• Title/Summary/Keyword: Insulating

Search Result 1,644, Processing Time 0.031 seconds

Research of Flow Electrification Phenomena of the used Environment-Friendly Vegetable Insulating Oils (친환경 식물성절연유의 유동대전현상 연구)

  • Choi, Sun-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.580-584
    • /
    • 2012
  • The insulating oils perform a cooling and insulation action in electric power transformer. The mineral oil has immanent fire dangerousness and environmental contamination problem. Vegetable insulating oil has higher ignition point, flash point and more excellent biodegradability than conventional mineral oil. In a real oil-filled transformers, some of the power is dissipated in the form of heat. And transformer require the heat to be removed from the winding and insulator by forced convection of the insulating oil. The flow electrification occurs when insulating oil was forced to be circulated. In this paper, influence of temperature, velocity of flow, and insulating pipe and diameter on streaming electrification of vegetable insulating oil was investigated using forced circulation apparatus. Temperature effects were most significant, and it showed a peak in the temperature $30^{\circ}C$ to $35^{\circ}C$ at insulating and copper pipe. The change of flow electrification according to area variety could be checked by change of diameter.

Analyses on Electrical-Mechanical Characteristics of Environment-friendly Transformer Insulating Material by Accelerated Thermal Aging (가속 열 열화에 따른 환경친화형 변압기 절연물의 전기적-기계적 특성 분석)

  • Shim, Myeong-Seop;An, Jung-Sik;Choi, Sun-Ho;Jeong, Jung-Il;Lee, Tae-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1832-1838
    • /
    • 2010
  • Aging of transformer insulating material in natural ester insulating oil is compared to that in conventional transformer oil. Aging of insulating paper and insulating oil have been studied by performing accelerated thermal aging test. Sealed aging test vessels containing cooper, laminated core, Kraft paper and insulating oil(natural oil or mineral oil) were aged at $140^{\circ}C$ for 500, 1000, 1500 and 2000 hours. Insulating oils after aging are investigated with total acid number, breakdown voltage and viscosity. Also, degradation of insulating paper after aging is determined using breakdown voltage and mechanical strength. Accelerated aging studies demonstrate a slower aging rate for natural ester insulating oil compared to the rate for conventional mineral oil.

Effect of Mixing Condition of Raw Materials on the Thermal Properties of the Exothermic & Insulating (원료 배합조건에 따른 발열보온재의 열적 특성)

  • Kim, D.J.;Shin, D.Y.;Byun, S.Y.;Wi, C.H.;Hong, S.H.;You, B.D.;Oh, S.H.
    • Transactions of Materials Processing
    • /
    • v.18 no.5
    • /
    • pp.401-409
    • /
    • 2009
  • The change of the thermal properties of exothermic and insulating materials with the mixing condition of raw materials which is the most important factor for exothermic & insulating materials was investigated by using the evaluation system of the thermal properties of exothermic and insulating materials. In this study, the effect of the thermal properties of the exothermic & insulating materials such as exothermic properties, endothermic properties, insulating properties, maximum temperature of molten metal, ignition time of exothermic & insulating materials and temperature recovery time on the mixing ratio of reductant and oxidant, types of reductant, and particle sizes of reductants was examined. It could be expected to design the mixing condition of raw materials for various exothermic and insulating materials.

Effect of Mixing condition of raw materials on the Thermal Properties of the Exothermic & Insulating Materials (원료 배합조건에 따른 발열보온재의 열적 특성)

  • Kim, D.J.;Shin, D.Y.;Byun, S.Y.;Wi, C.H.;You, B.D.;Oh, S.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.118-126
    • /
    • 2009
  • The change of the thermal properties of exothermic & insulating materials with mixing condition of raw materials which is the most important factor for exothermic & insulating materials was investigated by using the evaluation system of the thermal properties of exothermic & insulating materials. In this study, the effect of the thermal properties of the exothermic & insulating materials such as exothermic properties, endothermic properties, insulating properties, maximum temperature of molten metal, ignition time of exothermic & insulating materials and temperature recovery time on the mixing ratio of reductant and oxidant, types of reductant, and particle sizes of reductants was examined. It could be expected to design the mixing condition of raw materials for various exothermic & insulating materials.

  • PDF

Effect of ceramic powder addition on the insulating properties of polymer layer prepared by dip coating method

  • Kim, S.Y.;Lee, J.B.;Kwon, B.G.;Hong, G.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.14-18
    • /
    • 2014
  • The mechanical, electrical and thermal characteristics of insulating materials may significantly affect the performance and reliability of electrical devices using superconductors. General method to provide insulating layer between coated conductors is wrapping coated conductor with Kapton tape. But uniform and compact wrapping without failure or delamination in whole coverage for long length conductor is not a simple task and need careful control. Coating of insulating layer directly on coated conductor is desirable for providing compact insulating layer rather than wrapping insulating layers around conductor. Ceramic added polymer has been widely used as an insulating material for electric machine because of its good electrical insulating properties as well as excellent heat resistance and fairy good mechanical properties. The insulating layer of coated conductor should have high breakdown voltage and possesses suitable mechanical strength and maintain adhesiveness at the cryogenic temperature where it is used and withstand stress from thermal cycling. The insulating and mechanical properties of polymer can be improved by adding functional filler. In this study, insulating layer has been made by adding ceramic particles such as $SiO_2$ to a polymer resin. The size, amount and morphology of added ceramic powder was controlled and their effect on dielectric property of the final composite was measured and discussed for optimum composite fabrication.

