• Title/Summary/Keyword: Integrated M&S

Search Result 870, Processing Time 0.032 seconds

A Study on Electrical Properties of Dendrimer (미소전극형 DNA칩 어레이를 이용한 유전자의 검출)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1324-1326
    • /
    • 2006
  • In this study, an integrated microelectrode array was fabricated on glass slide using microfabrication technology. Probe DNAs consisting of mercaptohexyl moiety at their 5-end were spotted on the gold electrode using micropipette or DNA arrayer utilizing the affinity between gold and sulfur. Cyclic voltammetry in 5mM ferricyanide/ferrocyanide solution at 100 mV/s confirmed the immobilization of probe DNA on the gold electrodes. When several DNAs were detected electrochemically, there was a difference between target DNA and control DNA in the anodic peak current values. It was derived from specific binding of Hoechst 33258 to the double stranded DNA due to hybridization of target DNA. It suggested that this DNA chip could recognize the sequence specific genes. It suggested that multichannel electrochemical DNA microarray is useful to develop a portable device for clinical gene diagnostic system.

  • PDF

High-performance 94 GHz MMIC Low Noise Amplifier using Metamorphic HEMTs (Metamorphic HEMT를 이용한 우수한 성능의 94 GHz MMIC 저잡음 증폭기)

  • Kim, Sung-Chan;An, Dan;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.8
    • /
    • pp.48-53
    • /
    • 2008
  • In this paper, we developed the MMIC low noise amplifier using 100 nm metamorphic HEMTs technology in combination with coplanar circuit topology for 94 GHz applications. The $100nm\times60{\mu}m$ MHEMT devices for the MMIC LNA exhibited DC characteristics with a drain current density of 655 mA/mm, an extrinsic transconductance of 720 mS/mm. The current gain cutoff frequency $(f_T)$ and maximum oscillation frequency $(f_{max})$ were 195 GHz and 305 GHz, respectively. The realized MMIC LNA represented $S_{21}$ gain of 14.8 dB and noise figure of 4.6 dB at 94 GHz with an over-all chip size of $1.8mm\times1.48mm$.

Analysis on the Pitch Response Spectra of a Catamaran with Bulb (벌브를 가진 쌍동형 선박의 종동요 응답 스펙트럼 분석)

  • Seo, Kwang-Cheol;Lee, Chang-Woo;Atlar, Mehmt;Lee, Gyoung-Woo;Gim, Ok-Sok
    • Journal of Navigation and Port Research
    • /
    • v.37 no.5
    • /
    • pp.481-486
    • /
    • 2013
  • In this study, a commercial seakeeping program Seakeeper, integrated into Maxsurf, which is based on the linear strip theory was employed to compare the effect of bulbous bow (with/without) on motion response characteristics in a 18-meter catamaran. The seakeeping analyses were conducted at several Beaufort wind conditions such as scale No. 3 ($\bar{T}=2.98s$, $H_{1/3}$ =0.6m), No. 4 ($\bar{T}=3.85s$, $H_{1/3}$ =1m) and No. 5 ($\bar{T}=5.44$, $H_{1/3}$ =2m) based on ITTC wave spectrum. Pitch motion response spectrum was calculated at Head sea, Head & bow sea and Beam sea as encounter angles. Hull form of a catamaran with bulb showed the maximum 20% decrease of pitch motion response as compared to that of hull form without bulb.

High-performance of Flexible Supercapacitor Cable Based on Microwave-activated 3D Porous Graphene/Carbon Thread (마이크로웨이브 활성화 3차원 다공성 그래핀/탄소실 기반의 고성능 플렉서블 슈퍼커패시터 케이블)

  • Park, Seung Hwa;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.23-28
    • /
    • 2019
  • We report a supercapacitor cable, which consists of three-dimensional (3D) porous graphene coated onto the surface of carbon thread. The 3D porous framework of graphene was constructed by microwave-activated process using a graphene oxide-coated carbon thread. The use of microwave irradiation enabled to convert graphene oxide into reduced graphene oxide without any reducing agents and activate graphene sheets into exfoliated and porous graphene sheets. Combining two wire electrodes with a polymer gel electrolyte successfully completed supercapacitor device in a form of cable construction. The supercapacitor cables were highly flexible, and thus can be transformed into various shapes of devices and be integrated into textile items. A high area-capacitance of 38.1 mF/cm was obtained at a scan rate of 10 mV/s. This capacitance was retained 88% of its original value at 500 mV/s. The cycle life was also demonstrated by repeating a charge/discharge process during 10,000 cycles even under bent states, showing a high capacitance retention of 96.5%.

