• Title/Summary/Keyword: Insulation characteristics

Search Result 1,269, Processing Time 0.215 seconds

Multiple accelerated degradation test and failure analysis for $Ni-BaTiO_3$ MLCCs ($Ni-BaTiO_3$ MLCCs에 대한 복합 가속 열화 시험 및 고장 분석)

  • Kim, Jung-Woo;Kim, Jin-Seong;Lee, Hee-Soo;Kang, Do-Won;Kim, Jeong-Wook
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.2
    • /
    • pp.102-105
    • /
    • 2009
  • The accelerated life time test of the MLCCs with different $BaTiO_3$ particle sizes were conducted at $150^{\circ}C$, 75 V condition and the effect of $BaTiO_3$ particle size on the breakdown voltage and degradation characteristics of MLCCs was investigated. The MLCCs were prepared by using the $BaTiO_3$ particles having the size of $0.525{\mu}m$, $0.555{\mu}m$, $0.580{\mu}m$ and Ni-electrode, respectively. The MLCCs which have the particle size of $0.525{\mu}m$, $0.555{\mu}m$, and $0.580{\mu}m$, respectively were confirmed to meet the standard requirements of X5R(change capacitance within ${\pm}15%$ at $-55{\sim}85^{\circ}C$) by TCC(Temperature Coefficient of Capacitance). The effect of the $BaTiO_3$ particle size on the insulation resistance behavior of MLCCs was confirmed by BDV(Breakdown Voltage) measurements and the cause and degree of degradation of MLCCs were characterized by XPS analysis after the accelerated life test. The MLCCs with $0.525{\mu}m-BaTiO_3$ showed better insulation resistance and BDV characteristics compare to other MLCCs and XPS analysis revealed that the MLCCs degradation is caused by the NiO peak and $BaTiO_3$ peak decrease.

Analysis of Heat Transfer Characteristics by Materials in Closed Conditions Using Acrylic Hemisphere (I): Comparison of Interior Finishing Materials (아크릴 반구를 이용한 밀폐 조건에 따른 재료별 열 이동 특성 분석(I): 실내마감재 종류에 따른 비교)

  • YANG, Seung Min;LEE, Hyun Jae;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.217-230
    • /
    • 2020
  • Global warming has increased interest in reducing greenhouse gas emissions. And a policy has effort to reduce energy consumption as a greenhouse gas reduction plan. In Korea, 25% of total energy is consumed in the building sector. In order to reduce energy consumption of buildings, it is possible to expand the utilization of wood as a structural material or thermal insulation materials with low thermal conductivity. It is also reported that when used as an interior finishing material, the energy consumption of the building is reduced by up to 7% by insulation performance. In this study, the heat transfer characteristics and the heat capacity were compared according to the three type of finishing materials(cement, paulownia coreana, medium density fiberboard) normally used as indoor finish materials. Through this study, most of the heat transfer volumes are transferred in the form of radiant heat, and the result was derived from the highest amount of energy and heat transfer in the use of paulownia coreana. When indoor finishing materials are used as wood, it is deemed that energy efficiency inside the building will be improved.

A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS (PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.121-127
    • /
    • 2016
  • This study analyzed the structural and electrical characteristics of an iron fittings type Corrugated Stainless Steel Tubing (CSST) damaged by the Primary Current Injection Test System (PCITS). CSST consists of cladding, tube, nuts, clamp ring, flare cap, socket, and ball valve. For an evaluation of the dielectric withstand voltage, the area between the live part and non-live part of the CCST shall withstand a voltage of 220 V AC for one minute. For an evaluation of the insulation performance by 500 V DC, it is required that the insulation exceed more than $1M{\Omega}$ before the temperature rise test, $0.3M{\Omega}$ after the test. Although the average resistance of the product was $11.5m{\Omega}$, that of the product damaged at a current of 130 A by the PCITS was $11.50m{\Omega}$. Furthermore, parts of the cladding were melted and black smoke appeared when a current of 130 A applied for 10 s. After 60 s, most parts were heated and turned red. At 120 s, the parts that turned red had widened. Although it did not form a normal distribution because the P value was 0.019 with a confidential interval of 95%, it revealed outstanding characteristics with an AD (Anderson-Darling) value of 0.896 and a standard deviation of 0.5573.

A Fundamental Properties of the Concrete Using Coarse Particle Cement and Mineral Admixture (굵은입자 시멘트와 광물질 혼화재를 조합 사용하는 콘크리트의 기초적 특성)

