• 제목/요약/키워드: Instrumented pile

검색결과 59건 처리시간 0.02초

건물 침하방지를 위한 Underpinning 사례연구 (A Case Study of Underpinning for Building Settlement Reduction)

  • 박병기;이인모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.57-62
    • /
    • 1993
  • Settlements of maximum 23cm have occurred in and Apartment building consturcted on a fill layer with pile foundations. The main reason of the settlements was due to the negative skin friction applied to the pile, and settlement of adjacent ground since most pile tips are acted as a floating foundation founded on the stratum where the SPT N value was mostly less than 30. To underpin this building, the Jumbo Special Pile grouging was adopted, and instrumented data showed little differential settlement after the JSP underpinning.

  • PDF

시험 콘크리트 말뚝의 지지력 거동 (Carrying Capacity Behavior of Instrumented PC Piles)

  • 이영남;이종섭
    • 한국지반공학회지:지반
    • /
    • 제14권5호
    • /
    • pp.163-172
    • /
    • 1998
  • 말뚝의 지지력 거동을 연구하기 위하여 말뚝 제작시 다수의 변형률계를 설치한 2본의 말뚝들에 대하여 항타시에 그리고 항타후 소정의 시간이 경과된 시점에 동재하시험과 정재하시험을 몇 차례 수행하였다. 콘관입저항값 그리고 표준관입저항값과 말뚝의 단위 주면마찰력과의 관계를 규명하기 위해 재하시험전에 시험지반에 대하여 론관입시험과 표준관입시험도 실시하였다. 지지력과 두부침하량 관계를 살펴보면, 0.055D(D: 직경)의 두부침하량에서 전체지지력이 극한에 도달하였고, 이 때에 주면마찰력은 극한간에 도달했으나, 선단지지력은 계속 증가하는 것으로 나타났다. 말뚝의 지지력은 항타후 시간이 경과함에 따라 자연대수함수로 증가하였으며, 지지력 성분중 주면마찰력 성분이 항타한 후 40일 경과한 시점에 초기값의 4.6배 정도로 현저하게 증가하였다. 지지력 거동에 대한 시간경과의 영향을 보면, 시험말뚝들은 초기항타시에는 선단지지말뚝으로 거동하다가 시간이 경과하면서 주면마찰 말뚝으로 거동이 변화되었음을 관찰할 수 있었다. 단위 주면마찰력은, 토질분류에 따라 다르지만, 콘관입저항칼(q.)과 표준관입저항값(N)과 일정한 관계를 갖는 것으로 나타났으며, 관계상수는 현재 국내에서 사용하고 있는 간보다 큰 것으로 나타났다.

  • PDF

PMT결과를 이용한 말뚝의 연직 및 수평지지력 산정 사례 연구 (Case study on the prediction of vertical and horizontal pile capacity using pressuremter test results)

  • 김동철;최용규;정성기;정창규;이광욱
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.431-438
    • /
    • 1999
  • Vertical congressive and horizontal pile load tests were performed to a instrumented large diameter (D : 1,000 mm) drilled shaft. A drilled shaft was penetrated into the weathered soil and weathered rock. PMT was done for evaluation of properties for these strata. It was expected to be difficult to get undisturbed samples of weathered soils and rocks. Thus. PMT was done at the several selected depths. In those strata, to prevent the test bore hole from collapsing, bentonite slurry was used for making the test bore hole. In this study. soil properties was evaluated by means of PMT results and estimating method (direct method, the Memard method) of vertical pile capacity and horizontal pile behaviors were summarized. Also, vertical and horizontal pile capacity were calculated using PMT and pile load test results.

  • PDF

폐색정도를 고려한 개단말뚝의 지지력 산정 (Estimation of Bearing Capacity for Open-Ended Pile Considering Soil Plugging)

  • 백규호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.397-404
    • /
    • 2002
  • The bearing capacity of open-ended piles is affected by the degree of soil plugging, which is quantified by the IFR. There is not at present a design criterion for open-ended piles that explicitly considers the effect of IFR on pile load capacity In order to investigate this effect, model pile load tests using a calibration chamber were conducted on instrumented open-ended piles. The results of these tests show that the IFR increases with increasing relative density and increasing horizontal stress of soils. The unit base and shaft resistances decrease with increasing IFR. Based on the results of the model pile tests, new empirical relations for base load capacity and shaft load capacity of open-ended piles are proposed. In order to check the accuracy of predictions made with the proposed equations, the equations were applied to the full-scale pile load test preformed in this study, Based on the comparisons with the pile load test results, the proposed equations appear to produce satisfactory predictions.

  • PDF

대형 바렛말뚝과 현장타설말뚝의 하중전이특성 파악을 위한 재하시험 (Pile Load test on a Large Barrette Pile and a Bored Pile for the Identification of the Load Transfer Characteristics)

  • 한성길;박종관
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.493-498
    • /
    • 2006
  • In this study, two large pile load tests were performed in the deep sand gravel deposit of Nakdong river basin so that the characteristics of the load transfer was identified. The fully instrumented rectangular barrette pile in the size of $1.5\times3.0m$ and the circular bored pile of the diameter 1.5 m were placed into the ground below 50 m. Under the applied loads of 2,400 tonf and 4,000 tonf, the test results of the load transfer showed the portion of 83% and 93% of the applied loads on the barrette pile and the bored pile, respectively, were supported by the skin friction along the pile shaft. It was revealed that the most of these skin friction mobilized in sand layer underlying clay layer having N-value more than 30 and that the friction per unit area of the bored pile was larger than the friction of barrette pile. However, if embedded in the stiff sand graval layer, the both piles were proven to be sufficient for using as the friction piles.

