• Title/Summary/Keyword: Instrument Error

Search Result 277, Processing Time 0.025 seconds

Performance Appraisal and Job Rotation of the Nurse In a General Hospital (간호사 인사관리 제도에 관한 연구)

  • Kwon, Young-Hee;Lee, Myung-Ha
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.3
    • /
    • pp.425-444
    • /
    • 1999
  • The purpose of this study is to survey evaluation of the nurse on the current Performance Appraisal System. the need for future performance of the nurse and the opinions about the job rotation, and suggest the direction of improvement by obtaining basic data to improve personnel management of the nurse in a hosipial, the subject of the investigation. The study was conducted self-reporting questionniare survey of 330 nurses working at C hospital located in Chonbuk Province and the data was collected from May 4. 1999 through May 14. The research used measuring instrument developed by researcher for evalution about the present performance appraisal. the need for the future performanc appraisal system and the opinion of job rotaion. The analysis of the collected data was computerized using SPSS/PC+ program, calculated frequency, percentage, the mean and standard deviation and used Pearson, s Correlation Coefficients, t-test, chi- square test. Major findings are as follows. 1) As for the purpose of the current performanc appraisal, the appraiser recognized it as a security of promotion standard, while the employee saw it as a means for control as guidance and supervison of work. 2) With regard to use the result of the present performance appraisal, appraiser picked ambiguous appraisal standard, employees recognized unilateral evaluation of superior eliminated the participation of them as the highest priority. 3) In relation to the current criteria for promotion of the nurse, both appraisers and employees placed more weight on the length of clinical than performance appraisal score. 4) There is much possibility of the appraiser making an error to evaluate considering the length of performance appraisal. 5) Both appraisers and employees indicated that prospective result of performance appraisal should be used for the ability development & motivation of the individual. 6) Concerning employee's participation for performance appraisal both sides wanted by far more participation. 7) Regarding the most ideal appraisal method, both parties favored most the way added up the evaluation of the head nurse and peer review and followed by the manner the revaluation of the head nurse by considering self-evaluation. 8) As to the individual interview after the appraisal, more than 60% of appraisers responded it's not necessary, while above 88.5% of employees answered it is essential so that it is showed significantly difference between the appraisers and the employees. 9) As far as open of the evaluation result is concerned. 75% of the appraiser were against it but 80% of the employee were for it so that it showed significantly between them. The most principal reason that the employee want is that it motivates the individual's ability development and the fairness of the appraisal increases. 10) Whether the periodical rotation is necessary or not, 80% of appraisers and employees answered it's necessary, however, over 70% of them did not want the rotation. 11) Work-group Cohesiveness level within the nursing unit was attentive different from desire of the rotation, that is, the work group cohesiveness level of nurses wanting rotation was significantly lower than that of the group not desiring it.

  • PDF

A Study on the Stand Volume Estimation by Strand Method (Strand법(法)에 의한 임분재적추정(林分材積推定)에 관(關)한 연구(硏究))

  • Lee, Heung Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.2
    • /
    • pp.187-192
    • /
    • 1991
  • This study was carried out to estimate the stand volume for Japanese larch(Larix leptolepis) by Strand sampling method. The data collected for this study were based on the 380 sample plots from the field survey, which were distributed in the major part of Korea(Kyeongi, Kangweon, Chungbuk, Chungnam, Chunbuk and Kyeongbuki), and the plotless sampling instrument such as dendrometer, spiegel relascope and tele-relascope were used. The procedure for this study is summarized briefly as follows : 1. There were not only significant differences between volume estimation by Strand sampling method and that by plot survey method, and the relationship was y=bx, where b approached nearly 1. Therefore, the stand volume of Japanese larch could by estimated by Strand sampling method. 2. The value measured by three different plotless sampling instruments did not showed any significant differences between instruments and observers, density and instruments, and ground slope and instruments. 3. With the stand volume, basal area height showed the highest correlation and stand form height, average height, basal area per ha correlated with the volume in thier orders. 4. The best fitted equation of stand volume estimation with basal area height by relascope was as follow. log V=-0.0375+0.8910 log GH-1.5946 1/GH Stand volume table also was obtained using the above estimeated equation. 5. The relationship between estimated value and actual value was Y=bx, where b was nearly 1. The correlation coefficient was very high and the percentage of estimated error was 4.5%.