  • Han, Cheon-Goo;Jang, Duk-Bae
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.131-138
    • /
    • 2010
  • This research intends to analyze the basic characteristics of cements(hereinafter "CC") with affordable price and particle distribution effective as hydration heat face which are discharged at the outlet of smashing process of ordinary portland cement(hereinafter "OPC") manufacturing process such as fluidity, rigidity, temporary insulation temperature increase amount etc to review the potential of developing "CC" to 3 ingredients low heat cement that substitutes fly ash and blast furnace slag(hereinafter "BS"). As a result of experiment, fluidity tended to decrease with increase in CC substitution rate, and increase with increase in FA+BS substitution rate. Air amount tended to slightly decrease with increase in CC substitution rate, and decrease with increase in FA+BS substitution rate. Condensation characteristics were such that condensation time was delayed with increase in CC and FA+BS substitution rate. As for the temperature rising amount by temporary insulation, peak temperature decreased with increase in CC substitution rate and increase in FA+BS substitution rate in general, and thereafter, temperature tended to decrease slowly. Compressive strength decreased with increase in CC and FA+BS substitution rate, and as aging goes on, long term strength was equivalent to plain or higher. By and large, when FA+BS was substituted to CC, fluidity and air amount tended to decrease, but hydration heat face showed good reduction effects, suggesting possibility of development to 3 ingredients low heat cement.

  • PDF

Evaluation of floor impact sound and airborne sound insulation performance of cross laminated timber slabs and their toppings (구조용 직교 집성판 슬래브와 상부 토핑 조건에 따른 바닥충격음 및 공기전달음 평가)

  • Hyo-Jin Lee;Yeon-Su Ha;Sang-Joon Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.572-583
    • /
    • 2023
  • Demand for wood in construction is increasing worldwide. In Korea, technical reviews of high-rise Cross Laminated Timber (CLT) buildings are under way. In this paper, Floor Impact Sound Insulation Performance (FISIP) and Transmission Loss (TL) of 150 mm thick CLT floor panels made of two domestic species, Larix kaempferi and Pinus densiflora, are investigated. The CLT slabs were tested in reverberation chambers connected vertically. When comparing Single Number Quantity (SNQ) of FISIP of the bare panels, the Larix CLT is 3 dB lower in heavy-weight and 1 dB in light-weight than the Pinus CLT. However, there was no difference when concrete toppings were added to improve the performance. As the concrete toppings became thicker, the heavy-weight was reduced by 9 dB ~ 20 dB, and the light-weight by 20 dB ~ 30 dB. And the analysis of these results with area density has confirmed that the area densities are highly correlated (R2 = 0.94 ~ 0.99) to the FISIP of the CLT. The types of CLT didn't affect the TL. Comparison of theoretical TL values with measured TL values has shown that the frequency characteristics are similar but 8 dB ~ 12 dB lower in measured values. The relationship between the TL and frequency characteristics of the tested CLT slabs was derived by using the correction value.

Analysis of PD Distribution Characteristics and Comparison of Classification Methods according to Electrical Tree Source in Power Cable (전력용 케이블 시편에서 전기트리 발생원에 따른 부분방전 분포 특성 및 발생원 분류기법 비교)

  • Park, Seong-Hee;Jeong, Hae-Eun;Lim, Kee-Joe;Kang, Seong-Hwa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.57-64
    • /
    • 2007
  • One of the cause of insulation failure in power cable is well known by electrical treeing discharge. This is occurred for imposed continuous stress at cable. And this event is related to safety, reliability and maintenance. In this paper, throughout analysis of partial discharge(PD) distribution when occurring the electrical tree, is studied for the purpose of knowing of electrical treeing discharge characteristics according to defects. Own characteristic of tree will be differently processed in each defect and this reason is the first purpose of this paper. To acquire PD data, three defective tree models were made. And their own data is shown by the phase-resolved partial discharge method (PRPD). As a result of PRPD, tree discharge sources have their own characteristics. And if other defects (void, metal particle) exist internal power cable then their characteristics are shown very different. This result Is related to the time of breakdown and this is importance of cable diagnosis. And classification method of PD sources was studied in this paper. It needs select the most useful method to apply PD data classification one of the proposed method. To meet the requirement, we select methods of different type. That is, neural network(NN-BP), adaptive neuro-fuzzy inference system and PCA-LDA were applied to result. As a result of, ANFIS shows the highest rate which value is 98 %. Generally, PCA-LDA and ANFIS are better than BP. Finally, we performed classification of tree progress using ANFIS and that result is 92 %.

Effect of $Bi_2O_3$ on Dielectric Properties and Temperature Characteristics of $[BaTiO_3]_{0.9}+[BaZrO_3, SnO_2, La_2O_3, ZrO_2]_{0.1}$ ($[BaTiO_3]_{0.9}+[BaZrO_3, SnO_2, La_2O_3, ZrO_2]_{0.1}$의 Dielectric Properties 및 Temperature Characteristics에 미치는 $Bi_2O_3$의 영향)

  • 이병하;이경희;윤영호;손상철;유광수
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.5
    • /
    • pp.397-403
    • /
    • 1993
  • Widely used dielectrics, barium titanate was promising material for ceramic capacitor. It was produced by specific formulation with various dopants-La2O3, ZrO2, SnO2, CaZrO3, CaTiO3, CaSnO3, Bi2O3, and etc.-according to demanded properties of capacitor. In this study, we would examinate the study of dielectric properties and temperatuer characteristics (T.C.) with the amount of Bi2O3. The sample was prepared with [BaTiO3]10+[BaZrO3, SnO2, La2O3, ZrO2]10 and Bi2O3 varied from 1.0, 1.5, 2.0, 2.5 to 3.0wt%. After milling and mixing for 15hrs, each sample was dried and then pressed at 700kg/$\textrm{cm}^2$ into pellets. Pellets were fired at 131$0^{\circ}C$, for 3hrs in air. As the result of measurements, dielectric constant, break down voltage, and insulation resistance were increased with the amount of Bi2O3, and the resonant frequency was shifted from high frequency to low frequency range. In the case of temperature characteristics, capacitance change rate was symmetrically changed at -$25^{\circ}C$ and +85$^{\circ}C$ respectively. Therefore, it is recognized that the temperature characteristics can be moderated with doping Bi2O3 in our study.

