• 제목/요약/키워드: Interconnected Distribution System

검색결과 125건 처리시간 0.025초

티타늄합금에서 HIP에 의해 형성된 실리사이드의 특성 (Characteristics of Silicides in Titanium Alloys Processed by HIP)

  • 정희원;김승언;현용택;이용태
    • 연구논문집
    • /
    • 통권31호
    • /
    • pp.113-125
    • /
    • 2001
  • Silicon addition in titanium alloys generally results in solid solution hardening by silicon itself and precipitation hardening by titanium silicides. The morphology and distribution of the titanium silicides depend upon the alloy chemistry or the heat treatment condition, and play an important role in improving the mechanical properties of the alloys. In this study, the morphology and crystallographic characteristics of the titanium silicides in the Ti-Fe-Si alloy system were studied. Three types of silicides were found in the alloys; (1) interconnected chain-like silicides at grain boundary, (2) coarse silicides over im, (3) fine silicides smaller than 0.2m. Ti3Si was dominant in cast + HIP condition while Ti5Si3 was dominant in as-cast state. It is recognized that $Ti_5Si_3$$\rightarrow$$Ti_3Si$ transition occurred by the peritectoid reaction and it may be promoted by the pressure during HIP. However, in the case of the fine silicides, $Ti_3Si$ and $Ti_5Si_3$ were found simultaneously even after HIP. Such a fine silicide was found to have a crystallographic orientation relationship with matrix.

  • PDF

Development and Application of a Sensemaking Approach to Community-based Disaster Risk Governance

  • Choi, Choongik;Tatano, Hirokazu;Choi, Junho
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제6권1호
    • /
    • pp.289-301
    • /
    • 2019
  • This paper explores community-based flood disaster risk governance by applying a sensemaking approach. The conceptual sensemaking framework consists of individual experience, dialogue, and socialization components, which together comprise an interconnected system. This study presents a method for applying this framework by using a concerns table and a SWOT analysis to examine the concerns of residents living in a flood plain. A series of community-based workshops on flood risk reduction was conducted with residents of the flood-prone Muraida community in Shiga Prefecture, Japan. During the workshops, residents' concerns regarding flood risk surfaced. This study used an idiographic approach to examine the proceedings of the workshops. SWOT issue analysis was used to examine the strengths and weaknesses in the Muraida community's internal capacities, and examine the opportunities and threats in the external capacities (e.g., local government). Additionally, a SWOT strategy analysis was conducted to identify strategies for knowledge sharing and development of cooperative countermeasures that can be undertaken between the Muraida community and the local government. The results show that the concerns table can not only summarize the main concerns of all workshops, but also provide an understanding of alternative flood risk countermeasures that can be carried out.

지역필터를 이용한 수변전실 접지저항의 새로운 측정방법 (A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations)

  • 이복희;엄주홍;이승칠;김성원;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

The Spatial Performance of Multi-Level Shopping Clusters A Case Study of Nanshan Commercial Cultural District

  • Haofeng, Wang;Yupeng, Zhang;Xiaojun, Rao
    • 국제초고층학회논문집
    • /
    • 제6권2호
    • /
    • pp.149-163
    • /
    • 2017
  • With the intensification of urban development in Chinese cities, mixed land use in urban centers extends vertically into 3-D and expands its scale from a single building to commercial clusters. The multi-level pedestrian system in city centers also changed its role from one of traffic isolation to spatial integration, where transit nodes, street sidewalks, squares, building entrances, atriums, and corridors are interconnected, both horizontally and vertically, into a whole spatial system, within which pedestrian flows are guided and shopping facilities are arranged. This paper uses spatial configuration analysis of space syntax to examine the impacts of spatial patterns on movement distribution and the business performance of tenant mix in the multi-level commercial system of the Nanshan Commercial Cultural District in Shenzhen, China. The key objective is to better understand the interactions between the socio-economic variables and spatial design parameters of a shopping complex. The research findings point to the importance of multiplicity between syntactic variables and other spatial variables in influencing the pedestrian flows, business performance and tenant mix in highly complex commercial systems. Particularly noteworthy is the relationship between spatial accessibility measures and the location of escalators, and the ways in which individual commercial buildings are embedded into the overall spatial system. The study suggests that this may lead to the preliminary identification of the spatial qualities of effective vertical extensions of mixed land use in a high-density urban settings.

