• 제목/요약/키워드: Insulation characteristics

검색결과 1,267건 처리시간 0.026초

SF6 가스 중 직류 고전압 하에서 부분방전 특성 (Characteristics of Partial Discharge Under HVDC in SF6 Gas)

  • 김민수;김선재;정기우;조향은;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제27권4호
    • /
    • pp.238-243
    • /
    • 2014
  • This paper dealt with the measurement and analysis of partial discharge (PD) under high voltage direct current (HVDC) in SF6 gas. Electrode systems such as a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack on epoxy plate and a free particle (FP) were fabricated to simulate the insulation defects. The analysis system was designed with a Time-Frequency (T-F) map algorithm programed based on LabVIEW. This can arrange the acquired PD pulses into frequency and time domain. A HVDC power source is composed of a transformer (220 V/50 kV), a diode (100 kV) and a capacitor (50 kV, 0.5 ${\mu}F$). The gap between the electrodes is 3 mm, and the $SF_6$ gas was set at 5 bar. PD pulses were detected by a 50 ${\Omega}$ non-inductive resistor. In the analysis, PD pulses were distributed below 0.5 MHz and 20 ns ~ 35 ns for the POC, 0.7 MHz ~ 1.7 MHz, below 0.6 MHz and 10 ns ~ 40 ns and 60 ns ~125 ns for the POE, below 0.1 MHz and 135 ns ~ 215 ns for the crack, and below 1.6 MHz and 250 ns for the FP.

부분방전 패턴인식을 위해 EMC센서를 이용한 최적화된 RBFNNs 분류기 설계 (Design of Optimized Radial Basis Function Neural Networks Classifier Using EMC Sensor for Partial Discharge Pattern Recognition)

  • 정병진;이승철;오성권
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1392-1401
    • /
    • 2017
  • In this study, the design methodology of pattern classification is introduced for avoiding faults through partial discharge occurring in the power facilities and local sites. In order to classify some partial discharge types according to the characteristics of each feature, the model is constructed by using the Radial Basis Function Neural Networks(RBFNNs) and Particle Swarm Optimization(PSO). In the input layer of the RBFNNs, the feature vector is searched and the dimension is reduced through Principal Component Analysis(PCA) and PSO. In the hidden layer, the fuzzy coefficients of the fuzzy clustering method(FCM) are tuned using PSO. Raw datasets for partial discharge are obtained through the Motor Insulation Monitoring System(MIMS) instrument using an Epoxy Mica Coupling(EMC) sensor. The preprocessed datasets for partial discharge are acquired through the Phase Resolved Partial Discharge Analysis(PRPDA) preprocessing algorithm to obtain partial discharge types such as void, corona, surface, and slot discharges. Also, when the amplitude size is considered as two types of both the maximum value and the average value in the process for extracting the preprocessed datasets, two different kinds of feature datasets are produced. In this study, the classification ratio between the proposed RBFNNs model and other classifiers is shown by using the two different kinds of feature datasets, and also we demonstrate the proposed model shows superiority from the viewpoint of classification performance.

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

이축 연신된 폴리프로필렌 필름의 전하주입 현상이 절연특성에 미치는 영향 (Influence of the Insulating Properties on Charge Injection Phenomena of Biaxially-Drawn Polypropylene Film)

  • 이준웅;김병태;박승협
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제1권2호
    • /
    • pp.74-81
    • /
    • 1987
  • 고분자 절연재료에 전하주입시 발생하는 캐리어 트랩현상은 재료의 절연성을 저하시키는데 중요한 영향을 미치는 것으로 알려져 있다. 따라서 본 연구에서는 절연재료의 전기적 특성을 개선한다는 측면에서 캐리어의 거동을 파악하기 위해 내열성이 폴리프로필렌보다 우수한 이축 연신된 폴리프로필렌 필름(두께 $50\mu\textrm{m}$)을 선정하여 전계변화에 따른 열자격전류 스펙트라를 분석 검토하였다. 온도범위 303~413[K]와 전계범위 2~80[㎹/m]에서 열자격 전류의 변화를 살펴본 결과 전계 12[㎹/m]이하에서는 전하주입의 효과가 관찰되지 않았으나 전계가 점점 높아지면 트랩된 공간전하와 전극으로부터 주입된 공간전하가 형성되어 Hetero 및 Homo성 열자격전류 스펙트라가 나타나며 이는 결국 절연파괴를 야기시키는 것으로 예측되어진다. 또한 이축 연신된 시료가 미연신 재료보다 우수한 절연특성을 가지고 있음을 확인 할 수 있었다.

