• Title/Summary/Keyword: Insulation level

Search Result 341, Processing Time 0.029 seconds

Effective Installation Methods of Down Conductors in Lightning Protection Systems (뇌보호시스템에서 인하도선의 효과적인 설치기법)

  • 이복희;엄주홍;이승칠;강성만
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.8-14
    • /
    • 2002
  • A modern lightning protection system is required to eliminate the risks such as electrical shocks and damages of structures, electrical and electronic equipments due to lightning. However, the conventional lightning protection systems play and important role in protecting persons and structures only. Thus an effective lightning protection system is indispensable today in computer, information and communication facilities and etc. The mafor objective of this paper is to develop the technology to protect electronics and computerized facilities against lightning-caused overvoltages. The study is oriented on the control of the potential rise of down conductors with the type and installation method of down conductors. As a result, to reduce side flashes and hazards caused by the potential rise of down conductor due to lightning current, the coaxial cable with a low characteristic impedance and high insulation level is suitable for a down conductor. In particular it is extremely effective to bond down conductors to the steel supporter, metal raceways and steel frame of structures.

An Empirical Study on Air Force Mechanic Parka to Improve the Functionality (공군 정비파카의 기능성 개선을 위한 실태조사)

  • Lee, Sung-Ji;Nam, Yun-Ja;Choi, Hee-Eun;Cho, Young-Lim
    • Fashion & Textile Research Journal
    • /
    • v.13 no.5
    • /
    • pp.759-768
    • /
    • 2011
  • This study is designed to understand current wearing conditions of air force mechanic parkas and evaluate their functionality by examining the wearing conditions and wearers' subjective assessment. By doing so, it also intends to identify issues that require improvements; and to provide basic data for future development of air force mechanic parkas. A survey was conducted as a study methodology, and the collected 1,628 questionnaires were analyzed. Findings of this study are as follows. 1. In the usability assessment, it was found that visibility of body sides was needed to be enhanced since reflective tapes were attached only to the front and back of the body; pockets were too big, but not convenient to keep mechanic tools; the design of hiding hood was not suitable for water-proof clothing; and a new design of size-controllable hood was called for since the hood blocked eye sight. With respect to the fabric, dissatisfaction was identified with durability, cold-proof and fire-proof features. 2. In the mobility assessment, respondents showed low satisfaction with collar heights and neck girths. Mobility score was over moderate level on average, except the parka length that obstructs wearers' movement, and neck and collar size. 3. In the wearability assessment, respondents presented moderate satisfaction with pleasantness, weight, pressure and dampness. However, insulation was found unsatisfactory. Based on the result, this study proposed improvement plans on design, pattern and fabric; and is expected to serve as basic data for developing more effective and functional air force mechanic parkas.

A Study on the Short-Term Plan of Structural Reinforcing and the Temporary Housing Supply Strategy through the Analysis of the Status of North Korean Standard Housing

  • Kim, Seong Eun;Kim, Seung Hun;Lee, Yong Taeg
    • Architectural research
    • /
    • v.20 no.3
    • /
    • pp.83-92
    • /
    • 2018
  • Recently, there has been inter-Korean exchanges are active, in company with an assertive international activity with North Korea and inter-Korean Summits. Thus, there is a growing possibility of Korean reunification. However, when the unification situation occurs, population inflow by North Korean residents will be expected, and it will be necessary to prepare a housing supply strategy. In addition, even if North Koreans are prevented from entering, a plan is necessary to ensure structural safety since most buildings in North Korea are aging and a recent natural disaster occurs frequently. In this research, we will try to present a temporary housing supply strategy and a short-term structural reinforcement plan based on analysis of the standard housing conditions in North Korea. In this research, we represent the analysis result of the existing construction level, supply status and structural performance of North Korea. When we consider the reinforcement period and social costs, a short-term reinforcement plan is recommended rather than the full reinforcement of the aged housing in North Korea. Furthermore, we examine the ways to secure the residential safety of North Koreans through a case study of domestic and overseas temporary residential facilities, until the permanent residential facilities were supplied. According to the analysis, the tent houses were used as a form of relief housing in overseas frequently. However, the tent house is difficult to apply for domestic country with clear seasons due to insulation and heating problems. Therefore, it is appropriate to develop a residential supply strategy as focusing on the temporary housing facilities in assembled or container from, in preparation for the future population inflow.

