating capacity of columns. In this study, spalling, temperature distribution of interior column, residual strength and movement of column in eccentric loading are studied with expose time of high temperature. For study fire test that is similar real act, and after cooling in normal condition residual strength of specimen is estimated. And this study use DIANA(Displacement Analyzer) for analyzing nonlinear analysis. with experiment temperature and strength data.

  • PDF

Plans to Improve Safety Experience Education through the Experimental Analysis of Evacuation Equipment (피난기구 사용시간 실험분석을 통한 안전체험교육 개선방안)

  • Lee, Jeong Il;Lee, Sung Eun
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.35-42
    • /
    • 2019
  • The aim of this study is to investigate the direction of improvement of safety experience education through the analysis of the evacuation time experiment. For the study, test subjects were divided into groups of similar body size and weight. The test subjects were directly experienced four evacuation devices, and the experience time was measured. As a result of the analysis of the total time from the installation of the evacuation device to the escape, the time was measured in the order of Descending Life Line-Tilt-Down Rescue Line-Vertical Escape Chute-air safety mat. In the case of evaluating the evacuation time using evacuation mechanisms, the evacuation time was measured in the order of air safety mat-Tilt-Tilt-Down Rescue Line-Descending Life Line-Vertical Escape Chute. In the first and second experiments of the Descending Life Line, time differences were observed. The escape time using the Descending Life Line was reduced in the second experiment than in the first experiment. As shown in this result, education through experience has shown that behavioral confidence and time can be managed. The conclusion of this study is that the goal of safety education is to minimize human life and property damage. Therefore, in order to bring this effect to more people, it is necessary to make efforts to keep self-safe through experiential education.

Fireproof Performance of Mortar using Gypsum in Simplified Heating Test (간이 내화시험에 의한 석고계 모르타르의 내화성능)

  • Kang, Suk-Pyo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.181-188
    • /
    • 2011
  • Spalling must be considered when designing high-strength concrete to cope with fire. This study investigates the temperature rise of steel bar in high-strength concrete coated with fireproof mortar using gypsum exposed to fire. It was found that fireproof mortar using gypsum is more effective in constraining the temperature rise of steel bar in the high strength concrete than fireproof mortar using cement, and that the thinner the cover depth of the fireproof mortar, the more significant the influence of the gypsum. In addition, while there was no difference between ${\alpha}$-hemihydrate mortar and ${\beta}$-hemihydrate mortar on the temperature rise of steel bar, the compressive strength of ${\alpha}$-hemihydrate mortar is higher than that of ${\beta}$-hemihydrate mortar.

A Study on the Toxic Gases and Smoke Hazard of PASCON Trough (파스콘 트로프의 연기유독성에 관한 연구)

  • Lee, Chang-Woo;Hyun, Seong-Ho;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research is to estimate the effect of smoke and combustion gases on humane body indirectly through measuring the toxicity of those. For this purpose, the toxic index of smoke and combustion gases was investigated by smoke hazard test and analysis of smoke which were conducted by KS F 2271 and NES 713 method respectively. It i s proved by KS F 2271 method that PASCON trough is suitable to the testing standard of interior material and construction of building. In addition, it is identified by NES 713 method that combustion gases occurring in PASCON product were only carbon dioxide and carbon monoxide, and the smoke index of those was 0.944. This value means that the hazard effect of smoke gases on humane ! body can possibly happens when exposed to the smoke gases for more than 30 min. In aspect of the domestic situation that have not regulated the hazard estimation and the emissions of smoke when the flame retarding ability of the products have been requested, the toxic indexes of PASCON products are comparatively low.

A Study on K2 Rifle Recoil Measurement and Analysis for Virtual Reality Marksmanship (가상현실 사격훈련을 위한 탄종별 K2 소화기의 주퇴산출 및 분석 연구)

  • Kim, Jong-Hwan;Jin, Youngho;Kwak, Yunki
    • Journal of Korean Society for Quality Management
    • /
    • v.48 no.1
    • /
    • pp.13-27
    • /
    • 2020
  • Purpose: The purpose of this study is to present a recoil measurement and analysis of K2 rifle for the development of a virtual reality marksmanship training in the Republic of Korea Army. Methods: For the recoil measurement, a test-bed is built by a barrel that has exact dimensions of K2 rifle and three piezoelectric pressure sensors mounted on the barrel. Data of over 200 rounds of 5.56mm M193 and K100 bullets are collected and analyzed from live fire experiments. For the recoil analysis, both the free recoil method and the gas exhaust aftereffect method are used to calculate a recoil velocity, momentum and kinetic energy of K2 rifle by applying the law of conservation of momentum. In addition, a new method is proposed that uses the third law of motion and the chamber pressure model for the recoil measurement Results: The results show how different between the previous and proposed methods with respect to M193 and K100 bullets of K2 rifle. In M193, the free recoil method demonstrates 1.113, 4.197, and 2.335, the gas exhaust aftereffect method computes 1.698, 6.407, and 5.441, and the proposed method calculates 0.990, 3.734, and 1.848 in recoil velocity, momentum and kinetic energy, respectively. In K100, the free recoil method demonstrates 1.190, 4.487, and 2.669, the gas exhaust aftereffect method computes 1.776, 6.699, and 5.949, and the proposed method calculates 1.060, 3.998, and 2.119 in recoil velocity, momentum and kinetic energy, respectively. Conclusion: This study implements live fire experiments to provide recoil velocity, momentum, and kinetic energy of K2 rifle using both M193 and K100 bullets. For the development of the army virtual reality marksmanship, the results in this paper would be useful to design and produce a gun and/or a rifle of virtual reality.

