• Title/Summary/Keyword: Integrated M&S

Search Result 865, Processing Time 0.026 seconds

Fully Integrated Electromagnetic Noise Suppressors Incorporated with a Magnetic Thin Film on an Oxidized Si Substrate

  • Sohn, Jae-Cheon;Han, S.H.;Yamaguchi, Masahiro;Lim, S.H.
    • Journal of Magnetics
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • Si-based electromagnetic noise suppressors on coplanar waveguide transmission lines incorporated with a $SiO_2$ dielectric layer and a nanogranular Co-Fe-Al-O magnetic thin film are reported. Unlike glass-based devices, large signal attenuation is observed even in the bare structure without coating the magnetic thin film. Much larger signal attenuation is achieved in fully integrated devices. The transmission scattering parameter ($S_{21}$) is as small as -90 dB at 20 GHz at the following device dimensions; the thicknesses of the $SiO_2$ and Co-Fe-Al-O thin films are 0.1 $\mu$m and 1 $\mu$m, respectively, the length of the transmission line is 15 mm, and the width of the magnetic thin film is 2000 $\mu$m. In all cases, the reflection scattering parameter ($S_{11}$) is below -10 dB over the whole frequency band. Additional distributed capacitance formed by the Cu transmission line/$SiO_2$/Si substrate is responsible for these characteristics. It is considered that the present noise suppressors based on the Si substrate are a first important step to the realization of MMIC noise suppressors.

3D Lithography using X-ray Exposure Devices Integrated with Electrostatic and Electrothermal Actuators

  • Lee, Kwang-Cheol;Lee, Seung S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.4
    • /
    • pp.259-267
    • /
    • 2002
  • We present a novel 3D fabrication method with single X-ray process utilizing an X-ray mask in which a micro-actuator is integrated. An X-ray absorber is electroplated on the shuttle mass driven by the integrated micro-actuator during deep X-ray exposures. 3D microstructures are revealed by development kinetics and modulated in-depth dose distribution in resist, usually PMMA. Fabrication of X-ray masks with integrated electrothermal xy-stage and electrostatic actuator is presented along with discussions on PMMA development characteristics. Both devices use $20-\mu\textrm{m}$-thick overhanging single crystal Si as a structural material and fabricated using deep reactive ion etching of silicon-on-insulator wafer, phosphorous diffusion, gold electroplating, and bulk micromachining process. In electrostatic devices, $10-\mu\textrm{m}-thick$ gold absorber on $1mm{\times}1mm$ Si shuttle mass is supported by $10-\mu\textrm{m}-wide$, 1-mm-long suspension beams and oscillated by comb electrodes during X-ray exposures. In electrothermal devices, gold absorber on 1.42 mm diameter shuttle mass is oscillated in x and y directions sequentially by thermal expansion caused by joule heating of the corresponding bent beam actuators. The fundamental frequency and amplitude of the electrostatic devices are around 3.6 kHz and $20\mu\textrm{m}$, respectively, for a dc bias of 100 V and an ac bias of 20 VP-P (peak-peak). Displacements in x and y directions of the electrothermal devices are both around $20{\;}\mu\textrm{m}$at 742 mW input power. S-shaped and conical shaped PMMA microstructures are demonstrated through X-ray experiments with the fabricated devices.

The Design of Integrated Flying Vehicle Model for Engagement Analyses of Missiles

  • Ha, Sue Hyung
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.8
    • /
    • pp.930-939
    • /
    • 2019
  • High-Level Architecture(HLA)/Run-Time Infrastructure(RTI) are standards for distributed simulation systems and offer a technology to interconnect them and form one single simulation system. In defense domain, M&S is the only way to prove effectiveness of weapon systems except for Live Fire Testing (LFT). This paper focuses on guided missile simulations in weapon systems for engagement analyses and proposes the integrated flying vehicle model that is based on HLA/RTI. There are a lot of missiles in real world; therefore, we should develop each missile models in M&S in order to apply battlefield scenarios. To deal with the difficulties, in this paper, firstly, I classify these missiles into three models: ballastic, cruise, and surface-to-air missile models, and then I design each missile model and integrates them into a single model. This paper also offers a case study with my integrated flying vehicle model. At the conclusion, this paper presents contributions of this paper.

