• Title/Summary/Keyword: Integrated Protection

Search Result 501, Processing Time 0.032 seconds

Study on the integrated information system of Sapporo subway (삿포로 지하철 종합정보시스템에 관한 고찰)

  • Cho, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.237-239
    • /
    • 2004
  • Sapporo subway sets up the integrated information system to be aim at the effective and automatic work from the first time. They are expanding integrated system by introducing IT into Serve system positively which developed for recent several years. To keep up with the big size and high speed of information according to integrated system,. the integrated transmission line system which is basic of the integrated system is changed into the system which apply the newest technology. Also, they are aimed at the next generation traffic system through the cooperation of the local administration, for example, test of the multipurpose card using non-contact IC card. This study reviewed the present state of Sapporo subway, the upgrade of information transmission system, and the function of each serve system those are the order of equipment, management of the running, management of the disaster presentation, signal protection, passenger management etc.

  • PDF

A Study on the Design of the Output ESD Protection Circuits and their Electrical Characteristics (출력단 ESD 보호회로의 설계 및 그 전기적 특성에 관한 연구)

  • 김흥식;송한정;김기홍;최민성;최승철
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.11
    • /
    • pp.97-106
    • /
    • 1992
  • In integrated circuits, protection circuits are required to protect the internal nodes from the harmful ESD(Electrostatic discharge). This paper discusses the characteristics of the circuit components in ESD protection circuitry in order to analyze the ESD phenomina, and the design methodalogy of ESD protection circuits, using test pattern with a variation of the number of diode and transistor. The test devices are fabricated using a 0.8$\mu$m CMOS process. SPICE simulation was also carried out to relate output node voltage and measured ESD voltage. With increasing number of diodes and transistors in protection circuit, the ESD voltage also increases. The ESD voltage of the bi-directional circuit for both input and output was 100-300[V], which in higher than that of only output(uni-directional) circuit. In addition, the ESD protection circuit with the diode under the pad region was useful for the reduction of chip size and parasitic resistance. In this case, ESD voltage was improved to a value about 400[V].

  • PDF

Adaptive undervoltage protection scheme for safety bus in nuclear power plants

  • Chang, Choong-koo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2055-2061
    • /
    • 2022
  • In the event of a short-circuit accident on a 4.16 kV non-safety bus, the voltage is temporarily lowered as backflow occurs on the safety bus. In such cases, the undervoltage relay of the safety bus shall not pick up the undervoltage so as not to interfere with the operation of the safety motors. The aim of this study is to develop an adaptive undervoltage protection scheme for the 4.16 kV safety bus considering the faults on the 13.8 kV and 4.16 kV non-safety buses connected to secondary windings of the three winding transformers, UAT and SAT. The result of this study will be the adaptive undervoltage protection scheme for the safety bus of nuclear power plants satisfying functional requirements of the safety related medium voltage motors. The adaptive undervoltage protection scheme can be implemented into an integrated digital protective relay to make user friendly and reliable protection scheme.

A Study on Proposals for Improving the Fire Protection Regulations for Nuclear Power Plants (원자력발전소 화재방호 규제 개선 방향에 관한 연구)

  • Ma, Jin-Soo;Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.116-122
    • /
    • 2010
  • The fire protection system of nuclear power plants shall be designed, constructed and operated, through a defense-in depth criterion to suppress the leakage of radioactivity to the outside and to allow the safety shutdown function when a fire occurs. In order to achieve these purposes, most of countries abroad operating the nuclear power plants keep up the integrated regulations, however we have two guidelines, the fire protection service act and the nuclear energy act, as mandatory requirements to apply to the fire protection systems in nuclear power plants. It has shown that USA, Canada and Japan which have long experience in operating nuclear power plants have regulations integrated technically for fire protection system of nuclear power plants. It is proposed that the things once verified the risk analysis of the fire hazard by the nuclear law in the design for fire suppression system in plants should be authorized by the fire protection service act as an exception.

