• Title/Summary/Keyword: Insulation Efficiency

Search Result 316, Processing Time 0.025 seconds

Design and fabrication of Ka-band high power and high efficiency waveguide spatial combiner (Ka 대역 고출력 고효율 도파관 공간 결합기 설계 및 제작)

  • Kim, Hyo-Chul;Cho, Heung-Rae;Lee, Ju-Heun;Lee, Deok-Jae;An, Se-Hwan;Lee, Man-Hee;Joo, Ji-Han;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.5
    • /
    • pp.19-26
    • /
    • 2021
  • This report proposes a waveguide spatial combiner with high power low loss. The proposed spatial combiner implements high power by combining from the center of each port through a waveguide. In particular, we implement low loss using TE01 mode, which has the lowest transmission track loss among modes of circular waveguide, and miniaturization is achieved by applying a new mode conversion method. IIn addition, it was confirmed that it was suitable for high output by calculating the insulation breakdown voltage of the new mode conversion structure through E-field analysis. The final 8-way waveguide spatial combiner was designed and manufactured, and the insertion loss was less than 0.4dB and the combining efficiency was 97% or more, confirming that the electrical performance was very good compared to the planar combining method.

A Study on Simulation for Decreasing Energy Demand According to Window-to-Wall Ratio and Installation Blind System in Building (블라인드 도입과 창면적비에 따른 표준건축물의 에너지 수요 저감에 대한 시뮬레이션 연구)

  • Kang, Suk-Min;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.531-542
    • /
    • 2018
  • Building energy demands have highly risen in modern society; thus, It is necessary to reduce building energy demands especially commercial buildings adopting a curtain wall architecture. Curtain wall architectures have a high ratio of windows which is a vulnerable in heat insulations as cladding. In order to complement insulation performance of windows in these buildings, there are various methods adopted often such as installing blinds, wing wall and films. There are two suggestions of this paper. 1) WWR (Window-to-Wall Ratio) makes a impaction of energy demands in buildings. 2) Another one is an efficiency of blind systems which are installed in buildings in order to reduce cooling demands. It is also critical to make fundamental model for low-energy building construction by processing a lot of simulation As a result by this study, 1) an external blind system is more useful for reducing cooling energy demands rather than an internal blind system. 2) Buildings which have a large window require more amount of cooling demands. In case of WWR 45%, it needs more cooling energy rather than WWR 15% model's 3) Adopting blind system would reduce energy demands. WWR 45% model with external blind systems reduces about 4% of cooling energy demands compared to same model without any blind systems.4) it is necessary to study an efficiency of blind systems combined with renewable energy and it will be possible to reduce more energy demand in building significantly.

Buckling Formation on Steel-Based Solar Cell Induced by Silicone Resin Coat and Its Improvement on Performance Efficiency (실리콘 고분자 수지의 버클링을 통한 스틸기반 태양전지의 효율 향상)

  • Park, Young Jun;Oh, Kyeongseok
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.519-524
    • /
    • 2019
  • Even though stainless steel foil is not a highly efficient material for film-type solar cell, it has strong passivation capability without additional process. In this study, silicone resin was employed during a-Si:H thin film solar cell fabrication for the purpose of planarization and electrical insulation. In the first stage of process, silicone resin was coat onto the stainless steel (STS) using spin coater with thickness of $2{\sim}3{\mu}m$ and followed by aluminum deposition using ion beam application. Unexpectedly buckling was formed during aluminum deposition process. After subsequent fabrication processes, solar cell performance was evaluated. In voltage-current data, slight increase of cell performance was obtained and interpreted by the increase of light scattering.

