• 제목/요약/키워드: Insulating Paper

검색결과 491건 처리시간 0.026초

VPI Varnishing Technology Effects on Frequency Characteristics of an Air Core Inductor Used in LISN Circuit Application

  • Kanzi, Khalil;Kanzi, Majid;Nafissi, Hamidreza
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.57-64
    • /
    • 2013
  • The functional characteristic of LISN circuit, which is used for measurements of conductive noise in mains power line, is basically related to frequency characteristics of passive elements like inductors used in the circuit as well as the frequency response of inductors is highly related to the resins used in the varnishing process. The significant problem in determination of an inductor's frequency characteristic is the intrinsic resistance, inductance and parasitic capacitance. In this triplet, the parasitic capacitance is the major limiting factor of inductor's frequency range. This capacitance depends on inductor design parameters and materials filling the spaces of coil like resin and its coherency after curing process. In this paper, two similar inductors were designed and built. The first inductor was not varnished while the second one was varnished with VPI technology. VPI, or Vacuum, Pressure, Impregnation technology is one of the most reliable methods performing good insulating conditions for electrical circuits and windings based on resins. The measured results show that implying varnishing technology does not significantly affect the frequency response. However, due to mechanical solidity aspects and improved environmental protection, it is better to varnish the inductors.

Preparation of Epoxy/Organoclay Nanocomposites for Electrical Insulating Material Using an Ultrasonicator

  • Park, Jae-Jun;Park, Young-Bum;Lee, Jae-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권3호
    • /
    • pp.93-97
    • /
    • 2011
  • In this paper, we discuss design considerations for an n-channel metal-oxide-semiconductor field-effect transistor (MOSFET) with a lateral asymmetric channel (LAC) doping profile. We employed a 0.35 ${\mu}M$ standard complementary MOSFET process for fabrication of the devices. The gates to the LAC doping overlap lengths were 0.5, 1.0, and 1.5 ${\mu}M$. The drain current ($I_{ON}$), transconductance ($g_m$), substrate current ($I_{SUB}$), drain to source leakage current ($I_{OFF}$), and channel-hot-electron (CHE) reliability characteristics were taken into account for optimum device design. The LAC devices with shorter overlap lengths demonstrated improved $I_{ON}$ and $g_m$ characteristics. On the other hand, the LAC devices with longer overlap lengths demonstrated improved CHE degradation and $I_{OFF}$ characteristics.

The Lightning Impulse Properties and Breakdown Voltage of Natural Ester Fluids Near the Pour Point

  • Choi, Sun-Ho;Huh, Chang-Su
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.524-529
    • /
    • 2013
  • Recently, researchers have become interested in natural ester fluids, as they are an environmentally friendly alternative to mineral oils. Natural ester fluids are a natural resource made from plants; they have higher biodegradability, flash, and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester fluids also have a higher pour point, viscosity, and water content. These characteristics can hamper circulation and impair the electrical properties of an oil-filled transformer. A large amount of data has been accumulated over the years in regards to mineral insulating oil involving dielectric breakdown voltage and lightning impulse tests. However, natural ester fluids have not had their electrical properties sufficiently characterized. In this paper, we present an investigation into the characteristics of the electrical discharge development in natural ester fluids and in an oil-filled transformer near the pour points. The experiment results show that the electrical properties decreased according to a decrease in the ambient temperature and freezing time. It was found that the pour point and water content of natural ester fluids have a significant effect on the electrical properties.

수중에서의 인체에 대한 전격위험성 분석 (Analysis of Electric Shock Risk of the Human Body in Underwater)

  • 김성철;김두현;이종호;김종민
    • 한국안전학회지
    • /
    • 제21권6호
    • /
    • pp.26-32
    • /
    • 2006
  • The paper considers the electrical shock risk of the human body due to underwater leakage current in electric field. The characteristics of electric shock in fresh water due to the leakage of submerged electric facility in the bathtub in public baths were conducted. The exposed live electrode is modeled as a point source of electric current source. It is assumed that divergent monopole field exists in the vicinity of the current source, regardless of the presence of return electrode and insulating boundary. The electric potentials in the steel bathtub, Diesen and Mole and Flux3D program one are measured according to the distance from leakage source. The results show that the increased shock risk and safe distance are estimated by the bathtub of limited width and the voltage calculated on the basis of a divergent monopole field concept is compared with the measured value.

제어 시스템 적용을 위한 ER유체의 빙햄 특성에 관한 기초적 연구 (A Fundamental Study on Bingham Characteristics of Electro-Rheological Fluids for Control System Application)

  • 장성철;정영빈;장길식
    • 한국기계가공학회지
    • /
    • 제3권3호
    • /
    • pp.86-92
    • /
    • 2004
  • This paper describes the properties of temperature-viscosity characteristics of hydrous and anhydrous electro-rheological fluids containing starch and titanium particle in silicone oil ER effects arise from electrostatic forces between the starch particles and titanium particles dispersed to the electrically insulating silicone oil induced when electric field is applied ER fluids under electric field control have been found to provide resonable estimates of ER fluid viscosity variation characteristics. Yield shear stress of the ER fluids were measured the couette cell type rheometer as a function of electrlc fields. The outer cup is connected to positive electrode(+) and bob becomes ground(-). The electrie field is applied by high voltage DC power supply. In this experiment shear rates were increased from 0 to 200 $s^{-1}$ in 2 minutes. The ER fluid's viscosity change is very small and stable at the temperature range of $40^{\circ}C$ to $60^{\circ}C$. Therefore, applications of a new ER fluid to control systems application are suitable.

