• Title/Summary/Keyword: Integrated interface

Search Result 970, Processing Time 0.027 seconds

A Research on the Proposal and Application of Data Model for an Integrated System of Reinforced Concrete Structures (철근 콘크리트 구조설계 통합시스템을 위한 데이터베이스 모델 제시와 응용)

  • 정윤철;천진호;서용표;이병해
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.342-351
    • /
    • 1998
  • The purpose of this study is to develop a central database and a database management system to store and manage information systematically from each module of an integrated structural design system. In order to efficiently express structural design process related to the data which is very complex, we used an object-oriented modeling methodology to propose the possibility to apply a database schema for application programs in an integrated system for reinforced concrete structural design. Based on this model, we developed an interface between each module and central database. After modeled by using object modeling technique, the database was mapped by the relational database table. Then the central database and the interface were programed by using Visual C/syo ++/, a windows environmental development tool.

  • PDF

Simulator of Integrated Single-Wafer Processing Tools with Contingency Handling (예외상황 처리를 고려한 반도체 통합제조장비 시뮬레이터)

  • Kim Woo Seok;Jeon Young Ha;Lee Doo Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.96-106
    • /
    • 2005
  • An integrated single-wafer processing tool, composed of multiple single wafer processing modules, transfer robots, and load locks, has complex routing sequences, and often has critical post-processing residency constraints. Scheduling of these tools is an intricate problem, and testing schedulers with actual tools requires too much time and cost. The Single Wafer Processor (SWP) simulator presented in this paper is to validate an on-line scheduler, and evaluate performance of integrated single-wafer processing tools before the scheduler is actually deployed into real systems. The data transfer between the scheduler and the simulator is carried out with TCP/IP communication using messages and files. The developed simulator consists of six modules, i.e., GUI (Graphic User Interface), emulators, execution system, module managers, analyzer, and 3D animator. The overall framework is built using Microsoft Visual C++, and the animator is embodied using OpenGL API (Application Programming Interface).

ISDN (종합정보통신망)

  • 정기성
    • Product Safety
    • /
    • s.61
    • /
    • pp.68-71
    • /
    • 1998
  • ISDN(Integrated Services Digital Network)은 종합정보통신망이라 명명되었으며 그 이름에서 내포하듯이 음성정보와 각종 멀티미디어 정보를 함께 보내고 받을 수 있는 통신망이다. 기본적인 서비스인 BRI(Basic Rate Interface)는 2개의 정보채널에 각각 64kbps 속도의 통신 서비스이며 규모 있는 회사에 보급되는 PRI(Primary Rate Interface)는 30개의 정보채널을 제공한다.

  • PDF

Integrated 3-Channel Flux-Locked-Loop Electronics for the Readout of High-$T_c$ SQUID (고온초전도 SQUID 신호 검출을 위한 3채널용 FLL 회로)

  • 김진목;김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.55-60
    • /
    • 2003
  • We designed and constructed integrated 3-channel flux-locked-loop (FLL) electronic system for the control and readout of high-T$_{c}$ SQUIDs. This system consists of low noise preamplifiers, integrators, interface circuits, and software. FLL operation was carried out with biased signals of 19 KHz modulated current and 150 KHz modulated flux, which are reconstructed as detected signals by preamplifier and demodulator. Computer controlled interface circuits regulate FLL circuit and adjust SQUID parameters to the optimum operating condition. The software regulates interface circuits to make an auto-tuning for the control of SQUIDs, and displays readout data from FLL circuit. 3-channel SQUID electronic system was assembled with 3 FLL-interface circuit boards and a power supply board in the aluminum case of 56 mm ${\times}$ 53 mm${\times}$ 150 mm. Overall noise of the system was around 150 fT/(equation omitted)Hz when measured in the shielded room, 200 fT/(equation omitted)Hz in a weakly shielded room, respectively.y.

  • PDF

Access Point Interface Configuration using Radio over Fiber for the WIBRO System (WIBRO 시스템의 Radio over Fiber에 의한 Access Point 접속구도)

  • Song, Ju-Bin;Kim, Young-Il
    • Journal of Advanced Navigation Technology
    • /
    • v.9 no.2
    • /
    • pp.93-102
    • /
    • 2005
  • This paper presents an interface configuration between Access Point(AP) and Radio Over Fiber (ROF) transceiver for the wireless internet system. The wireless internet could provides 60km/h mobility and 50Mbps IP based data services for each mobile terminal. Thus, cost effective cell infrastructure is inevitably required. This paper suggests an interface configuration between AP and passive integrated picocell(PIP) involving ROF links. Nonlinear characteristics of ROF link using a typical FP transceiver are measured for wireless internet applications.