Evaluating Performance of Energy Conservation Measures for Remodeling Educational Facilities - Focused on Deteriorated Middle School Buildings - (교육시설 리모델링을 위한 에너지 절감 요소기술의 성능 평가 - 노후 중학교 건물 중심으로 -)

  • Lhee, Sang-Choon;Choi, Young-Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.105-110
    • /
    • 2012
  • Recently, all of the world are facing with a serious environmental crisis of global warming due to excessive energy consumptions. The Korean Government, taking over 97% of dependence on foreign energy, has made various efforts on reducing energy and greenhouse gas emission under the motto of "Low-Carbon Green Growth". Since the building sector takes 24% of domestic energy consumption, many design standards and regulations on saving energy in new buildings have been established. However, applications of energy saving designs and techniques on the remodeling process at deteriorated buildings including educational ones have been lack. Under a situation where the number of deteriorated schools accounts for up to 50%, this paper evaluated the performances of factors for reducing energy at deteriorated middle school buildings through an energy simulation tool on a standard school model. As a result, among factors of insulation, window's SHGC, southern louver, indoor setup temperature, and system efficiency, all other factors except window's SHGC and southern louver proved contribute to reduce energy at deteriorated middle school buildings, compared with the baseline energy consumption.

Wing Technique: A Novel Approach for the Detection of Stator Winding Inter-Turn Short Circuit and Open Circuit Faults in Three Phase Induction Motors

  • Ballal, Makarand Sudhakar;Ballal, Deepali Makarand;Suryawanshi, Hiralal M.;Mishra, Mahesh Kumar
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.208-214
    • /
    • 2012
  • This paper presents a novel approach based on the loci of instantaneous symmetrical components called "Wing Shape" which requires the measurement of three input stator currents and voltages to diagnose interturn insulation faults in three phase induction motors operating under different loading conditions. In this methodology, the effect of unbalanced supply conditions, constructional imbalances and measurement errors are also investigated. The sizes of the wings determine the loading on the motor and the travel of the wings while their areas determine the degree of severity of the faults. This approach is also applied to detect open circuit faults or single phasing conditions in induction motors. In order to validate this method, experimental results are presented for a 5 hp squirrel cage induction motor. The proposed technique helps improve the reliability, efficiency, and safety of the motor system and industrial plant. It also allows maintenance to be performed in a more efficient manner, since the course of action can be determined based on the type and severity of the fault.

Melting Characteristics of Asbestos Cement Slate on Basicity Control (염기도 조절에 의한 석면슬레이트 용융특성)

  • Yun, Jinhan;Keel, Sangin;Min, Taijin;Lee, Chungkyu;Jang, Duhun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.159.2-159.2
    • /
    • 2010
  • Asbestos is the collective name for a group of naturally occurring minerals in their fibrous form and hydrous silicates of magnesium and a mineral fiber that has been used commonly in a variety of building construction materials for insulation and as a fire-retardant. Asbestos has been used for a wide range of manufactured goods, because of its fiber strength and heat resistant properties. Nevertheless harmful of asbestos is quite serious. Exposure to airborne friable asbestos may result in a potential health risk because persons breathing the air may breathe in asbestos fibers. Continued exposure can increase the amount of fibers that remain in the lung. Fibers embedded in lung tissue over time may cause serious lung diseases including asbestosis, lung cancer. In this paper, we carried out as fundamental study for dispose of asbestos cement slate safely and perfectly. Melting Temperature of asbestos need to more than $1,520^{\circ}C$ and specially asbestos cement slate need more energy than that of pure asbestos. We need to decrease melting temperature of asbestos cement slate for economical efficiency. To the purpose, glass and bottom ash were chosen as additives for basicity control. we analyzed about properties of asbestos cements slate, melting characteristics on the additives ratio and temperature. We confirmed about harmlessness of melting slag through analysis of scanning electron microscope(SEM) and x-ray diffractometer(XRD).

  • PDF

A Study on the Development of Building Envelope Elements for Energy Reduction in Multi- Rise Residential Buildings

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.18 no.4
    • /
    • pp.151-155
    • /
    • 2016
  • It is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to find an optimal thermal transmittance (U-values) for building envelope elements for low energy multi-rise residential buildings in the early design phase in Korea. The study found that using small U-values of $0.15w/m^2K$ for exterior walls, ceilings and floors and $1.0w/m^2K$ for south and north facing windows has resulted in energy reduction of 22.1%-59.4% in the south facing rooms and 43%-77.6% of the north facing rooms. It has also found the energy load reduction potential of using small U-values are higher on the north facing rooms. The findings of this study can be suggested to be used as a baseline case for low energy consumption studies. It can also be used to determine appropriate envelope materials and insulation values.