Evaluation System of the Thermal Properties of the Exothermic & Insulating Materials (발열 보온재의 특성평가 시스템 구축)

  • Shin, D.Y.;Kim, D.J.;Jun, B.H.;You, B.D.;Kim, N.S.;Oh, S.H.
    • Transactions of Materials Processing
    • /
    • v.17 no.5
    • /
    • pp.356-363
    • /
    • 2008
  • An evaluation system of the thermal properties of exothermic & insulating materials was developed. By measuring the power supply of the induction furnace, the thermal property of exothermic & insulating materials could be evaluated with high reproducibility at elevated temperature of molten steel. The thermal properties of exothermic & insulating materials were affected by mixing condition of raw materials. The effect of main components of exothermic & insulating materials such as metallic aluminum and $Fe_2O_3$ powder on the exothermic and insulating properties was examined. It could be expected to design and develop various exothermic & insulating materials by means of the evaluation system of the thermal properties.

A Fundamental Study on the Effectiveness of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집에 의한 한중콘크리트 시공의 효율화에 관한 기초적 연구)

  • Kim, Kyoung-Min;Won, Cheol;Kim, Gi-Cheol;Oh, Sun-Kyo;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.617-622
    • /
    • 2001
  • This paper presents the effectiveness of cold weather concreting by applying both anti-freeze agent and insulating forms developed through previous study investigating insulating effects on the concrete and the strength gain. According to test results, in $-10^{\circ}C$ of air temperature, when euroforms are applied, the temperature of plain concrete drops below $0^{\circ}C$ and maintains its temperature during early 24 hours. However, when insulating forms are applied, the temperature of concrete keeps 8~$13^{\circ}C$ during first 24 hours. Insulating forms has better performance on insulating effects than existing euroforms. Concrete containing anti-freeze agent shows temperature rising effects about $1^{\circ}C$ compared to plain concrete. Strength gain of core concrete shows higher when insulating forms is applied.

  • PDF

Manufacturing technology of two-layer self bonding insulating tape (이중절연 자기융착테이프 제조기술)

  • 조용석;이철호;심대섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.890-893
    • /
    • 2001
  • Two-layer self bonding insulating tape consists of butyl rubber(IIR ; Isobutylene-isoprene rubber) adhesive layer and polyethylene protective film. Butyl rubber have inherent characteristics such as resistance to corrosion and water, low temperature flexibility, excellent electrical insulating properties also resistance to environmental effect such as ozone and ultraviolet. Polyethylene film was used for the purpose of good insulating properties and resistance to ozone and ultraviolet. The tape was manufactured using extrusion and calender method.

  • PDF

A study on the improvement of the thermal expansion formula of the insulating oil in electric facilities (전력설비 절연유 열팽창 계산식 개선에 관한 연구)

  • Rim, Seong-Hwang;Moon, Bong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.153-156
    • /
    • 2001
  • The transformer and the OF cable are cooled and insulated by insulating oils in their body. The insulating oil expands or contracts with the heat transfer according to the operating conditions of the electric facilities. So we install the $N_2$ gas tank connected with the insulating oil system to overcome the change. The change of the insulating oil volume for the operation temperature range must be calculated to decide the $N_2$ gas volume and to set the alarm point for safe operation. It is known that this change is proportional to the temperature change and to the insulating oil volume if the temperature change is small enough.[1][11] However this proportional formula has been accepted generally in the design of electric facilities for wide operation temperature range such as $40^{\circ}C{\sim}125^{\circ}C$. Hence, it makes large errors in calculation which car result in serious damage against safe operation of the electric facilities. This paper presents a improved method of calculating the accurate change of the insulating oil volume to insure the safe operation of electric facilities.

  • PDF

Evaluation for Argon gas-filled Insulating glass units (아르곤가스 주입 단열 복층유리 내구성 평가)

  • Kim, Kyung-Nam;Jung, Jin-Young;Bae, Ki-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.128-131
    • /
    • 2013
  • Energy losses through windows and doors are big problems in the construction industry. For glass only, it has takes the largest portion of mass from window assembly and it responsible for 24 ~ 45% of energy loss from total building energy loss. Insulating glass unit should maintain their basic functions during their working life in order to contribute positively for global warming issue. There have been many research works for improving insulating glass unit durability. But it is not easy job to fulfill the requirements because insulating glass units composed of many components. So, overall it is required to have right qualify control procedures starting from material selection to fabrication, shipping and installation to the customer site. In this report, we have reviewed the durability of insulating glass unit made from different grades of sealing materials based on globally accepted industry codes such as EN1279. ASTM E 2190 and Locally available code. KS L 2003. The result showed that there is a relationship between the mechanical properties of insulating glass 2nd sealant and the durability of the units.

  • PDF