Studies on the Press Drying and the Chemical Absorption of the Plywood Treated with Diammonium Phosphate (제2인산(第2燐酸)암모늄 처리합판(處理合板)의 약제흡수(藥劑吸收) 및 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.39-45
    • /
    • 1995
  • The plywoods commonly used as decorative interior materials for the construction are inflammable and so it is a causative factor for making fire accidents, resulting in the destruction of human life and personal properties. Indeed, it is, therefore, required to produce fire-retardant plywoods. In this study, a special grade of defect-free, Kapur plywood was used. Specimens were cut into 3- by 20cm dimensions from 120- by 240- by 0.33-cm panels(thin panel) or 120- by 240- by 0.5-cm panels(thick panel). Some specimens were treated with diammonium phosphate(DAP), but some were not treated with diammonium phosphate to use as control panels. Chemical absorption, drying curves, drying rates and dynamic Young's modulus were investigated. The results were summaries as follows; 1. The specimens were soaked into 19% diammonium phosphate solution by a full cell pressure process and the diammonium phosphate retained in the thin and thick plywoods was 1.409kg/$(30cm)^3$, 1.487kg/$(30cm)^3$, respectively. 2. Diammonium phosphate-treated plywoods were redried with press-drying process at one of either condition dried on the platen($115^{\circ}C$) for a period of time or dried on the platen($50^{\circ}C$) for 3 hrs plus in a dry-oven($30^{\circ}C$) for 24 hrs. or dried on the platen($60^{\circ}C$) for 2 hrs plus in a dry-oven($30^{\circ}C$) for 24 hrs. The drying rate of treated thin specimens dried at $60^{\circ}C$ plus $30^{\circ}C$ and $115^{\circ}C$ only was found to be 0.04 %/min. and 8.53 %/min. Similarly, the drying rate of treated thick specimens were 0.03 %/min. and 6.77 %/min. respectively. 3. It was evident that highly-significantly different drying rate of treated plywoods was observed between plywood thicknesses and platen temperatures and the rate was increased by elevating the platen temperature up to $115^{\circ}C$. Based on the two-way variance analysis, highly significant drying rate was observed from the interaction between plywood thicknesses and platen temperatures. 4. After redrying, the specimens were weighed and reconditioned to a constant weight in a facility maintained temperature ($20^{\circ}C$) and relative humidity(65%) prior to test dynamic Young's modulus. The test revealed that the thin specimens dried at the platen temperature of $50^{\circ}C$, $60^{\circ}C$, $115^{\circ}C$ and untreated specimens showed 1.070E+09 dyne/$cm^2$, 1.156E+09 dyne/$cm^2$, 1.243E+09 dyne/$cm^2$, and 1.052E+09 dyne/$cm^2$, respectively. Likewise, the thick specimens revealed 5.647E+09 dyne/$cm^2$ 5.670E+09 dyne/$cm^2$, 6.395E+09 dyne/$cm^2$ and 5.415E+09 dyne/$cm^2$, respectively. 5. It was evident that significantly different dynamic Young's modulus was observed between the plywood thickness and the platen temperature, but not in the two-way interaction between the plywood thickness${\times}$the platen temperature.

  • PDF

Failure characteristics of columns intersected by slabs with different compressive strengths

  • Choi, Seung-Ho;Hwang, Jin-Ha;Han, Sun-Jin;Kang, Hyun;Lee, Jae-Yeon;Kim, Kang Su
    • Structural Engineering and Mechanics
    • /
    • v.74 no.3
    • /
    • pp.435-443
    • /
    • 2020
  • The objective of this study was to determine the effective compressive strength of a column-slab connection with different compressive strengths between the column and slab concrete. A total of eight column specimens were fabricated, among which four specimens were restrained by slabs while the others did not have any slab, and the test results were compared with current design codes. According to ACI 318, the compressive strength of a column can be used as the effective compressive strength of the column-slab connection in design when the strength ratio of column concrete to slab concrete is less than 1.4. Even in this case, however, this study showed that the effective compressive strength decreased. The specimen with its slab-column connection zone reinforced by steel fibers showed an increased effective compressive strength compared to that of the specimen without the reinforcement, and the interior column specimens restrained with slabs reached the compressive strength of the column.