• 제목/요약/키워드: Insulation Design

검색결과 893건 처리시간 0.029초

여유턴 방식에 의한 가스변압기의 절연 설계에 관한 연구 (A Study of Insulation Design of a Gas Transformer Using Extra Turns.))

  • 허우행;하영식;홍정표;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권3호
    • /
    • pp.115-121
    • /
    • 2001
  • This paper deals with the electrical insulation design of a gas insulated power transformer based on extra turns method satisfying the impulse test performed in the worst condition. The calculation of electrical strength in insulation structure was done by 2D finite element method. The gas insulated power transformer was manufactured by selecting the optimum arrangement among design results. the validity of the design result is verified by the impulse test of manufactured machine.

  • PDF

EPS Bead 혼입비율에 따른 CLC의 단열특성 (Insulation Properties of CLC according to Mixing Ratio of EPS Bead)

  • 이정택;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.45-46
    • /
    • 2023
  • CLC is used as a filling material for many buildings, and according to energy saving design standards, CLC also requires insulation performance. However, it shows lower insulation performance compared to organic insulation, so additional research is needed. Therefore, in this study, the insulation properties of CLC were analyzed by incorporating EPS beads with high insulation performance into CLC. In this experiment, EPS beads and blast furnace slag were replaced, and W/B was fixed at 33%. The EPS Bead mixing ratio was divided into 5 levels: 0, 0.5, 1.0, 1.5, 2.0 (%), and the experimental items were measured for apparent density and thermal conductivity. As a result of the experiment, the apparent density and thermal conductivity tended to decrease as the mixing ratio of EPS beads increased. It is judged that the density decreased due to the low density and the micropores inside, and the thermal conductivity also decreased.

  • PDF

공기주입형 의복의 보온력 측정 및 다운재킷의 보온력과의 비교 (Comparisons of Thermal Insulations between on Air-Cell Pack Embedded Jacket and Down Jackets)

  • 김영빈;장원;김기림;김시연;백윤정;이주영
    • 한국의류학회지
    • /
    • 제39권1호
    • /
    • pp.55-62
    • /
    • 2015
  • This study investigated the thermal insulation of an air-cell pack embedded jacket and down jackets to understand the potential of air-cell pack as a filler for winter outdoor wear. A thermal manikin measured the thermal insulation of the following jackets: HD (heavy down jacket, total weight (Tw) 750g, goose down weight (Dw) 350g), LD (light down jacket, Tw 560g, Dw 140g), AF (air-cell pack embedded jacket, Tw 490g, trunk goose down in LD was replaced to air cell), F (film jacket, Tw 469g, but removed the air in the air-cell pack from the AF), and Control (control jacket, Tw 438g, removed the air-cell pack film from the F). Thermal insulations of each experimental condition were measured in a static standing posture. Total thermal insulations (IT) were 1.29clo (HD), 1.23clo (LD), 1.16clo (AF), 1.20clo (F), and 1.08clo (Control). Body regional thermal insulation was higher in the chest and back than in the abdomen and hip in all conditions. The results suggest that an economical and versatile outdoor jacket with superior thermal insulation will be feasible if the air volume is properly controlled in air-cell pack embedded jackets in consideration of regional different distribution and used in combination with film and down.

금속단열재 박판의 설계인자별 단열성능 영향 연구 (Studies on Insulation Effect Related with Thin-Plate Design Factors for Reflective Metal Insulation(RMI) of Nuclear Power Plant)

  • 어민훈;이성명;장계환
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.350-354
    • /
    • 2016
  • Although fibrous insulations are generally used with resistive insulation type, metallic insulation is proper matter to satisfy low head-loss and equipment life when considering the specific condition, especially for Nuclear power plant. Common insulation is resistance insulation with a low thermal conductivity. but RMI is made of sheet plate with low emissivity and closed air space. Thermal radiation is blocked by stainless steel with low emissivity. Thermal conductivity and thermal convection are blocked by closed air space. This study shows the changes and effects of the heat loss according to shape and method of stacking sheet plates inserted into the insulation and analyzed the most optimized way for thermal insulation performance. The result shows that using sheet plate structure through raised and protruding shape processing was the appropriate model to optimize thermal performance. Additionally, insulating performance of RMI improved by placing the sheet plate in a high temperature region intensively.

건축물 준공년수 경과에 따른 단열재의 물성변화에 관한 연구 (A Study on the Physical Properties of Insulation Materials according to the Period of Building Construction)

  • 김현진;최세진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.92-93
    • /
    • 2018
  • This study analyzed the physical properties of insulation materials upon completion of building completion years and found the suitability of the current energy performance analysis methodology to apply the insulation specified in the design drawings to the same thermal conductivity values as the new materials.