  • PDF

일반벽체와 교호 샛기둥 벽체의 역학적 성능 비교 연구 (A Study on The Comparison of Mechanical Property Between The Staggered Stud Wood Wall and The Standard Wood Frame Wall)

  • 심재광;김광철
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권5호
    • /
    • pp.640-649
    • /
    • 2017
  • 목조건축의 기반을 넓히고 소비자의 만족도를 향상시키기 위해 기존의 일반목조벽체 및 기타 경량목조벽체에 대한 비교 연구가 필요하다. 따라서 본 연구에서는 일반벽체와 개선된 방식인 교호 샛기둥 벽체와의 성능 비교를 통해 새로운 가능성을 찾고자 하였다. 우선 교호 샛기둥 벽체의 강도적 특성을 평가하고 일반벽체의 강도적 특성을 비교하였다. 일반벽체를 구성하는 목재의 단면이 교호 샛기둥 벽체보다 크기 때문에 일반벽체의 최대하중이 교호 샛기둥 벽체 보다 크게 나타났다. 하지만, 두 그룹간의 통계분석에 의하면 95% 신뢰 수준에서 유의성을 보이지 않아, 교호 샛기둥 벽체는 일반벽체를 대체할 수 있는 가능성을 보여주었다. 교호 샛기둥 벽채는 샛기둥의 단면이 일반벽체보다 작기 때문에 재료를 절약할 수 있어서 일반벽체보다 더 경제적이라고 판단된다. 또한 단열재의 면적 또한 증가하므로 열교 현상의 개선도 기대된다.

실내 먼지 중 브롬화난연제 함유특성 연구 (Contents characteristics of polybrominated diphenyl ethers (PBDEs) in indoor household dust)

  • 김교근
    • 분석과학
    • /
    • 제26권2호
    • /
    • pp.113-119
    • /
    • 2013
  • 본 연구에서는 전기전자제품에 브롬화난연제로 널리 사용되고 있는 폴리브롬화디페닐에테르가 우리의 생활에서 어떻게 배출되는지 파악하고자 가정에서 발생되는 먼지 시료를 2011년 1월부터 12월까지 채취 분석하여 이성체 함량특성을 조사하였다. 아파트와 실험실에서 채취한 실내 먼지 중 총 22종의 PBDEs (47, 49, 66, 71, 77, 85, 99, 100, 119, 126, 138, 153, 154, 156, 183, 184, 191, 196, 197, 206, 207, 209)를 분석하여 정량한 결과, 아파트 실내 먼지에서 검출된 PBDEs 농도는 35.22~575.88 ng/g으로 나타났으며, 실험실에서 겨울에 채취된 먼지 중에서는 PBDEs가 524.44 ng/g 검출되었다. 분석시료 중 1ng/g 이상 검출된 이성체는 BDE-47, 153, 183, 196, 197, 206, 207, 209 등 8종으로 조사되었으며, 모든 시료에서는 BDE-206, 207, 209 3종의 이성체가 검출되었다.