정보통신 융합기기 연계를 고려한 데이터 중심의 정보시스템 모델의 설계 및 분석 (Design and Analysis of Data-oriented Information System for Interconnected IT Convergence Devices)

  • 오창익;정종필
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2406-2414
    • /
    • 2013
  • 데이터 중심 정보시스템 구축 모델은 그간 정보화 사업 추진이 HW, SW기능 중심으로 이루어지던 것을, 데이터 구조 및 데이터 수집 배포 채널에 대한 체계적인 분석과 설계, 데이터표준 적용, 정보통신 융합기기의 데이터 설정의 유연성 확보 등의 고려하여 개선한 모델이다. 이 모델의 주요 특성인 정보통신 융합기기에 데이터 유연성이 보장되는 개선 효과에 대해 센서와 반응기로 구분하여 이들 기기에 새로운 정보시스템이 추가적으로 연계되는 상황을 가정하여 시스템 개선 복잡도와 네트워크 환경에 대한 지수를 산정하여 기존의 일반적인 구축 방식과 비교하였다. 본 모델을 확산함으로써, 일반 업무용 정보시스템 외에 나날이 늘어나는 정보기술 융 복합 기기들이 처리하는 데이터에 대해서도 품질과 상호운용성을 통제하게 되어, 정보화 거버넌스의 영역 확대를 통해 종합적인 정보화 기획 및 성과 관리 등이 가능하게 되는 개선 효과가 있다.

Vacuum Carburizing System for Powdered Metal Parts & Components

  • Kowakewski, Janusz;Kucharski, Karol
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1018-1021
    • /
    • 2006
  • Powdered metal parts and components may be carburized successfully in a vacuum furnace by combining carburizing technology $VacCarb^{TM}$ with a hi-tech control system. This approach is different from traditional carburizing methods, because vacuum carburizing is a non-equilibrium process. It is not possible to set the carbon potential as in a traditional carburizing atmosphere and control its composition in order to obtain a desired carburized case. This paper presents test results that demonstrate that vacuum carburizing system $VacCarb^{TM}$ carburized P.M. materials faster than traditional steel with acceptable results. In the experiments conducted, PM samples with the lowest density and open porosity showed a dramatic increase in the surface carbon content up to 2.5%C and a 3 times deeper case. Currently the boost-diffusion technique is applied to control the surface carbon content and distribution in the case. In the first boost step, the flow of the carburizing gas has to be sufficient to saturate the austenite, while avoiding soot deposition and formation of massive carbides. To accomplish this goal, the proper gas flow rate has to be calculated. In the case of P.M. parts, more carbon can be absorbed by the part's surface because of the additional internal surface area created by pores present in the carburized case. This amount will depend on the density of the part, the densification grade of the surface layer and the stage of the surface. "as machined" or "as sintered". It is believed that enhanced gas diffusion after initial evacuation of the P.M. parts leads to faster carburization from within the pores, especially when pores are open . surface "as sintered" and interconnected . low density. A serious problem with vacuum carburizing is delivery of the carbon in a uniform manner to the work pieces. This led to the development of the different methods of carburizing gas circulation such as the pulse/pump method or the pulse/pause technique applied in SECO/WARWICK's $VacCarb^{TM}$ Technology. In both cases, each pressure change may deliver fresh carburizing atmosphere into the pores and leads to faster carburization from within the pores. Since today's control of vacuum carburizing is based largely on empirical results, presented experiments may lead to better understanding and improved control of the process.

  • PDF

분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘 (An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations)

  • 신동열;김동명;차한주
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.

태양광전원 연계용변압기의 결상사고 검출 알고리즘에 관한 연구 (A Study on Detection Algorithm of Open Phase Fault in Grid-Connected Transformer for PV System)

  • 강갑석;태동현;이후동;노대석
    • 한국산학기술학회논문지
    • /
    • 제22권5호
    • /
    • pp.22-33
    • /
    • 2021
  • 태양광전원이 설치된 배전선로의 단선 등으로 결상사고가 발생하는 경우, 연계용변압기의 철심형태 및 결선 방법에 따라 여러 가지 문제점이 발생할 가능성이 있다. 즉, 단선사고 발생 시 태양광전원 인버터의 단독운전 방지기능에 따라 결상을 감지하여 발전을 정지해야 하지만, 결상을 인지하지 못하고 계속 발전하는 사례가 보고되고 있으며, 연계용 변압기의 역조류 현상으로 인해 결상된 상으로 전원을 공급하여 계통에 악영향을 주는 문제점이 발생하고 있다. 하지만, 기존의 결상사고 보호계전기(Open Phase Relay, 47)는 태양광전원 연계용변압기의 결선방식과 철심형태에 따라 결상된 상에 전압이 유지될 수 있어서, 결상사고 검출이 어려워, 새로운 결상사고 검출 알고리즘이 요구되고 있다. 따라서, 본 논문에서는 전류비교방식의 개념을 이용하여, 연계용변압기 1, 2차측의 전류와 위상을 비교하여 결상사고를 검출하는 새로운 개념의 알고리즘을 제안한다. 또한, 전력계통 상용해석 프로그램인 PSCAD/EMTDC를 이용하여 수배전반, 저압배전선로, 부하, 연계용변압기, 태양광전원으로 구성된 배전계통과 결상사고 검출 보호장치의 모델링을 수행하고, 이를 바탕으로 결상사고 검출 보호장치를 구현한다. 상기의 모델링과 결상사고 검출 알고리즘을 바탕으로 태양광전원 연계용 변압기의 결선방식과 철심구조에 따라 결상사고 검출 보호장치의 특성을 분석한 결과, 결상 시 연계용변압기의 동작 기울기와 1차측 전류 불평형률이 보호장치의 정정 값(30[%])을 초과함에 따라 결상사고가 정확하게 검출되어, 제안한 알고리즘이 결상사고 보호방식에 유용함을 알 수 있었다.

