A study on supplementary measure for the vulnerable part of insulated gang form in winter (동절기 단열갱폼 취약부 보완 대책에 관한 연구)

  • Choi, Suk;Lim, Myung-Kwan;Yoo, Jung-Il;Nam, Kyung-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.138-139
    • /
    • 2022
  • Through previous studies, it was reviewed how to improve the insulation performance of weak areas by installing heated wires as a solution to the corners pointed out as weak areas when applying the insulation gang form and the existing pouring areas.

  • PDF

Characteristics of Thermal Analysis of Concrete Applied with Insulated Formwork in Winter (동절기 단열거푸집을 적용한 콘크리트 열분석 특성)

  • Nam, Kyung-Yong;Kim, Seong-Deok;Choi, Suk;Yoo, Jung-Il
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.246-247
    • /
    • 2021
  • This paper aims to quantitatively evaluate concrete quality factors according to the application of thermal insulated gang form. As a result of the experiment, it was found that the amount of calcium hydroxide produced increased in the insulated gang form than in the general gang form, and the thicker the insulation of the insulated gang form, the greater the amount of calcium hydroxide produced.

  • PDF

A Study on the Calorific Value of Insulated Gang-form in Winter (동절기 단열갱폼의 발열량 변화 측정에 관한 연구)

  • Kang, In-Seon;Won, Joon-Yuen;Kim, Tae-Hui;Kim, Seong-Deok;Choi, Seok;Nam, Kyung-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.135-136
    • /
    • 2017
  • This paper examines the efficiency of the application of conventional and insulated gang forms for curing and protection of concrete by comparing the amount of electric energy required therefor. In addition, a thermal vision camera was used to identify heat loss from surfaces of the gang forms after each placement of concrete. Experimental results, show that the heat loss at the submerged temperature was large at the submerged surface due to the large calorific value at the surface of the mold. The insulated gang form had some heat loss in the horizontal bars. In the case of adiabatic reforming, the pattern shows a constant calorific value over time. In conclusion, the insulation performance is better than that of general gang form.

  • PDF

A study on thermal properties of concrete using gang form coated with polyurethane (폴리우레탄 폼을 도포한 갱폼사용에 따른 콘크리트 온도이력특성)

  • Nam, Kyung-Yong;Won, Joon-Yuen;Kang, In-Seon;Jeon, Pan-Keun;Lee, Young-Do;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.11-12
    • /
    • 2011
  • This study examine Effect of Change of Compressive Strength of Concrete Members with Insulating Gang form on Temperature History of Concrete Positions. Test show, insulating gang forms differences and gang forms have 10℃ on peak point temperature of surface and Center if temperature history have 24Mpa by change of compressive strength. In addition, there have 14℃(16℃) on peak point temperature of surface and Center if temperature history have 40(60)Mpa. Therefore, insulating gang forms have an effect insulating performance.

  • PDF

A Study on the Energy Consumption Cost in the Winter and Calorific Value by Insulated Gang-form (단열갱폼 적용에 따른 동절기 보양비 사용량 및 발열량 검토에 관한 실험적 연구)

  • Nam, Kyung-Yong;Choi, Suk;Ahn, Sung-Jin;Lim, Myung-Kwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • This paper aims to examine the insulation performance of insulated gang form by changing the energy (power) consumption and concrete calorific value to assist in concrete protection in cold weather. According to the test results, the general gang form will generate three times the energy (power) consumption for 12 hours after the concrete is poured. In contrast, insulated gang foam consumed no energy (power) for 21 hours after pouring. The final power consumption was 3.7 times higher than that of the general gang form, confirming the improved performance of insulated gang form with regard to energy (power) consumption. The calorific value examination shows that the calorific value changes significantly according to the change of outside temperature after concrete placement in the case of the general gang form. However, in the case of the insulated gang form, only a slight heat loss occurred in the part of the frame, and it showed a constant heating pattern from the concrete casting to the demolding of the mold.

The sound insulation performance of eco-friendly loess brick wall (친환경 황토벽체의 차음성능 평가에 관한 연구)

  • Lee, Tai-Gang;Kim, Yul;Song, Kook-Gon;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.13-18
    • /
    • 2009
  • Korean traditional houses have been developed in harmony with natural environment and comfortable indoor condition by using the natural resources including building layout, space composition and materials. Originally Korea traditional architectures have used wood lintel constructions and loess walls through the many years. Theses loess have many strength such as highly heat capacity, controling of humidity, a deodorant than any other materials. Nowaday it is recommended to use exterior and interior walls in loess wall to meet the eco-friendly materials to improve our residental environmental. Thus this study aims to research the sound insulation performance of traditional loess brick wall varied with thickness, thermal insulation materials and cavity wall. The sound insulation performance of these loess walls are compared with other masonry wall's and sound insulation performance of th walls were tested in anechoic laboratory to measure the sound transmission loss of these walls. The loess brick wall with 75mm thickness of cavity is shown the sound insulation performance with Rw 57 which is nearly same performances of 1B brick wall and cement 8' block wall, The improving effect of insulation materials is shown in the high frequency bandwidth. Especially, there is improving as much as 11 dB using the extruded poly stylene form(75mm) and poly ethylene film(0.7mm).

Revitalization Methods of EIFS for High-rise Residential Buildings through Using TACT and Gangform System with Hanging Scaffolding

  • Lee, Sang-Hyun;Yi, June-Seong;Shin, Seung-Woo;Kang, Hae-Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.407-418
    • /
    • 2011
  • Recently energy management measures at the political level, for the purpose of reducing energy consumption in the building sector, are being actively introduced. As a practical method, the exterior insulation method, which is proven to effective in reducing the energy loss through walls, has been favored. In this study, detailed implementations are suggested to activate exterior insulation system which can improve the housing insulation performance. The newly designed Gang-form system with hanging scaffolding was suggested to revamp constructability for finishing outer wall. The research results are based on a multifaceted analysis of the current problems of exterior insulation systems, and on recommendations proposed by exterior insulation experts in the Charrette discussion. The study has indicates that the customized TACT schedule considering the site condition has shortened the construction period to 5 months from 7.5 months. Through utilizing the suggestions of this study, the prevalence of exterior insulation systems is expected to become widespread.

A Study on the Economical Efficiency and Cost Analysis of Winter Construction by Application of Insulated Gang-form (동절기 단열갱폼으로 인한 경제성 효과 및 투입 원가 분석 연구)

  • Won, Joon-Yuen;Lee, Young-Do;Nam, Kyung-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.347-354
    • /
    • 2018
  • This paper verifies the superiority of warming work in winter by applying the insulation gang-form to the apartment housing site and analyzes the economic feasibility of the application. According to the experimental results, the actual cost of warming work was about 52 million won less than planned, and 160 million won less than the existing average.(Note - The cost of gang form material increased from 260 million won to 310 million won after the change) As a result, the construction cost could be reduced by about 110 million won. As the costs of warming work can change depending on the number of floors, the building number, and the area of each site, it is deemed necessary to conduct a thorough review in advance at the site where the cost of warming work is to be applied.