전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석 (Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact)

  • 김두현;황동규
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

동파방지열선 화재 흔적분석과 발화원인 연구 (A Study for the Fire Analysis and Igniting Cause of Freezing Protection Heating Cables)

  • 이정일;하각천
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.15-20
    • /
    • 2018
  • There have been a number of major fatal fire accidents in Korea recently. The number of fires in 2017 were 44,178, which is not only increasing number of fires but also increasing in casualties. Particularly, the fire at Jecheon Sports Center, which suffered many casualties, is expected to have a huge impact. The cause of the fire has not been determined yet, but heat waves on the ceiling have also been pointed out. As such, the copper heating waves, which are used as a preventive measure against damage of pipes due to freezing of pipes, etc., always have a fire hazard. To determine the possibility of a flame-resistant heated fire, a positive electric cable product was used to artificially ignite and analyze the results. In case of a short circuit, the external covering of the positive electric cable is damaged, but not short circuit unless the heating material surrounding the wire is damaged. Due to the characteristics of heating cable for preventing copper waves, the chances of insulation becoming more severe due to moisture and temperature changes are higher than normal wires. If the internal heating system is carbonized by insulating deterioration without damage to the outer coating, it is likely to cause trekking, to form a winding loop in the heating materials, and to cause short circuit in the heated materials. For the positive temperature line, if the middle is shorted, the current continues to flow to the short circuit unless the breaker disconnects. Consequently, a heated fire that does not cut off the power immediately may leave multiple marks or cuts.

노인의 의.식.주생활 및 심리적 적응을 위한 이상적 모델개발 연구 -양로원을 중심으로- (The Development of a Retirement Home Model with Emphasis on Clothing, Nutrition, Housing, and Psychological Dimension)

  • 윤복자
    • 대한가정학회지
    • /
    • 제27권4호
    • /
    • pp.167-191
    • /
    • 1989
  • The present study was conducted to devlop and appropriate retirement home model for the elderly in terms of clothing and textiles; nutrition, health, and foodservice; housing and environment; and psychological adaptation. Specifically, the purposes of the study were: 1) to provide basic guidelines for clothing by comparing the clothing behavior of the elderly living in the retirement home and those living in their own homes with family, 2) to provide basic guidelines for balanced diet and effective foodservice, 3) to develop an ideal life space and facilities, and 4) to assess the psychological characteristics of the elderly. Questionnaires, observation, experimental method, and survey of literature were used for the study. Clothing behavior showed that the elderly were much concerned about clothing, and they preferred comfortable as well as fashionable designs. The elderly in the retirement homes complained of a lack of quantity and variety in clothing. They preferred natural fiber rather than blended fabrics. Flame resistance, thermal insulation, and flexibility of textile fabrics were found to be prime considerations in manufacturing and selecting clothing materials for the elderly. The health status of the surveyed elderly was generally good, but some poor eating habits were observed. Dietary nutrients intakes were generally sufficient, but several nutrients intakes were insufficient. The level of equipment in the kitchens of the institutions was low. Furthermore, the employment rate of dietitians in institutional settings was extremely low. This resulted in a lack of systematic foodservice management. Residents in the institution were generally satisfied with present life space and facilities but this was mainly because of abandonment, adaptation, and past experience. Optimal allocation of residents per bedroom and an adequate design for storage, bathroom, utility room, and dining room were recommended. The comparison of psychological status of the elderly living at home was more stable than those living in an institution. The emotional state of the elderly living in the institution was characterized by loneliness; they did not have close interpersonal relationships or future plans. An appropriate model for the elderly was developed on the basis of these findings.

  • PDF

펄스형 고전압 측정용 용량성 분압기 (Capacitive Voltage Divide for a Pulsed High-Voltage Measurement)

  • 장성덕;손윤규;권세진;오종석;조무현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.63-68
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source are under operation for 2.5 GeV electron linear accelerator in Pohang Light Source (PLS) linac. The klystron-modulator system has an important role for the stable operation to improve an availability statistics of overall system performance of klystron-modulator system. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are demanded for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider (CVD), which divides input voltage as capacitance ratio, is intended for the measurement of a beam voltage of 400 kV generated from the klystron-modulator system. Main parameter to determine standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will be present and discuss the design concept and analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance effects and oil temperature variation.