• 제목/요약/키워드: Insulation Strength

검색결과 636건 처리시간 0.032초

Epoxy/MICA 복합체의 MICA 충진함량 변화에 대한 기계적, 전기적 특성연구 (A Study on Mechanical, Electrical Properties of Epoxy/MICA Composites with MICA Filled Contents)

  • 박재준
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.219-227
    • /
    • 2013
  • This paper reported a study on the thermal, mechanical and electrical insulation properties of epoxy/mica composites. To investigate the effect of mica content, glass transition temperature, mechanical properties such as tensile and flexural strength, and insulation breakdown properties for epoxy composites with various contents of mica. The effect of insulation thickness on insulation breakdown property was also studied. It was observed that tensile and flexural strength decreased with increasing mica content, while elastic modulus increased as the mica content increased. AC insulation breakdown strength for all epoxy/mica composites was higher than that of neat epoxy and that of the system with 20 wt% mica was 14.4% improved. As was expected, insulation breakdown strength at $30^{\circ}C$ was far higher than that at $130^{\circ}C$, and it was also found that insulation breakdown strength was inversely proportion to insulation thickness.

나노 실리카 충진함량 변화에 따른 EMNC의 특성 연구 (2) -기계적, 전기적 특성 중심으로- (Properties of EMNC According to Addition Contents Variation for Nanosilica (2) -For Mechanical, Electrical Properties)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제25권11호
    • /
    • pp.886-894
    • /
    • 2012
  • In order to develop electrical insulation materials, epoxy-nanosilica-microsilica mixture composites (ENMC) was synthesized, and mechanical properties such as their tensile and flexural strength, and AC insulation breakdown strength were investigated. Properties of mechanical strength and AC insulation breakdown strength are analyzed as scale and shape parameter with respect to weibull plot. Their tensile and flexural strength, AC insulation breakdown strength were compared original epoxy or EMC to ENMC. The 4 phr nano-silica addition and the 65 wt% micron-silica mixture composite (ENMC) was found to have the highest tensile and flexural strength. In the tensile strength was improved 29%, and flexural strength was improved 60.9% higher than those of the original epoxy. In the insulation breakdown strength, ENMC_4 phr was improved 17% and ENMC_5 phr was improved 15.8% higher than those of the EMC.

Electrical Insulation Breakdown Strength in Epoxy/Spherical Alumina Composites for HV Insulation

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권2호
    • /
    • pp.105-109
    • /
    • 2013
  • In order to develop high voltage (HV) insulation materials, epoxy/spherical alumina composites with two different particle sizes (in ${\mu}m$) were prepared and a dynamic mechanical analysis (DMA) and electrical insulation breakdown strength test were carried out in sphere-sphere electrodes and the data were estimated using Weibull statistical analysis. Alumina content varied from 50 to 70 wt%. The electrical insulation breakdown strength for epoxy/alumina (50 wt%) was 44.0 kV/1 mm and this value decreased with increasing alumina content. The effects of insulation thickness and alumina particle size on the insulation breakdown strength were also studied. The insulation thickness varied from 1 mm to 3 mm, and the particle sizes were 7.3 or $40.3{\mu}m$.

다층형 단열재의 구성 형식에 따른 강도 특성 연구 (Strength Properties of Multi-layered Insulation according to the Type of Configuration)

  • 류화성;신상헌;송성용;김득모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.141-142
    • /
    • 2019
  • As part of the recent low-energy policy, insulation standards for buildings are increasing every year. In addition, the conventional styrofoam heat insulation material has a problem in that the thickness of the heat insulation material to achieve the standard heat transmission rate is rapidly increased. Although the risk of spreading the structure vulnerable to fire due to insufficient spacing between buildings due to thickened insulation is increasing, the high cost of high efficiency insulation is difficult to solve. On the other hand, it is known that the method to be used as a formwork using insulation is excellent in cost reduction effect by reducing the amount of formwork used and simplifying the subsequent insulation work. The purpose of this study is to evaluate the strength characteristics of multi - layered insulation materials with appropriate strength by reducing the thickness of the insulation by appropriately combining high performance phenolic foam insulation and styrofoam insulation.