Polymer Base Bored Pile in Bangkok Subsoils

  • Teparaksa, Wanchai
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.407-426
    • /
    • 2008
  • The bentonite slurry has been used as the stabilize suspension for wet process bored pile construction in Thailand. The bentonite suspension has benefit on filtration in the sand layer, but it creates thick cake film along pile shaft and loose sedimentation at pile toe. The base grouting technique was widely used to rectify the soft base or loose sedimentation problem of bored pile. The base grouting technique was not increased only end bearing capacity, but was also more increase in skin friction capacity of the bored piles. The comprehensive researches on base grouting was carried out by installing PVC casing inside the shaft to allow the drilling through the pile base in order to collect the soil sample below the pile tip. The polymer based slurry recently was used to replace the bentonite slurry to overcome the thick cake film along pile shaft as well as loose sedimentation at pile toe. The extent research on polymer slurry by physical model was performed to verify the real behavior of polymer. The appropriate mixing ratio of polymer was proposed. The design skin friction coefficient, $\beta$ and end bearing coefficient, Nq, for sand layer base on fully instrumented tested pile were proposed. The application on remedial of the lose capacity bored pile with large displacement in Bangladesh was proposed and discussed.

  • PDF

Physical and numerical modeling of drag load development on a model end-bearing pile

  • Shen, R.F.;Leung, C.F.;Chow, Y.K.
    • Geomechanics and Engineering
    • /
    • 제5권3호
    • /
    • pp.195-221
    • /
    • 2013
  • A centrifuge model study is carried out to investigate the behavior of pile subject to negative skin friction induced by pile installation, ground water drawdown and surcharge loading. A single end-bearing pile is examined as the induced negative skin friction would induce the most severe stress on the pile structural material as compared to friction piles. In addition, the behavior of the pile under simultaneous negative skin friction and dead/live loads is examined. To facilitate detailed interpretations of the test results, the model setup is extensively instrumented and involves elaborate test control schemes. To further examine the phenomenon of negative skin friction on an end-bearing pile, finite element analyses were conducted. The numerical analysis is first validated against the centrifuge test data and subsequently extended to examine the effects of pile slenderness ratio, surcharge intensity and pile-soil stiffness ratio on the degree of mobilization of negative skin friction induced on the pile. Finally experimental and numerical studies are conducted to examine the effect of applied transient live load on pile subject to negative skin friction.

압입경도 측정을 위한 표면변형 분석기법 비교 (Analytical Approaches of Surface-Local Deformations for the Measurement of Indentation Hardness)

  • 이윤희;김국환;남승훈;권동일
    • 대한금속재료학회지
    • /
    • 제47권7호
    • /
    • pp.416-422
    • /
    • 2009
  • Approaches for analyzing indentation hardness are still controversial, although the instrumented indentation technique has been generalized as one powerful method that can record surface deformation behaviors. Material pile-ups around the indenter/surface contact region make the conventional Oliver and Pharr's analysis on the instrumented indentation curve inaccurate. Thus, in order to prove the validity of the hardness analyses, five approaches were applied to the experimental data obtained from fused quartz and (100) monocrystalline tungsten specimens; an elastic recovery analysis on instrumented indentation curves, three indentation work analyses on the unit plastic volume, and a differentiation analysis on remnant indentation morphologies were tried. Five kinds of indentation hardness overlapped on one result plot showed the validity of each analysis. The modified indentation work approach based on a new definition of plastic volume showed consistent results with those from the Oliver-Pharr's and image differentiation methods. In the case of pile-up accompanying deformation, the Oliver-Pharr's and image differentiation methods showed the upper and lower limits of indentation hardness, respectively.

항타강관말뚝의 주면마찰저항 특성에 관한 현장실험 연구 (A Field Test Study on Skin Friction Behavior of Driven Steel Piles)

  • 이민희;이충숙;정창규;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.575-582
    • /
    • 2005
  • Static pile load tests for three instrumented driven steel pipe pies were performed. Based on the distributions of pile axial loads along the pile depth, Characteristics of unit skin friction were analyzed.

  • PDF

반복수평재하시험을 통한 단일형현장타설말뚝의 거동분석 (Analysis of Horizontal Behavior of a Single Column/Shaft by Horizontal Two-way Pile Load Test)

  • 정상섬;송성욱;김병철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1132-1143
    • /
    • 2008
  • A single Column/Shaft which extended the pile to the column of the bridge with same diameter has better safety and economical profit, but it usually has larger lateral displacement due to lateral loads such as wind, earthquake, wave, etc. A series of horizontal pile load testing were performed to study the lateral behavior of single column/shaft with varying different free lengths and embedded pile lengths. Eight instrumented test piles were cast-in-placed by bonding strain gauges at certain locations on both faces of the pile to measure bending moment, from two-way loadings. Linear variable differential transformers(LVDTs) were installed to measure the lateral pile displacement. Based on this, it is found that the test single column/shaft with different free lengths shows different failure modes. If the test pile has a longer free length, the failure occurs at the near the ground surface, but the shorter one's failure occurs at the below the ground surface.

  • PDF