Detection of Partial Discharge in $SF_6$ Gas-insulated Switchgear Using External UHF PD sensors (가스절연기기에서 외장형 PD 센서를 이용한 부분방전 검출)

  • Lee, Chang-R.;Hong, C.Y.;Choi, B.H.;Yoon, J.H.;Nam, G.C.;Jung, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.125-127
    • /
    • 2004
  • We have developed the external-type PD sensors for detecting of the ultra high frequency (UHF) signals in various type of GIS. Sufficiently high sensitivity and accuracy for practical use were achieved for the PD sensor. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

Seismic Response Spectrum Analysis of Gas Insulated Switchgear for 765kV Substation (765kV 가스절연 개폐장치의 지진응답스펙트럼 해석)

  • Hwang, Kyeong-Min;Jang, Jung-Bum;Kim, Jeong-Kim;Suh, Yong-Pyo;Lee, Guen-Jig
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.347-348
    • /
    • 2007
  • 최근 한반도 및 그 주변에 중소규모 이상의 지진이 빈번히 발생하고 있으나, 국내 대부분의 변전설비들은 내진설계개념을 적용하지 못하고 있는 실정이다. 특히 765kV 변전설비는 산업적, 경제적으로 중요한 국가설비이므로 전력공급 중단을 막기 위해 내진성능확보가 필수적이다. 따라서, 본 연구에서는 765kV 변전소 내 대표설비인 가스절연 개폐장치를 대상으로 내진성능평가를 수행하였으며, 그 결과 지진에 일부 취약한 부위가 발견되어 내진성능개선을 위한 보강이 필요한 것으로 나타났다.

  • PDF

The discharge characteristics & Bubble Movement for various electrode shapes in Liquid $SF_6$ (액체 $SF_6$의 전극별 기포유동현상과 절연파괴특성)

  • Choi, Eun-Hyeok;Lim, Chang-Ho;Jang, Seung-Ho;Kim, Lee-Kook;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.252-253
    • /
    • 2007
  • In this paper the experiments of breakdown characteristics $SF_6$ liquid ($LSF_6$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery which will be studied and developed in the future.

  • PDF

AC Breakdown Analysis of Composite-Insulation by the Thickness of epoxy and the Variation of Pressure (복합절연물내 기체의 압력 및 고체의 두께변화가 AC 절연파괴에 미치는 영향 분석)

  • Jung, Hae-Eun;Kim, Byoung-Chul;Yun, Jae-Hun;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.194-195
    • /
    • 2007
  • $SF_6$ gas used widely as insulating component in electric power industry has excellent in insulation and arc extinguishing performance in gas-insulated switchgear. However, the concern about eco-friendly alternative gas is currently rising because $SF_6$ gas is one of the main greenhouse gases. In this paper, dry-air and composite-insulation (dry-air+epoxy) as the alternative technology for $SF_6$ gas insulation is studied. Under the gas pressure ranged from 0.1 to 0.6MPa, the breakdown voltage of dry-air were measured in AC electric field. The data of composite-insulation were acquired by changing the thickness of epoxy used in each composite-insulation under the same condition.

  • PDF

A study on characteristic of out-put signal according to angle and sensing position for optical current sensor for GIS (GIS용 광 CT 센서부의 위치와 각도변화에 따른 출력 특성)

  • Park, Jung-Hwan;Jee, Seung-Wook;Lee, Kwang-Sik;Kim, Min-Soo;Kim, Jung-Bae;Park, Won-Zoo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.418-421
    • /
    • 2006
  • 현재 국내 외에서 GIS(Gas Insulated Switchgear)용 광 CT(optical current transformer)가 활발히 연구 개발되고 있다. 이러한 광 CT는 전력선에 발생하는 자기장에 의해 레이저 빛의 파장 각도가 변하는 현상인 Faraday Effect를 기련 원리로 한 전류측정용 기기이다. 본 논문에서는 GIS용 광 CT 개발을 목적으로 한 기초적 연구로써 자기장이 발생하는 전력선에 장착되는 센서부가 도선을 중심으로 해서 어떻게 위치하느냐에 따른 광 CT의 출력신호를 측정하여 연구하였다.

  • PDF

Performance Evaluation of 154 kV Separable Dry Type Plug-in Connector (154 kV 건식형 지중종단접속함의 성능 평가)

  • Kim, Seok-Sou;Park, Young-Chang;Oh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.470-471
    • /
    • 2007
  • Underground connectors in 154kV for the connection between power cables and power equipments represent a greater part of power system stability and reliability. This paper presents the performance evaluation of 154kV separable dry type plug-in connector of a company in Japan for transformers and Gas Insulated Switchgear. And the possibility of the application on domestic underground line was considered.

  • PDF

Effects of Metal Particle on Dielectric Breakdown of Epoxy Insulation (금속 이물질이 에폭시 절연물의 절연파괴에 미치는 영향)

  • Jang, Yoon-Ki;Lee, Dong-Won;Kim, Jung-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.207-208
    • /
    • 2007
  • Epoxy resin insulators show a lot of advantages for electrical power apparatus. Because epoxy resin provide electrical and mechanical characteristic which is excellent, it is desirable to apply epoxy resin as a spacer and post insulation in Gas Insulated Switchgear (GIS). In this study, we have investigated the influence of surface electric field attached particle contaminated spacer surfaces under SF6 gas. Also, we performed analysis of electric field. As a result, when the particle was attached on spacer, we found out a surface electric field of characteristics.

  • PDF

Breakdown Characteristics of Imitation Air under Uniform Fields and Non-Uniform (평등/불평등 전계 하에서의 제조공기(I-Air) 절연파괴특성)

  • Lee, Chang-Uk;Lee, Chang-Hun;Choi, Eun-Hyuck;Kim, Jung-Bae;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1424-1425
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79[%] : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using niform fields(Sphere-Sphere electrode) and non-uniform fields(Needle-Plane electrode) and studied relations breakdown voltage ($V_B$) by each P different d.

  • PDF

UHF-Sensor with coaxial cable balun for Diagnosis of Insulator (GIS 부분방전 측정용 동축형 밸런 부착 다이폴 UHF 내장형 센서)

  • Park, Eun-Jung;Cho, Jun-Ho;Kim, Kyung-Bong;Kim, Ki-Chai;Kim, Jung-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1457-1458
    • /
    • 2007
  • 본 논문은 전기에너지의 안정적인 공급을 위한 가스절연개폐장치(Gas Insulated Switchgear; GIS)의 안정성과 신뢰성을 확립하기 위해 GIS 내부 결함에 의한 사고의 발생을 미리 진단하는 절연진단용 UHF 대역($0.5\;{\sim}\;1.5$ GHz) 동축형 밸런 부착 안테나를 제안하였다. 동축형 밸런이 부착된 안테나를 GIS에 장착하였을 때 반사계수의 주파수특성을 실험치와 비교 검토하였다.

  • PDF

Construction of 154kV Intelligent Substation for Verification Test (154kV급 실증시험용 인텔리전트 변전소 구축)

  • Chung, Y.H.;Kim, J.B.;Lee, H.S.;Choi, I.H.;Lee, D.I
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.661-662
    • /
    • 2007
  • We have carried out the construction of the 154kV intelligent substation with KEPRI. The intelligent substation is built in Gochang testing facility of KEPCO and consists of electronic instruments for GIS(gas insulated switchgear), digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are introduced compared with the instrument transformer of conventional type. Digital control panel(DCP) replaces the LCP(local control panel) which is drived for mechanical operation. For the monitoring of the condition of GIS and TR, various sensors are used. In this paper, we mention the synopsis and report the progress state of project.

  • PDF