Case Analysis to Establish an Integrated Care System for Seniors (노인 통합케어 시스템 구축을 위한 사례분석)

  • Yoo, Yong-Shik
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.2
    • /
    • pp.367-375
    • /
    • 2011
  • This study conducts analysis on integrated care cases in Korea and other nations regarding health, medical, and welfare services that are segmented and fragmented in order to provide foundational data to establish an integrated care system appropriate for the situation of Korea. According to the result of the cases, integrated care provides various services in common through cooperation with organizations, collaborative participation of various professionals, provision of intervention and individualized protection, and experts for taking care of the cases. Based on those cases, this paper provides suggestions to establish an integrated care system of Korea. In fact, it is necessary to build integrated care general support centers, arrange service providing places in common, establish a care management system, develop resources and expand manpower, develop an integrated care case management system, and develop integrated care computer network.

Design of Power Factor Correction IC for 1.5kW System Power Module (1.5kW급 System Power Module용 Power Factor Correction IC 설계)

  • Kim, Hyoung-Woo;Seo, Kil-Soo;Kim, Ki-Hyun;Park, Hyun-Il;Kim, Nam-Kyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.499-500
    • /
    • 2008
  • In this paper, we design and implement the monolithic power factor correction IC for system power modules using a high voltage(50V) CMOS process. The power factor correction IC is designed for power applications, such as refrigerator, air-conditioner, etc. It includes low voltage logic, 5V regulator, analog control circuit, high-voltage high current output drivers, and several protection circuits. And also, the designed IC has standby detection function which detects the output power of the converter stage and generates system down signal when load device is under the standby condition. The simulation and experimental results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

Analysis of the LIGBT-based ESD Protection Circuit with Latch-up Immunity and High Robustness (래치-업 면역과 높은 감내 특성을 가지는 LIGBT 기반 ESD 보호회로에 대한 연구)

  • Kwak, Jae Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.686-689
    • /
    • 2014
  • Electrostatic discharge has been considered as a major reliability problem in the semiconductor industry. ESD reliability is an important issue for these products. Therefore, each I/O (Input/Output) PAD must be designed with a protection circuitry that creates a low impedance discharge path for ESD current. This paper presents a novel Lateral Insulated Gate Bipolar (LIGBT)-based ESD protection circuit with latch-up immunity and high robustness. The proposed circuit is fabricated by using 0.18 um BCD (bipolar-CMOS-DMOS) process. Also, TLP (transmission line pulse) I-V characteristic of proposed circuit is measured. In the result, the proposed ESD protection circuit has latch-up immunity and high robustness. These characteristics permit the proposed circuit to apply to power clamp circuit. Consequently, the proposed LIGBT-based ESD protection circuit with a latch-up immune characteristic can be applied to analog integrated circuits.

Performance Test of an Integrated Electronic Protection Device Based Photovoltaic Inverter (지능형 보호기기 적용 태양광 인버터 성능시험)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1744-1750
    • /
    • 2007
  • This paper addresses grid interconnection tests of a 3kW transformer-less photovoltaic (PV) inverter to verify the effectiveness of the PV inverter and promote its wide use. The 3kW transformer-less PV inverter, which was equipped with intelligent protection and control system, was manufactured. A hardware test bed was constructed for performance tests of the PV inverter. Control performance and grid protection tests were carried out using the test bed. Test results verify the performance of the power control and grid protection functions of the developed transformer-less PV inverter.

Software Verification & Validation for Digital Reactor Protection System (디지털 원자로 보호계통의 소프트웨어 확인 및 검증)

  • Park, Gee-Yong;Kwon, Kee-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.185-187
    • /
    • 2005
  • The reactor protection system is the most important function for the safe operation of nuclear powerplants (NPPs) in that such system protects a nuclear reactor tore whose damage can cause an enormous disaster to the nuclear facility and the public. A digital reactor protection system (DRPS) is being developed in KAERI for use in the newly-constructed NPPs and also for replacing the existing analog-type reactor Protection systems. In this paper, an software verification and validation (V&V) activities for DRPS, which are independent of the DRPS development processes, are described according to the software development life cycle. The main activities of DRPS V&V processes are the software planning documentations, the verification of software requirements specification (SRS) and software design specification (SDS), the verification of codes, the tests of the integrated software and system. Moreover, the software safety analysis and the software configuration management are involved in the DRPS V&V processes. All of the V&V activities are described, in detail, in this paper.

  • PDF