A Case Report on the Use of M&L Psychotherapy for Chronic Pain Patients through a Traditional Korean Psychiatric Therapeutic Approach (한의정신치료적 접근을 통한 만성통증 환자의 M&L 심리치료 활용 1례 보고)

  • Hyun-A Sim;Jin-Hyun Kim;Jae, kyoung Lee;Soo-Duk Kim;Young-Tak Koh
    • Journal of Oriental Neuropsychiatry
    • /
    • v.35 no.3
    • /
    • pp.279-289
    • /
    • 2024
  • Objectives: To report effects of M&L psychotherapy combined with Korean medical treatments on a patient with chronic low back pain. Methods: We treated a patient with chronic low back pain using M&L psychotherapy alongside a combination of Korean medical treatments, which included acupuncture, pharmacopuncture, cupping, and herbal medicine. The patient was diagnosed based on the ICD-11 diagnostic criteria for chronic primary pain. To evaluate the patient's progress, we used the Numerical Rating Scale (NRS), Oswestry Disability Index (ODI), Visual Analogue Scale (VAS), Beck's Depression Inventory (BDI), and Beck's Anxiety Inventory (BAI). Results: After three weeks of inpatient treatment and two months of outpatient treatment, the patient showed significant improvement in both pain and psychological symptoms. The NRS score decreased from 7 to 2. The BDI score decreased from 54 to 11 and the BAI score decreased from 33 to 9. Conclusions: This study demonstrates that M&L psychotherapy combined with Korean medical treatments can significantly reduce chronic low back pain and improve psychological symptoms such as depression and anxiety. The patient's notable improvements in NRS, BDI, and BAI scores suggest that an integrated treatment approach addressing both physical and mental health aspects is effective for managing chronic pain. These findings support potential benefits of holistic and multidisciplinary strategies for treating patients with chronic pain.

A 20 GHz Band 1 Watt MMIC Power Amplifier (20 GHz대 1 Watt 고출력증폭 MMIC의 설계 및 제작)

  • 임종식;김종욱;강성춘;남상욱
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1044-1052
    • /
    • 1999
  • A 2-stage 1 watt MMIC(Monolithic Microwave Integrated Circuits) HPA(High Power Amplifiers) at 20 GHz band has been designed and fabricated. The $0.15\mu\textrm{m}$ with the width of $400\mu\textrm{m}$for single device pHEMT technology was used for the fabrication of this MMIC HPA. Due to the series feedback technique from source to ground, bias circuits and stabilization circuits on the main microstrip line, the stability factors(Ks) are more than one at full frequency. The independent operation for each stage and excellent S11, S22 less than -20 dB have been obtained by using lange couplers. For beginning the easy design, linear S-parameters have been extracted from the nonlinear equivalent circuit in foundry library, and equivalent circuits of devices at in/output ports were calculated from this S-parameters. The measured performances, which are in well agreement with the predicted ones, showed the MMIC HPA in this paper has the minimum 15 dB of linear gain, -20 dB of reflection coefficients and 31 dBm of output power over 17~25 GHz.

  • PDF

A Development of Web-based Safety Evaluation System of Motor-Operated-Valve in Nuclear Power Plant (웹기반 원전 동력구동밸브 안정성 평가 시스템 개발)

  • Bae, J.H.;Lee, K.N.;Kim, W.M.;Park, S.K.;Lee, D.H.;Kim, J.C.;Hong, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.903-908
    • /
    • 2001
  • A web-based client/server program, MOVIDIK(Motor-Operated-Valve Integrated Database Information of KEPCO) has been developed to perform a design basis safety evaluation for a motor-operated-valve(MOV) in the nuclear power plant. The MOVIDIK consists of seven analysis modules and one administrative module. The analysis module calculates a differential pressure on the valve disk, thrust/torque acting at a valve stem, maximum allowable stress, thermal-overload-relay selection, voltage degradation, actuator output and margin. In addition, the administrative module manages user information, approval system and code information. MOVIDIK controls a huge amount of evaluation data and piles up the safety information of safety-related MOV. The MOVIDIK will improve the efficiency of safety evaluation work and standardize the analysis process for the MOV.