A Study on the Improving Direction of Container Housing through Field Survey - Based on the Analysis of 12 cases in the Urban Area - (국내 컨테이너 하우징의 실태조사를 통한 개선방향연구 - 수도권 지역의 12개 사례를 중심으로 -)

  • Yoo, Hae-Yeon;Park, Yeon-Jeong;Yoon, Jung-Yeon
    • Journal of the Korean housing association
    • /
    • v.23 no.6
    • /
    • pp.21-30
    • /
    • 2012
  • In foreign countries, the use of containers has already been stabilized with their advantages utilized in various forms. Containers are also utilized in Korea as various forms of architecture, but domestic container buildings have poor public consciousness so as to be limitedly utilized as temporary structures based on economic efficiency. Besides, there is the lack of research and development on them. Particularly, despite the advantages of containers as housing facilities, the use of containers as short- or middle-term temporary housing is limited and does not spread. Also, compared to general housing, containers have lower quality of physical environment and even frequently bring about negligent accidents such as fire and electric shock. Thus, this study intends to identify the actual condition of using container houses, the problems in using them, and the direction of improving their residential environment. For this purpose, it analyzes the present condition and characteristics of domestic container housing, and derives conclusions from the focus group interview with 23 residents who have lived in Seoul and Gyeonggi-do for over a year about such survey items as daylighting, ventilation, privacy condition, water service and sewerage, insulation, soundproofing, view, and room scale.

An Enhanced Secure Health Data Transmission Protocol using Key Insulation in Remote Healthcare Monitoring System (원격 헬스케어 모니터링 시스템에서 키 격리기법을 이용한 개선된 건강정보 전송 보안 프로토콜)

  • Noh, Si-Wan;Park, Youngho;Rhee, Kyung-Hyune
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.12
    • /
    • pp.1981-1991
    • /
    • 2016
  • In recent, the advancement of wearable devices and wireless body area networking technologies motivate researchers to pay attention to remote healthcare system for monitoring patients health and disease progression effectively. However, in order to implement a practical remote healthcare system, we must consider the security and privacy of patient's personal health information transmitted to healthcare servers through the network. Hence, in this paper, we propose a secure health data transmission protocol in remote healthcare monitoring system to protect patient's health information and prevent privacy from eavesdropping on the network. To achieve our security goals, we design an efficient secure protocol based on the identity-based cryptography with key evolution technique, and then confirm the superiority and the efficiency of the proposed protocol as compared with the existing protocol of Yang et al.

A Novel Noise Reduction Method for Measuring Partial Discharge in High Voltage Electric Machinery (고압 전기설비 부분방전시험을 위한 노이즈 저감방안)

  • Lee, Young-Jun;Park, Kwang-Ha;Choi, Hyung-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2021_2022
    • /
    • 2009
  • Partial discharges(PD) is a important factor to evaluate the insulation state in high voltage electric machinery. However, measuring PD under the circumstances of power plant is occasionally impossible due to the relatively high magnitude of noise which is emanated from the operating machinery. In some case, the instrument measuring PD can not even perform a calibration that initializes tools and enhance the accuracy. This paper presents that we devised a noise reduction method and demonstrated the usefulness in acquiring reliable PD signals. We attached a series of filter and transformer at the input of power source of the instruments which refrains high noise signals from incoming to the instruments. We experimented the efficiency of noise reduction applying the device into the Dangjin Power Plant and Factory. As a result of testing with the filter and transformer, we can easily calibrate the PD signal compared to the case without the device. Additionally, we can detect the small PD signal which was unperceived with a normal device.

  • PDF