• Title/Summary/Keyword: Integrated Control Center

Search Result 428, Processing Time 0.028 seconds

A Study on the Policy Advice of Integrated CCTV Control Center

  • Chung, ChoongSik
    • International Journal of Advanced Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.46-55
    • /
    • 2017
  • In recent years, public area CCTV has also begun to become more popular in the Korea. 2011, Korea's Ministry of Public Administration and Security has recommended that other local governments set up an integrated CCTV control center in each of their districts. The ministry was planning to make it compulsory for local governments to install an integrated CCTV control center by 2015. More than 570,000 public cameras are managed by public agencies and local government offices. Currently, the integrated CCTV control center is playing a very positive role in fighting crimes in the district particularly through its liaison with the district police. The CCTVs were operated by a several different agencies and departments in the district, resulting in considerable redundancy in public service, inefficiency and delays in response to crimes, and other emergency situations. Therefore, Control Center should be operated lawfully and efficiently. CCTV Control Center will be managed by three ways: (1) IT Governance through cooperation with civil areas (2) by regulated with proper laws and (3) managed by proper guideline and personal training.

Integrated Control Center on the drawing board for the Northeast Asia Region Interconnected Power System (동북아 연합급전소 구상)

  • Yoon, Kap-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.20-23
    • /
    • 2005
  • This paper introduces the latest discussions on the Integrated Dispatch Center (IDC, or Integrated Control Center: ICC) for the Northeast Asia Region Interconnected Power System (NEAR-IPS). The IDC is for the safety and economical operation of the NEAR-IPS. The status and plans of the EPSs and the control systems (or dispatch centers) to be interconnected shall be reviewed and the consideration on the IDC to be built in the future shall be discussed.

  • PDF

Performance Characteristic of the β-Human Chorionic Gonadotropin Assay on the Access 2 for Its Use in Doping Control

  • Kang, Min-Jung;Lee, Hye-Im;Shin, Sang-Mi;Yoo, Hye-Hyun;Kwon, Oh-Seung;Jin, Chang-Bae;Chung, Bong-Chul
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2889-2892
    • /
    • 2010
  • The objective of this study was to validate performance characteristics of the Access 2 (Beckman coulter) system for hCG assays for use as a confirmation test for doping control. The Access 2 assay was linear up to 500 IU/L. The correlation coefficient was higher than 0.999, and the sensitivity of the linearity was 0.82. There were no false positive or false negative cases. LOD was 0.59 IU/L. The method was robust when performed by different people. Repeatability and reproducibility were below 7%. We compared reproducibility and recoveries of Access 2 and Elecsys 2010. Access 2 demonstrated higher reproducibility than Elecsys 2010. Recoveries (accuracy) of Access 2 were between 85 and 105%. Recoveries for Elecsys 2010 were between 91 and 104%.

A case study on the building of integrated CCTV control center at Busan metropolitan city (부산광역시 CCTV통합관제센터구축 사례연구)

  • Kwon, Chang-Hwan;Seo, Chang-Gab
    • Journal of Digital Convergence
    • /
    • v.9 no.3
    • /
    • pp.191-202
    • /
    • 2011
  • Public agencies and local governments have been installing CCTV cameras for the prevention of crime, traffic jam, and unauthorized waste. Additionally, national government agencies and schools, a special corporation by special law, local construction and industrial company installed CCTV cameras of their own and are operating them. Various types of CCTV systems disclosed technical heterogeneity. In February, 2011, Ministry of Public Administration and Security presented guidelines for building an integrated control center. This study examines the case of Busan by using the administrative guidelines. Busan integrated CCTV control center among themselves, police agency and fire department. This study looks into the potential problems with the integration process of CCTV cameras and proposes a solution to them.

Integrated Voltage/Var control based on Distributed Load Modeling with Distributed Generation in Distribution System (분산전원이 설치 된 배전 계통의 분포부하를 이용한 IVVC알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choe, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.95_96
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load with Distributed Generation and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

  • PDF

Identification of DNA Aptamers toward Epithelial Cell Adhesion Molecule via Cell-SELEX

  • Kim, Ji Won;Kim, Eun Young;Kim, Sun Young;Byun, Sang Kyung;Lee, Dasom;Oh, Kyoung-Jin;Kim, Won Kon;Han, Baek Soo;Chi, Seung-Wook;Lee, Sang Chul;Bae, Kwang-Hee
    • Molecules and Cells
    • /
    • v.37 no.10
    • /
    • pp.742-746
    • /
    • 2014
  • The epithelial cell adhesion molecule (EpCAM, also known as CD326) is a transmembrane glycoprotein that is specifically detected in most adenocarcinomas and cancer stem cells. In this study, we performed a Cell systematic evolution of ligands by exponential enrichment (SELEX) experiment to isolate the aptamers against EpCAM. After seven round of Cell SELEX, we identified several aptamer candidates. Among the selected aptamers, EP166 specifically binds to cells expressing EpCAM with an equilibrium dissociation constant (Kd) in a micromolar range. On the other hand, it did not bind to negative control cells. Moreover, EP166 binds to J1ES cells, a mouse embryonic stem cell line. Therefore, the isolated aptamers against EpCAM could be used as a stem cell marker or in other applications in both stem cell and cancer studies.