  • PDF

Physical Properties of Cement System Insulation Using Blast Furnace Slag

  • Seo, Sung Kwan;Park, Jae Wan;Cho, Hyeong Kyu;Chu, Yong Sik
    • 한국세라믹학회지
    • /
    • 제55권1호
    • /
    • pp.61-66
    • /
    • 2018
  • In this study, fabrication method of inorganic insulation were studied to reduce $CO_2$ from buildings. Main materials for inorganic insulation were used cement, blast furnace slag and aluminum powder as foaming agent. Mixing ratio of cement and slag was controlled and physical properties of inorganic insulation were analyzed. When inorganic insulation was fabricated using cement and slag, expanded slurries were not sunken and hardened normally. Pore size was 0.5 - 2 mm; mean pore size was about 1mm in inorganic insulation. Compressive strength of inorganic insulation increased with curing time and increased slightly with cement fineness. However, specific gravity decreased slightly with curing time; this phenomenon was caused by evaporation of adsorptive water. When inorganic insulation was dried at $60^{\circ}C$, compressive strength was higher than that of undried insulation. The highest compressive strength was found with a mixture of cement (50%) and slag (30%) in inorganic insulation. Compressive strength was 0.32 MPa, thermal conductivity was 0.043 W/mK and specific gravity was $0.12g/cm^3$.

A Study on the Physical Properties of Mineral Hydrate Insulation Material Mixed with Basalt Fiber

  • Park, Jae-Wan;Chu, Yong-Sik;Seo, Sung-Kwan;Jeong, Jae-Hyen
    • 한국세라믹학회지
    • /
    • 제53권1호
    • /
    • pp.63-67
    • /
    • 2016
  • Mineral hydrate is a new insulation material that compensates for the defects of existing materials. Mineral hydrate is made of inorganic ingredients; therefore, it is nonflammable. The porous structure of mineral hydrate makes the material lightweight and insulating. Mineral hydrate insulation and similar products have been studied and manufactured in Korea and abroad. However, these insulation materials need to improve in terms of strength. In this study, basalt fiber was used to enhance the strength. In order to observe the property changes, compressive strength, heat conductivity, and specific gravity were measured and XRD pattern analysis was performed. These tests confirmed that basalt fiber was effective at improving the strength and lowering the heat conductivity of mineral hydrate insulation.

Effect of Mixing Ratio of Spherical Silica on the Electrical Insulation Breakdown Strength in Epoxy Composites

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권2호
    • /
    • pp.101-104
    • /
    • 2013
  • The effect of the mixing ratio of spherical silica on the electrical insulation breakdown strength in an epoxy/silica composite was studied. Spherical silicas with two average particle sizes of $5{\mu}m$ and $20{\mu}m$ were mixed in different mixing ratios, and their total filling content was fixed at 60 wt%. In order to observe the dispersion of the silicas and the interfacial morphology between silica and epoxy matrix, scanning electron microscopy (SEM) was used. The electrical insulation breakdown strength was estimated in sphere-sphere electrodes with different insulation thicknesses of 1, 2, and 3 mm. Electrical insulation breakdown strength decreased with increasing mixing ratio of $5/20{\mu}m$ and the thickness dependence of the breakdown strength was also observed.

절연/반도전/절연층에 있어서 유전특성과 절연파괴 현상 (Dielectric Properties and Breakdown Strength in Insulation/Semiconductive/Insulation)

  • 강대용;오광영;김용주;박대회
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 1998
  • In this paper, breakdown strength and dielectric characteristics were experimented in the structures of insulation/insulation/insulation and insulation/semiconductor/insulation by using of insulation material of polyethylene terephthalate film. The breakdown strength and the permitivity of each specimen were measured as a function of temperature and frequency respectively. The breakdown strength of PET/PET/PET did not changed greatly but that of PET/SEMl/PEr increased as a function of temperature. As the frequency inclosed, the permitivity of PET/PET/PET and PET/SEMI/PET decreased. The tan $\delta$ of PET/PET/PET showed lower than that of PET/SEMl/PET in low frequency but higher in high frequency .

  • PDF

외단열 고정 방법에 따른 적정 접착강도 제안에 관한 연구 (A Research on Suggestion of Proper Adhesion Strength about conjugation Method of outside Insulation.)

  • 박완구;안기원;박진상;박구병;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.93-94
    • /
    • 2012
  • Recently outside insulation is applied on the building. Adhesion mortar and anchor are used fixing method of outside insulation. However, a research on proper Adhesion Strength is not performed. So outside insulation exfoliate from building in rainy with winds. Therefore, this research suggest proper adhesion strength about conjugation method of outside insulation. As a result, adhesion way using the adhesive mortar + anchor is best. And proper adhesion strength is over 1,065 N.

  • PDF

외단열 고정 방법에 따른 부착강도 변화 (Other Changes in Bond Strength due to External Insulation Method)

  • 김태준;박완구;박진상;오정환;배기선;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.132-133
    • /
    • 2013
  • External Insulation Method is to place the insulation on the outside of concrete. External Insulation Method is better than Internal Insulation Method to the protection of structure. However, The phenomenon that External Insulation falling from the structure occurs frequently. Apply method of External Insulation is divided Wet Construction, Dry Construction and Wet & Dry Construction. The purpose of this study is to test Bonding Strength of External Insuation. Furthermore, on the basis of this study, External Insulation Method determines the effective development will be made.

  • PDF