Characteristics of superconducting fault current limiters with various pattern shape (초전도 전류제한기의 패턴형상별 특성)

  • Choi, H.S.;Chung, H.S.;Choi, C.J.;Lee, S.I.;Chung, S.B.;Oh, G.K.;Lim, S.H.;Han, B.S.;Chung, D.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.529-532
    • /
    • 2003
  • Quench behavior of resistive superconducting fault current limiters (SFCLs) with various pattern shapes was investigated. The pattern shapes employed were meander, bi-spiral, and spiral shapes of identical line width, gap and margin. SFCLs were fabricated from YBCO thin films grown on two-inch diameter $Al_2O_3$ substrates under the same conditions. Resistance rise of current limiting elements was low at a spiral shape before the whole quench completion, which may act as a disadvantage for simultaneous quench in serial connection between current limiting elements, but the temperature tended to have similar values at higher voltages. On the other hand, bi-spiral shape was severe at insulation level between current limiting lines. When these aspects were considered, we concluded that a meander shape was appropriate to design for a resistive SFCL based on thin films except the concentration of electric field at edge areas of strip lines.

  • PDF

A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes - (필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 -)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.48-54
    • /
    • 2016
  • Pilotis are support columns that lift a building above the ground. Thus, they can elevate the lowest floor to the secondfloor level and, in Korea, are used to leav a parking area below multifamily housing. However, if there is a fire in the piloti area, the cars and main entrance door are wrapped in flames. Due to the inflammability of the materials, the combustion of the cars and insulation at the ceiling of the pilotis, having a high heat release rate, can quickly destroy the front entrance of the building and spread heat, flames and a poisonous gas to the stairs and elevator pit. Therefore, the fire can quickly spread to the whole building, putting the lives of the residents in danger. This study was an in-depth accidental case study of the "Uijeongbu Fire Accident" that killed 5 residents and injured 139 others. The study identified the relationships between the fire at the piloti structure of multifamily housing and the vulnerability of this structure and its inherent weaknesses.

Numerical Study on Two-phase Natural Circulation Flow by External Reactor Vessel Cooling of iPOWER (혁신형 안전경수로의 원자로용기 외벽냉각 시 2상 자연순환 유동에 대한 수치해석적 연구)

  • Park, Yeon-Ha;Hwang, Do Hyun;Lee, Yeon-Gun
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.103-110
    • /
    • 2019
  • The domestic innovative power reactor named iPOWER will employ the passive molten corium cooling system(PMCCS) to cool down and stabilize the core melt in the severe accident. The final design concept of the PMCCS is yet to be determined, but the in-vessel retention through external reactor vessel cooling has been also considered as a viable strategy to cope with the severe accident. In this study, the two-phase natural circulation flow established between the reactor vessel and the insulation was simulated using a thermal-hydraulic system code, MARS-KS. The flow path of cooling water was modeled with one-dimensional nodes, and the boundary condition of the heat load from the molten core was defined to estimate the naturally-driven flow rate. The evolution of major thermal-hydraulic parameters were also evaluated, including the temperature and the level of cooling water, the void fraction around the lower head of the reactor vessel, and the heat transfer mode on its external surface.

Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP (EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.82-93
    • /
    • 2006
  • In this paper, filters are designed to reduce transients overvoltage in inverter fed high-voltage large-capacity induction motor drive system. Design issues for a LCR filter at the inverter output terminals to reduce the dv/dt of the inverter output pulse and a RC filter at the induction motor input terminals to match the characteristic impedance between cable and induction motor are examined in detail. These filters are modeled to be suitable to high-voltage large-capacity induction motor. The performance of the filter is evaluated through simulation using EMTP(ElectroMagnetic Transients Program). We presented filters that used high voltage large-capacity induction Motor on the basis of this. Effect of the filter is analyzed for variation of the cable length. Characteristics of filters are analyzed to reduce harmonic in voltage waveform of induction motor input terminal. The switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. Filter for to mitigate transients overvoltage presents a required component in drive system of high-voltage large-capacity induction motor. Also, proposed filters are proved through simulation using EMTP.