  • PDF

Dual-Toehold-Probe-Mediated Exonuclease-III-Assisted Signal Recycles Integrated with CHA for Detection of mecA Gene Using a Personal Glucose Meter in Skin and Soft Tissue Infection

  • Jiaguang Su;Wenjun Zheng
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.12
    • /
    • pp.1692-1697
    • /
    • 2023
  • Staphylococcus aureus integrated with mecA gene, which codes for penicillin-binding protein 2a, is resistant to all penicillins and other beta-lactam antibiotics, resulting in poor treatment expectations in skin and soft tissue infections. The development of a simple, sensitive and portable biosensor for mecA gene analysis in S. aureus is urgently needed. Herein, we propose a dual-toehold-probe (sensing probe)-mediated exonuclease-III (Exo-III)-assisted signal recycling for portable detection of the mecA gene in S. aureus. When the target mecA gene is present, it hybridizes with the sensing probe, initiating Exo III-assisted dual signal recycles, which in turn release numerous "3" sequences. The released "3" sequences initiate catalytic hairpin amplification, resulting in the fixation of a sucrase-labeled H2 probe on the surface of magnetic beads (MBs). After magnet-based enrichment of an MB-H1-H2-sucrase complex and removal of a liquid supernatant containing free sucrase, the complex is then used to catalyze sucrose to glucose, which can be quantitatively detected by a personal glucose meter. With a limit of detection of 4.36 fM for mecA gene, the developed strategy exhibits high sensitivity. In addition, good selectivity and anti-interference capability were also attained with this method, making it promising for antibiotic tolerance analysis at the point-of-care.

Concentration of Sodium Chloride Solutions Sensing by Using a Near-Field Microwave Microprobe (비접촉 근접장 마이크로파 현미경을 이용한 NaCl 용액의 농도 측정)

  • Kim, Song-Hui;Yoon, Young-Woon;Babajanyan, Arsen;Kim, Jong-Chul;Lee, Kie-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.23-30
    • /
    • 2007
  • We observed the NaCl concentration of solutions using a near-field microwave microprobe(NFMM). Instead of the usual technique, we take advantage of the noncontact evaluation capabilities of a NFMM. A NFMM with a high Q dielectric resonator allows observation of small variations of the permittivity due to changes in the NaCl concentration. The changes of NaCl concentration due to a change of permittivity of the NaCl solution were investigated by measuring the microwave reflection coefficient $S_{11}$ of the resonator. The NaCl sensor consisted of a dielectric resonator coupled to a probe tip at an operating frequency of about f=4 GHz. The change of the NaCl concentration is directly related to the change of the reflection coefficient due to a near field electromagnetic interaction between the probe tip and the NaCl solution. In order to determine the probe selectivity, we measured a mixture solution of NaCl and glucose.

Anti-lymphoma Activities of Phlojodicarpus sibiricus and Artemisia kruhsiana Besser Extracts (Phlojodicarpus sibiricus와 Artemisia kruhsiana Besser 추출물의 항림프종 효과 분석)

  • Kim, Jisu;Kim, Dong Uk;Nam, Jehyun;Jeon, Byeol Eun;Okhlopkova, Zhanna M.;Zulfugarov, Ismayil S.;Kim, Sang-Woo
    • Journal of Life Science
    • /
    • v.30 no.4
    • /
    • pp.379-385
    • /
    • 2020
  • Phlojodicarpus sibiricus and Artemisia kruhsiana Besser are medicinal plants traditionally used in Russia. Phlojodicarpus sibiricus extracts (PSE) have been shown to have anti-obesity properties, and Artemisia kruhsiana Besser extracts (AKBE) contain terpenoid compounds that exert various medicinal effects. Here, we investigated the potential pro-apoptotic effects of PSE and AKBE in diffuse large B-cell lymphoma (DLBCL) and elucidated the underlying mechanism. PSE and AKBE treatment of six DLBCL cell lines with various genetic abnormalities effectively reduced cell viability in a dose-dependent manner, while having a minimal impact on the survival of normal murine bone marrow cells and splenocytes. This suggests that the cytotoxic effects of PSE and AKBE are specific to DLBCL cells. Therefore, we expect limited side effects when these plant extracts are administered to DLBCL patients. Our JC-1 assays demonstrate that the pro-apoptotic effects of these plant extracts are produced by a reduction of anti-apoptotic Bcl-2 family members and, thereby, disruption of the mitochondrial membrane potential. Moreover, PSE and AKBE induce cell death independently of Myc, whose abnormalities are frequently observed in patients with DLBCL and are associated with poor prognosis. Our findings reveal hitherto uncharacterized pro-apoptotic effects of PSE and AKBE in DLBCL. Isolation of single compounds with anti-lymphoma activities should be pursued further.