Development of a Joint Torque Sensor Fully Integrated with an Actuator

  • Kim, Bong-Seok;Yun, Seung-Kook;Kang, Sung-Chul;Hwang, Chang-Soon;Kim, Mun-Sang;Song, Jae-Bok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1679-1683
    • /
    • 2005
  • This paper suggests the new type of a joint torque sensor which is attached at each joint of a manipulator for making compliance. Previous six axis force/torque sensors are high cost and installed end-effector of the manipulator. However, torque on links of previous an end-effector cannot be measured. We design a joint torque sensor that can be fully integrated with an actuator in order to measure applying torque of the manipulator. The sensor system is designed through the structural analysis. The proposed joint torque sensors are installed to the 6 DOF manipulator of a mobile robot for hazardous works and we implemented experiments of measuring applied torque to the manipulator. By the experiment, we proved that the proposed low-cost joint torque sensor gives acceptable performance when we control a manipulator.

  • PDF

Practical Methodology of the Integrated Design and Power Control Unit for SHEV with Multiple Power Sources

  • Lee, Seongjun;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.353-360
    • /
    • 2016
  • Series hybrid electric vehicles (SHEVs) having multiple power sources such as an engine- generator (EnGen), a battery, and an ultra-capacitor require a power control unit with high power density and reliable control operation. However, manufacturing using separate individual power converters has the disadvantage of low power density and requires a large number of power and signal cable wires. It is also difficult to implement the optimal power distribution and fault management algorithm because of the communication delay between the units. In order to address these concerns, this approach presents a design methodology and a power control algorithm of an integrated power converter for the SHEVs powered by multiple power sources. In this work, the design methodology of the integrated power control unit (IPCU) is firstly elaborately described, and then efficient and reliable power distribution algorithms are proposed. The design works are verified with product-level and vehicle-level performance experiments on a 10-ton SHEV.

Study on Implementation Scheme for Integrated PSD Control System of Seoul Metro (서울메트로 PSD 통합관제시스템 구축방안에 대한 연구)

  • Kim, Yong-Hyeop;Hyun, Yong-Sub;Ryoo, Ho-Joong;Kim, Jin-Su
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1551-1559
    • /
    • 2007
  • Seoul Metro has been constructing the screen doors on the platforms to provide safe and comfort environments. The screen doors of each station are configured so that they can be operated in automatic mode in connection with ATC/ATO through the integrated control panel in the station control room and in manual mode through the control panel of the station control room and crew control panel. These systems have been implemented with different data communication protocols between systems, HMI configuration, and so on due to ordering processes, implementation time and diverse suppliers, and manufactured to be operated within single station. Seoul Metro has been planning to implement the integrated control system to secure seamless train operation and safety and to have a fast response system against emergency situations such as PSD failure and fire, by implementing the system that is able to collectively manage, monitor and control the operation status and equipment conditions of PSD on to the integrated control center. This paper has studied a scheme to reduce the budget for the future facility constructions by standardizing the data format for data communication with the integrated station control panel and using the open standard protocols, in order to secure consistency of operation, system expansion and maintenance with unified and standardized control items.

  • PDF

An Integrated Transformer-based LED Power Supply with Wide-Output-Voltage Control (통합변압기 적용 넓은 출력전압제어 LED 전원공급장치)

  • Kang, Cheol-Ha;Ju, Jong-Seong;Kim, Eun-Soo;Won, Jong-Seob;Lee, Young-Soo;Kim, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.437-447
    • /
    • 2015
  • In this paper, implementation of an integrated transformer applicable to power supply units (PSUs) for a 150-W LED with a wide range of output voltage is presented. The transformer is comprised of a PFC inductor and an LLC resonant transformer, each of which is placed and integrated on an E-I-E-type magnetic core. Integrated transformers with two different air gap topologies (i.e., the side and center gap topologies) are considered in the design phase to investigate their applicability. The design consideration on the LLC resonant converter used for the wide-output-voltage control ranges is described, and the overall performance of the proposed system is verified through realization of it onto a 150-W LED PSU board.