• Title/Summary/Keyword: Intensity level

Search Result 2,081, Processing Time 0.024 seconds

The Effects of Task Difficulty Controlled by Surface Condition During Bridging Exercise on Relative Multifidus Activation Ratio (교각 자세 운동 시 지지면 불안정성을 통한 과제 난이도가 다열근의 선택적 근활성도 비에 미치는 영향)

  • Song, Eun-Ju;Choi, Jong-Duk
    • Physical Therapy Korea
    • /
    • v.18 no.3
    • /
    • pp.59-66
    • /
    • 2011
  • The purpose of this study is to examine the activity ratios of global trunk muscles and local trunk muscles in relation to adjustments in the level of task difficulty while performing stability exercises in easily applied bridging lumbar stabilization exercise. Twenty healthy subjects performed bridging lumbar stabilization exercise while the level of task difficulty was plate was used in the same posture for all the exercises. EMG was used to examine the activity ratios of the global muscles and multifidus in relation to the level of task difficulty. Moreover, the activity ratios of the multifidus muscle, the erector spinae and the gluteus maximus muscle were measured. A one-way ANOVA with repeated measures was used, and a Bonferroni correction was conducted (${\alpha}$=.05). When the bridging lumbar stabilization exercise were performed at different difficulty levels, the activity of the multifidus muscle, which is a local muscle, was high in all three exercises. Also, compared to low intensity and intermediate intensity exercises, high intensity exercises showed more significant differences (${\alpha}$=.05). Among all the muscles, the multifidus showed the highest activity at intermediate intensity. Based on these results, we suggest that in the case of bridging lumbar stabilization exercise, low intensity or intermediate intensity exercises are more suitable and efficient for local muscle stabilization.

A Study on the Effects of the Reduction of Working Hours on Female Workers' Fatigue (근로시간 단축이 여성근로자의 피로도에 미치는 영향)

  • Lee, Bok-Im;Jung, Hye-Sun
    • Research in Community and Public Health Nursing
    • /
    • v.18 no.2
    • /
    • pp.276-283
    • /
    • 2007
  • Purpose: This present study has been conducted on female workers' shorter working hours in order to look into their fatigue level and the correlation between fatigue and working hours. Method: We surveyed 237 respondents using a questionnaire from June 1st to June 20th, 2005. Results: The means of total fatigue complaint was 3.45. The fatigue level was significantly higher in the lower age group, unmarried group, manager group and shorter working duration group. And the fatigue level was significantly correlated to working hours and work intensity. In the results of stepwise multiple regression, factors affecting the fatigue level were the change of work intensity, age, regular diet habit, working hours and the type of occupation. Conclusion: It is necessary to prepare the health promotion programs, which can reduce female workers' fatigue level and relieve the intensity of their works.

  • PDF

Developing a Non-Periodic Preventive Maintenance Model Guaranteeing the Minimum Reliability (최소 신뢰도를 보장하는 비 주기적 예방보전 모형 개발)

  • Lee, Juhyun;Ahn, Suneung
    • Journal of Applied Reliability
    • /
    • v.18 no.2
    • /
    • pp.104-113
    • /
    • 2018
  • Purpose: This paper proposes the non-periodic preventive maintenance policy based on the level of cumulative hazard intensity. We aim to construct a cost-effectiveness on the proposed model with relaxing the constraint on reliability. Methods: We use the level of cumulative hazard intensity as a condition variable, instead of reliability. Such a level of cumulative hazard intensity can derive the reliability which decreases as the frequency of preventive maintenance action increases. We also model the imperfect preventive maintenance action using the proportional age setback model. Conclusion: We provide a numerical example to illustrate the proposed model. We also analyze how the parameters of our model affect the optimal preventive maintenance policy. The results show that as long as high reliability is guaranteed, the inefficient preventive maintenance action is performed reducing the system operation time. Moreover, the optimal value of the proposed model is sensitive to changes in preventive maintenance cost and replacement cost.

Dimmable Spatial Intensity Modulation for Visible-light Communication: Capacity Analysis and Practical Design

  • Kim, Byung Wook;Jung, Sung-Yoon
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.532-539
    • /
    • 2018
  • Multiple LED arrays can be utilized in visible-light communication (VLC) to improve communication efficiency, while maintaining smart illumination functionality through dimming control. This paper proposes a modulation scheme called "Spatial Intensity Modulation" (SIM), where the effective number of turned-on LEDs is employed for data modulation and dimming control in VLC systems. Unlike the conventional pulse-amplitude modulation (PAM), symbol intensity levels are not determined by the amplitude levels of a VLC signal from each LED, but by counting the number of turned-on LEDs, illuminating with a single amplitude level. Because the intensity of a SIM symbol and the target dimming level are determined solely in the spatial domain, the problems of conventional PAM-based VLC and related MIMO VLC schemes, such as unstable dimming control, non uniform illumination functionality, and burdens of channel prediction, can be solved. By varying the number and formation of turned-on LEDs around the target dimming level in time, the proposed SIM scheme guarantees homogeneous illumination over a target area. An analysis of the dimming capacity, which is the achievable communication rate under the target dimming level in VLC, is provided by deriving the turn-on probability to maximize the entropy of the SIM-based VLC system. In addition, a practical design of dimmable SIM scheme applying the multilevel inverse source coding (MISC) method is proposed. The simulation results under a range of parameters provide baseline data to verify the performance of the proposed dimmable SIM scheme and applications in real systems.