Modeling & Simulation Software Design for Coverage Analysis of Multiple Radio Positioning Integration System

  • Koo, Moonsuk;Kim, YoungJoon;So, Hyoungmin;Oh, Sang Heon;Kim, Seong-Cheol;Hwang, Dong-Hwan
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.5 no.2
    • /
    • pp.47-57
    • /
    • 2016
  • Since the Global Navigation Satellite System (GNSS) may not provide navigation information due to external interferences, many countries have plans to prepare a backup system for this situation. One of the possible GNSS backup systems is a multiple radio positioning integration system in combination with the terrestrial radio navigation system. Before constructing such a GNSS backup system, M&S software is needed to analyze if the system satisfies the performance the required navigation performance. This study presents requirements of M&S software for coverage analysis of the navigation system, and proposes an M&S software design scheme on the basis of the requirements. The M&S software is implemented, and coverage analysis is performed to verify the validity of the proposed design scheme.

Covalent Immobilization of Diaphorase in Viologen Polymer Network for Highly Sensitive Detection of NAD+ and NADH

  • Song, Jieun;Hong, Zhenyu;Koh, Ahyeon;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.19-22
    • /
    • 2014
  • Here we report a highly sensitive and stable detection of $NAD^+$ and NADH by the electrode on which diaphorase (DI) is covalently immobilized in viologen polymer network. The network is prepared by the covalent formation of the structure by mixing propylamine viologen (PAV), poly(ethylene glycol)(400) diglycidyl ether (PEGDGE), an diaphorase (DI). The PAV/PEGDGE/DI modified electrode has the sensitivity of $0.02nA{\cdot}{\mu}M$ and the detection limit of $3{\mu}M$ with a response time of 2 s ($t_{90%}$) for NADH sensing.

A Study on Ward of Public Hospital for Spatial Composition of Efficient Integrated Nursing Care Service - Focused on the Regional Public Hospital - (효율적 간호·간병통합서비스 공간 조성을 위한 공공병원 병동부에 관한 연구 - 지역거점 지방의료원을 중심으로 -)

  • Han, Suk-Bum;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.6
    • /
    • pp.71-80
    • /
    • 2017
  • The purpose of this study is identify the status of the ward of public hospital for integrated nursing care service. Integrated nursing care service has been expanding on a national scale from 2016 but most of public hospitals are currently unable to operate due to nursing shortage. In this study 8 wards of public hospital have been chosen and analyzed. The measure of space program and area distribution(patient area percentage, staff area percentage, circulation area percentage), nurses's walking distance(distance from ns to patient room, distance from ns to core) were calculated by depthmapX and autocad programs. The result of this study is as follows. Nurse's walking distance is more than 24m so the efficiency of nurse's patient care is reduced. The percentage of patient area in double-corridor is higher and the patient feels more comfortable but the Nurse's walking distance is longer and the accessibility is lowered. NS should be located in the center of the ward and close to the core but some wards are not composed of proper space-separation and flow of human trrafic is overlapped. This study may serve as basic research for the architectural plan for future integrated nursing care ward.

A 10b 100 MSample/s $1.4\;mm^2$ 56 mW 0.18 urn CMOS A/D Converter for Low-Power Multimedia Applications (저전력 멀티미디어 응용을 위한 10b 100 MSample/s $1.4\;mm^2$ 56 mW 0.18 um CMOS A/D 변환기)

  • Min Byoung-Han;Park Hee-Won;Chae Hee-Sung;Sa Doo-Hwan;Lee Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.53-60
    • /
    • 2005
  • This work proposes a 10b 100 MS/s $1.4\;mm^2$ CMOS ADC for low-power multimedia applications. The proposed two-step pipeline ADC minimizes chip area and power dissipation at the target resolution and sampling rate. The wide-band SHA employs a gate-bootstrapping circuit to handle both single-ended and differential inputs with 1.2 Vp-p at 10b accuracy while the second-stage flash ADC employs open-loop offset sampling techniques to achieve 6b resolution. A 3-D fully symmetrical layout reduces the capacitor and device mismatch of the first-stage MDAC. The low-noise references are integrated on chip with optional off-chip voltage references. The prototype 10b ADC implemented in a 0.18 um CMOS shows the maximum measured DNL and INL of 0.59 LSB and 0.77 LSB, respectively. The ADC demonstrates the SNDR of 54 dB, the SFDR of 62 dB, and the power dissipation of 56 mW at 100 MS/s.