  • PDF

V-t Characteristics and 50% Flash-over Voltage of $SF_{6}-N_{2}$ Mixtures for Lightening Impulse Voltage ($SF_{6}-N_{2}$ 혼합가스에서 뇌충격전압에 의한 50[50%] Flash over 전압 및 V-t 특성)

  • 김정달;송원표;김동의
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.1
    • /
    • pp.21-29
    • /
    • 1993
  • In this paper, we studied the 50% flashover voltage of lightening impulse which affect the most serious damages on the insulation of the electric power network system. Also its V -t characteristics and corona process phenomena of pure $SF_6, N_2, SF_6-N_2$mixtures under the circumstances of nonuniform field gap are researched. Comparing the characteristics of pure $SF_6$ with that of $SF_6, N_2$mixtures, we discussed that breakdown processes and $SF_6, N_2$ mixture's application to economics.As a results, 50% flashover voltage of $SF_6$ 50% - $N_2$ 50% for impulse voltage is higher then that of 80% of pure SF6, measured data and calculated data by equal area law are almost equal from the points of view of V-t characteristics. Therefore, it has been known that $SF_6$ 50% - $N_2$ 50% mixtures can be used as an economic constitution gas of pure $SF_6$, it is verified that corona processes from Lichtenberg figure.

  • PDF

A study on the effective fault current limiting characteristics of stacked coated conductors with stainless steel stabilizer (스테인리스 스틸 안정화재를 가진 coated conductor의 적층 유무에 따른 효과적인 사고전류 제한을 위한 연구)

  • Na, J.B.;Ahn, M.C.;Kim, M.J.;Kim, Y.J.;Yang, S.E.;Park, D.K.;Kim, H.M.;Seok, B.Y.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.9-13
    • /
    • 2007
  • Coated conductor(CC) is recently in actively progress for the research and development, and its can be used various stabilizer lot the specific requirements for each application. Among various superconducting applications, coated conductor applied to superconducting fault current limiters(SFCLS) bypasses fault current to its stabilizer, where the surge is abruptly reduced ; thus, stainless steel, which has large resistivity can be a suitable stabilizer for SFCLS. Despite high n-value of the YBCO, CC stabilized with stainless steel did not effectively limit the first peak fault current. In the short circuit test results of AMSC's 344S, a half period delay was observed between the fault and the generation of resistance(60Hz). In this paper, we performed short-circuit experiments with stacked and unstacked CC and compared the test results to analyze effective fault current limiting characteristics. we compared time of the generated resistance as the fault current limiting characteristics and made the samples one is the stacked CC and the other is unstacked CC. These samples were used equal numbers of pieces of CC. In addition, comparison and analysis was made for the stacked structure by measuring fault current limiting characteristics with respect to thermal insulation by impregnating with epoxy resin.

Performance Analysis Based on Bonded Surface Designs for Stitchless Welded Products

  • Kim, Keum-Wha;Choi, Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.6
    • /
    • pp.583-591
    • /
    • 2012
  • This study selected three model designs used for air injection type welding clothes designed for insulation purposes and analyzed the performance of each design. The bending characteristics were analyzed in order to identify the flexibility of the welded areas; subsequently, the seam breaking strength and water pressure resistance were analyzed to identify the bonding strength. In addition, two types of waterproof fabric, polyurethane (PU) coated 2 layer and PU laminated 2 layer fabrics, were used for a performance analysis, according to fabric processing specifications. The circle type showed the highest flexibility in the terms of bending characteristics that influence wearability and were followed by the wave and the straight type. In terms of breaking strength, the straight type showed the highest breaking strength, followed by the wave and the circle type. The water pressure resistance analysis found that the wave type was superior to the straight type in terms of water pressure resistance. The wave type is deemed to be a design type suitable for maximizing performance, provided that the issue of stabilization in the welding production process is addressed. Looking at the bending characteristics of waterproof fabric for each specification, the laminating waterproof cloth outperformed the coated waterproof cloth in terms of flexibility. However, in terms of seam breaking strength, the coated waterproof cloth outperformed the laminated cloth. In contrast, the water pressure resistance of the laminated waterproof fabric was found to be higher than the coated waterproof fabric, leading to the conclusion that the bonding strength of the laminated waterproof fabric is higher than that of the coated waterproof fabric based on the assumption of injecting air.