Determination of Proto Type for 345kV CV Cable Accessories (345kV CV 케이블 접속함의 Proto Type 선정)

  • Lee, S.K.;Kim, I.T.;Son, S.H.;Choi, S.G.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1629-1631
    • /
    • 1998
  • Crosslinked polyethylene (XLPE) insulated cables are now widely used all over the world for extra-high voltage underground transmission systems. Prefabricated type (compression type) joint has developed in order to shorten the assembly time and lower the possibility of contamination at site by many companies in the world. For outdoor termination, to control the electric field distribution as uniform as possible, especially for the use of extra-high voltage system. much of products are adopting the oil-impregnated condensor cone type instead of electric field control element which uses the permitivity of it only (not capacitance). For Gas-immersed termination, dimension of outer insulation bushing was determined by IEC Publication 859. The highest voltage of underground power cable system is 345kV now, in Korea. We have much of experiences of the development of prefabricated type accessories for CV cable systems (154kV, 161kV, 230kV level). So it was possible to inspect the proto type of accessories for 345kV CV cable system and seems that the need time for the development of products is reduced.

  • PDF

A Study on the Reliability Prediction about ECM of Packaging Substrate PCB by Using Accelerated Life Test (가속수명시험을 이용한 Packaging Substrate PCB의 ECM에 대한 신뢰성 예측에 관한 연구)

  • Kang, Dae-Joong;Lee, Hwa-Ki
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.109-120
    • /
    • 2013
  • As information-oriented industry has been developed and electronic devices has come to be smaller, lighter, multifunctional, and high speed, the components used to the devices need to be much high density and should have find pattern due to high integration. Also, diverse reliability problems happen as user environment is getting harsher. For this reasons, establishing and securing products and components reliability comes to key factor in company's competitiveness. It makes accelerated test important to check product reliability in fast way. Out of fine pattern failure modes, failure of Electrochemical Migration(ECM) is kind of degradation of insulation resistance by electro-chemical reaction, which it comes to be accelerated by biased voltage in high temperature and high humidity environment. In this thesis, the accelerated life test for failure caused by ECM on fine pattern substrate, $20/20{\mu}m$ pattern width/space applied by Semi Additive Process, was performed, and through this test, the investigation of failure mechanism and the life-time prediction evaluation under actual user environment was implemented. The result of accelerated test has been compared and estimated with life distribution and life stress relatively by using Minitab software and its acceleration rate was also tested. Through estimated weibull distribution, B10 life has been estimated under 95% confidence level of failure data happened in each test conditions. And the life in actual usage environment has been predicted by using generalized Eyring model considering temperature and humidity by developing Arrhenius reaction rate theory, and acceleration factors by test conditions have been calculated.

Study on the Thermal Protective Performance Measurements of Fire Fighter's Protective Clothing for Low Level Radiant Heat Exposures (저열유속 조건의 복사열 노출에 따른 소방보호복의 열보호성능 측정에 관한 연구)

  • Lee, Jun-Kyoung;Bang, Young-Jun;Bang, Chang-Hoon;Kwon, Jung-Suk
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.1-8
    • /
    • 2014
  • Despite advancements in the development of synthetic fibers and materials that provide better insulation, fire burn injuries remain a significant issue. To ensure adequate protection, clothing and equipment must be selected on the basis of performance. There are different standards like ISO standards applicable to each of the various types of clothing used by fire fighters. But, in most cases, the tests are performed in the conditions of high heat flux exposure, the clothing material can be destroyed easily. Thus the effective way to investigate the protective performance for the low (radiant) heat flux conditions should be needed. Therefore improved RPP (Radiant Protective Performance) test method based on the onset of pain burn injury was suggested. Experiments were performed to verify the proposed method with current protective clothing for fire fighters and the transient heat transfer characteristics were identified, also. Moreover, several protective performance indices were acquired from experimental results to analyze their relations.