Studies on the High-gain Low Noise Amplifier for 60 GHz Wireless Local Area Network (60 GHz 무선 LAN의 응용을 위한 고이득 저잡음 증폭기에 관한 연구)

  • 조창식;안단;이성대;백태종;진진만;최석규;김삼동;이진구
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.11
    • /
    • pp.21-27
    • /
    • 2004
  • In this paper, millimeter-wave monolithic integrated circuit(MIMIC) low noise amplifier(LNA) for V-band, which is applicable to 60 GHz wireless local area network(WLAN), was fabricated using the high performance 0.1 ${\mu}{\textrm}{m}$ $\Gamma$-gate pseudomorphic high electron mobility transistor(PHEMT). The DC characteristics of PHEMT are drain saturation current density(Idss) of 450 mA/mm and maximum transconductance(gm, max) of 363.6 mS/mm. The RF characteristics were obtained the current gain cut-off frequency(fT) of 113 GHz and the maximum oscillation frequency(fmax) of 180 GHz. V-band MIMIC LNA was designed using active and passive device library, which is composed of 0.1 ${\mu}{\textrm}{m}$ $\Gamma$-gate PHEMT and coplanar waveguide(CPW) technology. The designed V-band MIMIC LNA was fabricated using integrated unit processes of active and passive device. The measured results of V-band MIMIC LNA are shown S21 gain of 21.3 dB, S11 of -10.6 dB at 60 GHz and S22 of -29.7 dB at 62.5 GHz. The measured result of V-band MIMIC LNA was shown noise figure (NF) of 4.23 dB at 60 GHz.

Chitosan-Cu-salen/Carbon Nano-Composite Based Electrode for the Enzyme-less Electrochemical Sensing of Hydrogen Peroxide

  • Jirimali, Harishchandra Digambar;Saravanakumar, Duraisamy;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.169-175
    • /
    • 2018
  • Cu-Salen complex was prepared and attached into chitosan (Cs) polymer backbone. Nanocomposite of the synthesized polymer was prepared with functionalized carbon nano-particles (Cs-Cu-sal/C) to modify the electrode surface. The surface morphology of (Cs-Cu-sal/C) nanocomposite film showed a homogeneous distribution of carbon nanoparticles within the polymeric matrix. The cyclic voltammogram of the modified electrode exhibited a redox behavior at -0.1 V vs. Ag/AgCl (3 M KCl) in 0.1 M PB (pH 7) and showed an excellent hydrogen peroxide reduction activity. The Cs-Cu-sal/C electrode displays a linear response from $5{\times}10^{-6}$ to $5{\times}10^{-4}M$, with a correlation coefficient of 0.993 and detection limit of $0.9{\mu}M$ (at S/N = 3). The sensitivity of the electrode was found to be $0.356{\mu}A\;{\mu}M^{-1}\;cm^{-2}$.

Integrated Phytoplankton Data of the west Pacific Sector of the Southern Ocean: $140-148 ^{\circ}E$ transect

  • Hak Young Lee;In
    • Journal of Environmental Science International
    • /
    • v.2 no.1
    • /
    • pp.21-28
    • /
    • 1993
  • A total of 94 taxa were identified from the Southern Ocean, 140-148 。E and 40-53。S, as an early austral summer phytoplankton. They were 53 diatoms, 37 dinoflagellates, 2 silicoflagellates, 1 prymnesiophyte, and 1 coccolithophorid. Integrated cell numbers of nanoplankton dominated microphytoplankton from 8 stations, especially from Subantarctic zone, but integrated biomass was lower than microphytoplankton. Integrated cell numbers of diatoms dominated dinoflagellates, coccolithophorids, and pnrnnesiophyte, but integrated biomass of microphytoplankton were dependent to the biomass of dinoflagellates except north of the Subtropical convergence zone and south of the Antractic convergence sone. Phytoplankton community changed across the fronts and 3 different communities were observed. Fronts seem to influence on the phytoplankton community from the west Pacific Sector of the Southern Ocean.

  • PDF