  • PDF

A study on the Interface Evaluation Guidelines for Integrated Information Retrieval System (통합정보검색시스템의 인터페이스 평가지표에 관한 연구)

  • Lee, Too-Young;Yoon, Dae-Jin
    • Journal of the Korean Society for information Management
    • /
    • v.20 no.3
    • /
    • pp.177-197
    • /
    • 2003
  • The purpose of this study is to suggest the subject and standards of evaluation on integrated IR interface. For this study, we studied the preceding research about major IR interface models. We took the survey for interface elements which were verified by experts. These interface elements are divided twe viewpoints. One is the cognitive viewpoints which are the page design, content design, site design, output form, usability and aesthelic facet. The other is the objective viewpoints which are page design, dontent design, site design, output for and usability. We found that these evaluation elements have a crediblilty.

An Integrated Interface based on CIM between Energy Management System and Heterogeneous Systems (에너지 관리 시스템(EMS)과 이기종 시스템간 CIM 기반의 통합 인터페이스)

  • Kang, Dong Hyun;Lee, Yong Ik;Park, Jong Ho;Shin, Yong-Hack
    • Journal of Software Engineering Society
    • /
    • v.24 no.3
    • /
    • pp.111-115
    • /
    • 2011
  • With the emergence of the smart grid era, the interest in green energy which reduce carbon emissions and environment-friendly smart grid which combines the advantages of power and IT technology is increasing around the world. To use the smart grid effectively heterogeneous systems such as EMS, MOS and WIS must be linked together. However, additional interface should be developed to link EMS and heterogeneous systems since IEC has only defines the interface for EMS. Especially, to link legacy system and new system, some software might need to be designed and developed because separate interfaces for connection can be developed depending on each system and environment. In this paper, we propose an integrated interface based on CIM for interconnection between systems. A proposed interface can integrate messages of heterogeneous system and will be able to reduce costs that could be incurred by the removal of the existing system and the addition of the new system.

  • PDF

Digitized Pressure Sensor (디지탈 출력 압력 센서)

  • Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.419-421
    • /
    • 1996
  • We propose the digitized pressure sensor and the interface circuit to read directly the pressure signal in the digital form. The interface circuit has the control clock, comparator, and bit value decision circuit. The digitized sensor and interface circuit are integrated on the one chip using the post processing after IC fabrication. The dimension of the fabricated digitized pressure sensor is $3{\times}6{\times}1mm^3$.

  • PDF

Evaluation of a Self-Adaptive Voltage Control Scheme for Low-Power FPGAs

  • Ishihara, Shota;Xia, Zhengfan;Hariyama, Masanori;Kameyama, Michitaka
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.3
    • /
    • pp.165-175
    • /
    • 2010
  • This paper presents a fine-grain supply-voltage-control scheme for low-power FPGAs. The proposed supply-voltage-control scheme detects the critical path in real time with small overheads by exploiting features of asynchronous architectures. In an FPGA based on the proposed supply-voltage-control scheme, logic blocks on the sub-critical path are autonomously switched to a lower supply voltage to reduce the power consumption without system performance degradation. Moreover, in order to reduce the overheads of level shifters used at the power domain interface, a look-up-table without level shifters is employed. Because of the small overheads of the proposed supply-voltage-control scheme and the power domain interface, the granularity size of the power domain in the proposed FPGA is as fine as a single four-input logic block. The proposed FPGA is fabricated using the e-Shuttle 65 nm CMOS process. Correct operation of the proposed FPGA on the test chip is confirmed.

Development of Flooding area estimation module for Rubber-tired Tram Disaster Management System Using the SWMM Model (SWMM 모형을 이용한 홍수시 바이모달 트램 운행 노선에 대한 침수 면적 산정 모듈 개발)

  • Kim, Jong-Gun;Park, Young-Kon;Yoon, Hee-Taek;Park, Youn-Shik;Jang, Won-Seok;Yoo, Dong-Seon;Lim, Kyoung-Jae
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.61-65
    • /
    • 2008
  • Urban flooding with surcharges in sewer system was investigated because of unexpected torrential storm events these days, causing significant amounts of human and economic damages. Although there are limitations in forecasting and preventing natural disasters, integrated urban flooding management system using the SWMM engine and Web technology will be an effective tool in securing safety in operating Bi-modal transportation system. In addition, the integrated urban flooding management system can be linked with general and transportation-related disaster management system in the future. In this study, With simulated values by the SWMM, which is a core engine of the Bi-modal disaster management system, flash flooding area estimation module was developed. Thus, the SWMM system codes were modified and new module was developed and integrated with the existing SWMM interface using the Delphi programming language. The flash flooding area estimation module is fully integrated with the SWMM interface, thus the area is estimated on-the-fly inside the system.

  • PDF