  • PDF

지능형 절연열화센서 개발 (Development of Intelligent Insulation Degradation Sensor)

  • 김이곤
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2002년도 추계학술대회 및 정기총회
    • /
    • pp.158-161
    • /
    • 2002
  • Many methods were proposed for insulation degradation diagnosis to High voltage and capacity Transformer in live. IDD is difficult by those methods because insulation degradation circumstances and characteristics of electrical plant are different with other Therefore, it is necessary to design diagnosis algorithms fitting for each. In this paper, We develop IIDS that used diagnosis algorithm with fuzzy model and hardware with MCU.

초등학교 실내공간 디자인의 환경친화적 특성에 관한 연구 - 부산시와 오사카시 초등학교 사례를 중심으로 - (A Study on the ecological design elements of elementary school interior - Focused on the elementary schools of Osaka, Japan and Busan, Korea -)

  • 윤지영;송주은
    • 한국실내디자인학회논문집
    • /
    • 제14권3호
    • /
    • pp.46-54
    • /
    • 2005
  • This study explored how the elementary schools provided proper interior environments to the students in terms of ecological aspects. 14 cases-7 in Busan and 7 in Osaka which were newly built or remodelled since 2000 were selected. These schools were analyzed based on the eco-school guideline suggested In the former study. The guideline categorizes into three parts: 1) energy efficiency related with lighting, ventilation, heating and insulation, 2) greening, 3) sustainability including recycling water system and use of environmentally friendly materials. The results showed that Korean schools require more systematic planning for natural lighting, ventilation, Insulation, greening and new water system while Japanese schools need use of environmentally friendly materials and consideration for natural lighting, insulation and interior greening. Especially, natural lighting and natural ventilation through roof window, atrium, wind tower and use of natural insulation and blind window system should be basically considered at the Initial planning. Also, this study reveals that ecological approach including greening and natural lighting with various architectural form should be applied in future elementary school design to make the school environment more agreeable and economical.

E종 절연 유도 전동기의 설계 (Design of Class E Insulation Induction Motor)

  • 이승원
    • 전기의세계
    • /
    • 제16권2호
    • /
    • pp.1-8
    • /
    • 1967
  • From the discovery of Alago's disk, a number of trials and efforts have been concentrated on a small-sized and light-weighted induction motor. They have devoted themseleves, however, mainly to a improvement of cooling effect, a proper weight-distribution of copper and iron and desirable number of slots. In consequence, such an effort restricted only to the field of design, has resulted in unsatisfactory developments in the insulating materials consisting of the main parts of an induction motor. The quality of fibre and paper which are used as class-A insulation materials with their "compound" and "varnish" has been increased to some extent. Similarly Class-B insulation materials like asbest mica has been almost a combination of inorganic and binding materials. But nowadays synthesic chemistry is making a remarkable progress. So it comes possible for us to have silicon resin and other good ones of similar charateristics. And even a thin silicon resin insures us to get excellent heat-pro f and insulation, so a better space factor and cost-down in motor design have come possible in most advanced nations of the world, but not in our country. Furthermore, a consideration of productivity and economy in manufacturing process has been neglected by a majority of engineers. This is more unpleasant und more undesirable. I think this rational method of induction motor design using new synthesic resin will devote in making your productivity and economy better. And the nation-wide standard value of electric motor size is sited here. size is sited here.

  • PDF

600kJ급 전도냉각 HTS SMES의 미니모델 제작 및 절연평가 (The Manufacture and Insulating Test of Mini-model for 600kJ Class Conduction Cooled HTS SMES)

  • 최재형;곽동순;천현권;민치현;김해종;김상현
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.588-593
    • /
    • 2007
  • The 600kJ class high temperature superconducting magnetic energy storage (HTS SMES) system is being developed by Korean Electrotechnology Research Institute (KERI). The system is operated in cryogenic temperature and high vacuum condition. The SMS magnet was cooled by conduction cooling method using a Gifford-McMahon cycle cryocooler. Thus, electric insulation design at cryogenic temperature and high vacuum is a key and an important element that should be established to accomplish compact design is a big advantage of HTS SMES. This paper describes the electric insulation design, fabrication and experimental results for a mini model of conduction cooled HTS SMES.

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500kV Substations

  • Ju Hyung-Jun;Lee Heung-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.366-370
    • /
    • 2005
  • To meet increasing power demand, 500 kV power systems are under consideration in the regions of some Middle Asian countries. As the power system voltage becomes higher, the cost for the power system insulation increases significantly. 500 kV transmission systems will become the basis of a region's power system and they require much higher system reliability. Consequently, by the methods of limiting overvoltages effectively, a reasonable insulation design and coordination must be accomplished. In particular, the Substations must be constructed to be of outdoor type. In order to determine the various factors for the insulation design, the EMTP (Electro-magnetic transient program) is used for the magnification of transient phenomena of the 500 kV systems in the planned network. In this paper, we will explain the calculation results of lightning overvoltages by the EMTP for lightning protection design for the 500 kV substations. To obtain reliable results, the multi-story tower model and EMTP/TACS model are introduced for the simulation of dynamic arc characteristics.