  • PDF

난연성 폴리 올레핀 케이블 절연재료의 내화특성 (Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant)

  • 윤헌주;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

A Study on the properties of aluminum nitride films on the Al7075 deposited by pulsed DC reactive magnetron sputtering

  • Kim, Jung-hyo;Cha, Byung-Chul;Lee, Keun-Hak;Park, Won-Wook
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 추계총회 및 학술대회 논문집
    • /
    • pp.179-180
    • /
    • 2012
  • Aluminum alloys are widely known as non-ferrous metal with light weight and high strength. Consequently, these materials take center stage in the aircraft and automobile industry. The Al7075 aluminum alloy is based on the Al-Zn-Mg-Cu and one of the strongest wrought aluminum alloys. Aluminum nitride has ten times higher thermal conductivity($319W/m{\cdot}K$) than Al2O3 and also has outstanding electric insulation($1{\times}1014{\Omega}{\cdot}cm$). Furthermore, it has high mechanical property (430 MPa) even though its co-efficient of thermal expansion is less than alumina For these reasons, it has great possibilities to be used for not only the field which needs high strength lightweight but also electronic material field because of its suitability to be applied to the insulator film of PCB or wafer of ceramic with high heat conduction. This paper investigates the mechanical properties and corrosion behavior of aluminum alloy Al7075 deposited with aluminum nitride thin films To improve the surface properties of Al7075 with respect to hardness, and resistance to corrosion, aluminum nitride thin films have been deposited by pulsed DC reactive magnetron sputtering. The pulsed DC power provides arc-free deposition of insulating films.

  • PDF

산화아연소자의 성형공정에 따른 전기적 특성과 성능평가 (Electrical Characteristics and Performance Evaluation with Manufacturing Process of Zinc Oxide Varistors)

  • 조한구;윤한수;김석수;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제19권11호
    • /
    • pp.1061-1066
    • /
    • 2006
  • This paper presents the electrical characteristics with manufacturing process and performance evaluation of high performance zinc oxide varistors. ZnO varistors were fabricated with typical ceramic production methods with different thickness and the structural and electrical characteristics of ZnO varistors were investigated. All varistors exhibited high density, which was in the range of $5.41{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage increased in the range of $4.410{\sim}5.250kV$ with increasing their thickness and the residual voltage exhibited the same trends as the reference voltage. In the long duration current impulse withstand test, E-2 and F-1 samples failed at the two and four shots of impulse current, respectively, but E-1 and F-2 samples survived 18 shots during the test. Before and after this test, the variation ratio of residual voltage of E-1 and F-2 samples were -0.34 % and 0.05 %, respectively, which were in the acceptance range of 5 %. According to the results of tests, it is thought that if the fabrication process such as insulating coating, sintering condition, and soldering method is improved, these ZnO varistors would be possible to apply to the station class arresters in the near future.

대기압하의 액체질소중 트래킹현상 및 연면방전 특성 (The Characteristic of Tracking Phenomena and Surface Discharge at the atmospheric Pressure)

  • 박광서;신동화;신호영;주재현;최병주;이광식;이동인;변승봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1699-1701
    • /
    • 1998
  • This paper was studied on the surface discharge characteristics on the solid insulators in the Liquid Nitrogen($LN_2$) at atmospheric pressure. Liquid Nitrogen has been widely used as a tooling and insulating materials for superconducting and cryogenic cable. Considering the effect of bubbles, we observed tracking Phenomena on the surface of solid insulators and investigated surface breakdown characteristics of several solid insulators.

  • PDF

PIC를 이용한 다수의 전구 밝기제어에 관한 연구 (A Study on the Luminosity Control of Bulbs by Using PIC)

  • 배철오;박영산
    • 해양환경안전학회지
    • /
    • 제13권3호
    • /
    • pp.235-240
    • /
    • 2007
  • 최근 에너지 절약형 건물에 많은 관심을 기울이고 있으며, 이를 위해 보냉, 보온의 단열재 등의 건축재료 개발이 많이 이루어지고 있다. 이와 더불어 건물 내외의 온도와 밝기는 햇볕의 밝기, 위치 및 기후변화에 따라 많은 영향을 끼치므로 자연채광에 따른 건물의 위치는 건물을 짓는데 있어서 고려해야할 중요한 변수이다. 본 논문에서는 자연채광과 비슷한 조건을 만들어 모델링하기 위해 반구형의 돔으로 된 원형 지붕에 자연채광의 역할을 하는 342개의 백열전구를 인공채광으로써 설치하였다. 특히 여기서는 각 백열전구의 밝기제어에 관한 것을 중점적으로 다루고 있으며, 다수의 PIC 마이크로프로세서와 트라이악을 이용한 위상제어로 전구의 밝기를 제어한 실험결과를 제시하고 있다.

  • PDF