This study will make P-M interaction diagram of residual capacity at fire-damaged High strength concrete column with polypropylene fiber. Evaluating capacity of column decreasing spalling with P-M interaction diagram is important. because high strength concrete column with polypropylene fiber isn't section area loss. P-M interaction diagram that is made to analyze according to a various parameters is useful index for design and evaluating capacity of columns. In this study, spalling, temperature distribution of interior column, residual strength and movement of column in eccentric loading are studied with expose time of high temperature. For study fire test that is similar real act, and after cooling in normal condition residual strength of specimen is estimated. And this study use DIANA(Displacement Analyzer) for analyzing nonlinear analysis. with experiment temperature and strength data.

최근 초고층 건물 건설의 증가로 인해 많이 사용되고 있는 고강도 콘크리트가 화재 시 폭렬 현상으로 인해 내화성 문제가 대두되고 있다. 이에 본 연구는 화재 피해를 입은 폴리프로필렌 섬유(PP섬유) 혼입 고강도 RC 기둥의 비재하 가열 실험을 거친 시험체의 냉각 후 재하 실험을 통해 부재의 성능을 평가하였다. 화해 후 폭렬이 저감된 기둥의 성능 평가는 단면 손실이 없어 외관상 평가가 힘들기 때문에 잔존 내력을 추정하고 설계 단계에서 화해에 의한 성능 저하를 고려할 수 있는 기반을 만드는 것이 중요하다. 이에 범용 유한요소 해석프로그램인 DIANA(Displacement Analyzer)를 사용하여 부재를 해석하였고, 실제와 거동과 유사한 해석을 위해 온도 곡선은 재하 가열 실험의 온도 분표를 이용하여 단면 모델링에 적용하였다. 화재 노출 시간, 콘크리트 압축강도, 단면 치수를 변수로 적용하여 해석으로 도출된 화재 피해를 입은 고강도 RC 기둥의 P-M 상관곡선을 통해 잔존 성능을 평가하여 설계에 이용하도록 제시하였다.

Keywords