Ground-to-air transmitted sound from shallow earthquakes

  • 이병호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.3-8
    • /
    • 1984
  • By one dimensional acoustic transmission from ground to air, the author has derived the level of sound caused by earthquakes. He has also tried to assign proper values of ground acceleration to the modified mercalli intensity scale and thence earthquake sound level to the intensity scale has been deduced as L\sub M/ = 79.6+6.0M, dB, where M is the earthquake magnitude in the modified Mercalli intensity scale.

  • PDF

The Effect of Frequency and Intensity of /a/ Phonation on the Result of Acoustic Analysis (발성시 음도 및 강도의 변화가 음성분석검사 결과에 미치는 영향)

  • 손영익;윤영선;권중근;추광철
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.12-17
    • /
    • 1997
  • Measuring phonatory stability using MDVP(Multi-dimensional voice program, Kay Elemetrics Corp., NJ, USA) are becoming popular in many Korean clinics and laboratories, yet questions about standardization and reference values have remained. The purpose of present study was to examine the effects of frequency and intensity variation on the results of acoustic analysis related to phonatory stability. Twenty young adults(ten females and ten males) were asked to sustain vowel /a/ for more than 3 seconds under 9 different pitch and loudness conditions. Using MDVP, nine voice samples were analyzed, and jitter percent, fundamental frequency variation, shimmer percent, peak amplitude variation, noise to harmonic ratio, amplitude tremor intensity index, and degree of subharmonics were compared. The results showed that intensity changes can significantly affect various phonatory stability measures, and the lowest perturbation values can be obtained from slightly louder(10dB) phonatory condition than comfortable level phonation.

  • PDF

A Kinetic Model of the Nonphotochemical Hole Burning : 3-Level System (비광화학적인 홀의 생성에 대한 속도론적 모델 : 유사 3-준위계)

  • Lee, In-Ja
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.10
    • /
    • pp.763-768
    • /
    • 1995
  • The theory previously proposed to simulate hole depth in the weak burn intensity limit is extended to examine the hole depth at arbitrary burn intensity using 3-level system model. The hole spectrum simulated using constant fluence gives different hole depth for strong burn intensity while it gives same hole depth for weak burn intensity region. The calculated hole growth curves are compared with published experimental data for oxazine720 in glycerol and tetracene in MTHF glass.

  • PDF

Intensity of Aerobic Exercise and Level of Cognitive Task on Computerized Neurobehavioral System

  • Kim, Tae-Hoon;Park, Ji-Hyuk;Kim, Jong-Eon
    • International Journal of Contents
    • /
    • v.6 no.3
    • /
    • pp.83-88
    • /
    • 2010
  • Aerobic exercise affects cerebral circulation, action of neurotransmitters, glucose, oxygen, and energetic substances and influence on the central nervous system for cognition. This study suggests that both the intensity of exercise and the level of cognitive task need to be considered. Computerized neurobehavioral testing is a more effective method, compared to conventional methods, of neuropsychological testing when measuring cognition objectively, in cases that we found. The intensity of 80% max HR had effect on more complex tasks such as 3 Digit Addition and Digit Span Backward, and the intensity of 65% max HR had an effect on more simple tasks such as Color Word Vigilance and Digit Span Forward. We can assume that different intensity of aerobic exercise might involve specific areas of the brain as they could have different sensitivities, so further studies measuring regional cerebral blood flow or electroencephalogram are needed to confirm the results.

Optimal Flood Control Volume in the Irrigation Reservoir (관개저수지의 적정 홍수조절용량 설정방법)

  • 김태철;문종필;민진우;이훈구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.2
    • /
    • pp.81-91
    • /
    • 1998
  • Water level of irrigation reservoir during the flood season could be kept to a certain level, so called, flood control level by releasing the flood inflow in advance in order to reduce the peak discharge of next coming flood and the damage of inundation. Concept of restriction intensity of water supply was introduced to evaluate the influence of flood control volume on the irrigation water supply. Restriction intensity can be calculated by multiplying the ratio of restriction to the days of restriction which are obtained from the operation rule curve and daily water level of irrigation reservoir and it has the dimension of % day. The method of restriction intensity was applied to the Yedang irrigation reservoir with the observed data of 30 years to review whether the present flood control volume is reasonable or not, and suggest the optimal flood control volume, if possible.

  • PDF

HID Ballast using Soft Switching Multi Level Inverter (Soft Switching Multi Level Inverter를 이용한 HID용 Ballast)

  • Lee Jang-Sun;Kim Yoon-Ho;Kim Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.628-634
    • /
    • 2004
  • The soft switching is applied to the multi-level inverter to enhance the characteristics of HID(High Intensity Discharge) Ballast in headlight of vehicle. The electrical properties are investigated. The available modeling of the ballast in steady-state is calculated using mathematical method and the result is used in analyzing the power characteristics and design of the system. Finally the designed system md modeling is confirmed by the experiment.