공급사슬 관리 구축전략에 관한 연구: LG전자 사례 중심으로 (A study of SCM strategic plan: Focusing on the case of LG electronics)

  • 이기원;이상윤
    • 유통과학연구
    • /
    • 제9권3호
    • /
    • pp.83-94
    • /
    • 2011
  • 국내에서는 일부 대기업을 제외하고는 공급사슬 관리(SCM) 체제 구축에 매우 소극적이며, 중소기업들은 SCM관리의 개념조차 인식하고 있는 경우가 대 다수이다. 이는 공급망 비효율적 관리로 인한 국내 제조업체, 협력업체, 유통업체 및 물류업체들 재고관리 비용, 수요관리 비용 등 비 효율화를 초래하고 있으며, 나아가 국내 기업의 경쟁력 저하에도 큰 영향력을 미치고 있다. 그 이유는 공급사슬 관리(SCM) 태생적인 특징인 공급사슬 관리(SCM) 전체에 대한 정보 공유 및 프로세스 혁신과, 공급사슬 관리(SCM)가 갖는 광범위함 때문이라고도 할 수 가 있다. 이 논문은 성공적인 공급사슬 관리(SCM) 추진을 위한 공급사슬 관리(SCM) 관련 이론적 논의와 구축전략과 도입 및 성공사례를 연구 및 분석을 통하여 현상황에 대한 고찰과 개선방안에 대해서 제안해보고자 한다. 성공적인 공급사슬 관리(SCM) 추진을 위한 방안을 논의하기 위해서는 먼저 공급사슬 관리(SCM)에 대한 이론적 배경에 대한 고찰이 필요하다. 따라서 II장에서는 공급사슬 관리(SCM)에 대한 기본적인 개념과 필요성에 대해서 기술하고, III장에서는 현재 추진되고 있는 공급사슬 관리(SCM)에 대한 문제점에 대해서 기술할 것이다. 마지막으로IV, V장에서는 공급사슬 관리(SCM) 구축전략과 LG전자사례 및 결론을 기술할 것이다.

  • PDF

배양된 사람치은각화상피세포의 미세구조 (CULTURED HUMAN ORAL KERATINOCYTES; ULTRASTRUCTURAL STUDY)

  • 권용대;이백수;주성숙
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권3호
    • /
    • pp.231-239
    • /
    • 1999
  • In oral and maxillofacial surgery, there are many cases requiring the graft of epidermal tissues such as maxillectomy, and vestibuloplasty. There have been so many challenges for the culture of the epidermal tissue. Observing the ultrastructure of the cultured human oral kertinocytes, we could compare this findings with that of in vivo ones. With that, we could find the differencies and similarities between cultured cells and in vivo ones, and evaluate the clinical applications of cultured tissue. Human gingiva was obtained and the specimen was explanted on 24-well plate. Two types of culture media were used in this culture system. One was for the growth of the keratinocytes (Media I), and the other was for the stratification (Media II). Media I had special ingredients for the epidermal growth. Those were 0.5% dimethyl sulfoxide (DMSO), 30ng/ml of epidermal growth factor (EGF), 30ng/ml of cholera toxin, and $5{\mu}g/ml$ of transferrin. We cultured the oral keratinocytes for 3 weeks, and at that time the cultured keratinocytes were processed to prepare the specimen for the TEM study. The results were as follows.; 1. In the phase contrast micrograph, epidermal outgrowth firstly appeared on the 3rd day after explantation, and the growing keratinocytes were activley mitotic, and had polygonal shape and increased N/C ratio. 2. In the phase contrast micrograph, the outer most cells exhibited areas where broad cytoplasmic processes extended out onto the culture subtratum(fan-like appaearance). 3. In the TEM micrographs, the cultured keratinocytes showed stratification. The cells were in elongated form, and there were no morphologic differencies among the layers usually found in the in vivo gingiva. 4. Most of cellular organelles underwent lysis, and keratohyaline granules were seen. Tonofibrils were dispersed in the cytoplasm. 5. The cells were interconnected by desmosomes, and their frequency of distribution was considered to be lower than that of in vivo keratinocytes. 6. We could conclude the cultured oral keratinocytes exhibited signs of terminal differentiation.

  • PDF