  • PDF

Long-Range Transported SO2 Inflow fromAsian Continent to Korea Peninsula Using OMI SO2 Data and HYSPLIT Backward Trajectory Calculations (OMI 이산화황자료와 HYSPLIT 역궤적 계산을 이용한 동북아지역의 장거리 수송되는 이산화황 유입량 산출)

  • Park, Junsung;Hong, Hyunkee;Choi, Wonei;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.6
    • /
    • pp.743-754
    • /
    • 2014
  • In this present paper, we, for the first time, calculated $SO_2$ inflow from China to Korea peninsula based on OMI $SO_2$ products and HYSPLIT (Hybrid Single Particle Lagrangian Integrated Trajectory Model) backward trajectory calculations. The major factors used to estimate $SO_2$ flux are long range transported $SO_2$ concentration, transport speed of air mass, and thickness of transported air mass layer. The mean and maximum $SO_2$ fluxes are estimated to be 0.81 and $2.11g{\cdot}m^{-2}{\cdot}h^{-1}$, respectively based on OMI products while, those of $SO_2$ fluxes are 0.50 and $1.18g{\cdot}m^{-2}{\cdot}h^{-1}$ respectively using insitu data obtained at the surface. For most cases, larger $SO_2$ inflow values were found at the surface than those estimated for the air mass layer which extends from surface up to 1.5 km. However, increased transport speed of air mass leads to the enhanced $SO_2$ flux at the altitude up to 1.5 km at the receptor sites. Additionally, we calculate uncertainties of $SO_2$ flux using error propagation method.

Prediction of Chemical Organic Composition of Manure by Near Infrared Reflectance Spectroscopy

  • Amari, Masahiro;Fukumoto, Yasuyuki;Takada, Ryozo
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1265-1265
    • /
    • 2001
  • The organic materials included in excreta of livestock are important resources for organic manure and for improving soil quality, although there is still far from effective using. One reason for this is still unclearly standard of quality for evaluation of manure made from excreta of livestock. Therefore, the objective of this study is to develop rapid and accurate analytical method for analyzing organic compositions of manure made from excreta of livestock, and to establish quality evaluation method based on the compositions predicted by near infrared reflectance spectroscopy (NIRS). Sixteen samples of manure, each eight samples prepared from two treatments, were used in this study. The manure samples were prepared by mixing 560 kg feces of swine,60 kg sawdust with moisture content was adjusted to be 65%. The mixture was then keep under two kinds of shelter, black and clear sheets, as a treatment on the effect of sunlight. Samples were taken in every week (form week-0 to 7) during the process of manure making. Samples were analyzed to determine neutral detergent fiber (NDF), acid detergent fiber (ADF) and acid detergent lignin (ADL) by detergent methods, and organic cell wall (OCW) and fibrous content of low digestibility in OCW (Ob) by enzymatic methods. Biological oxygen demand (BOD) was analyzed by coulometric respirometer method. These compositions were carbohydrateds and lignin that were hardly digested. Spectra of samples were scanned by NIR instrument model 6500 (Pacific Scientific) and read over the range of wavelength between 400 and 2500nm. Calibration equations were developed using eight manure samples collected from black sheet shelter, while prediction was conducted to the other eight samples from clear sheet shelter. Accuracy of NTRS prediction was evaluated by correlation coefficients (r), standard error of prediction (SEP) and ration of standard deviation of reference data in prediction sample set to SEP (RPD). The r, SEP and RPD value of forage were 0.99, 0.69 and 7.6 for ADL, 0.96, 1.03 and 4.1 for NDF, 0.98, 0.60 and 4.9 for ADF, 0.92, 1.24 and 2.6 for Ob, and 0.91, 1.02 and 7.3 for BOD, respectively. The results indicated that NIRS could be used to measure the organic composition of forage used in manure samples.

  • PDF

An Analysis of the Least Observing-Session Duration of GPS for the Retrieval of Precipitable Water Vapor (GPS 가강수량 산출을 위한 최소 관측세션 지속시간에 대한 분석)

  • Kim, Yoo-Jun;Han, Sang-Ok;Kim, Ki-Hoon;Kim, Seon-Jeong;Kim, Geon-Tae;Kim, Byung-Gon
    • Atmosphere
    • /
    • v.24 no.3
    • /
    • pp.391-402
    • /
    • 2014
  • This study investigated the performances of precipitable water vapor (PWV) retrieval from the sets of ground global positioning system (GPS) signals, each of which had different length of observing-session duration, for the purpose of obtaining as short session duration as possible that is required at the least for appropriate retrieval of the PWV for meteorological usage. The shorter duration is highly desirable to make the most use of the GPS instrument on board the mobile observation vehicle making measurements place by place. First, using Bernese 5.0 software the PWV retrieval was conducted with the data sets of GPS signals archived continuously in 30 seconds interval during 2-month period of January and February, 2012 at Bukgangneung site. Each of the PWVs produced independently using different session durations was compared to that of radio-sonde launched at the same GPS location, a Bukgangneung site. Second, the same procedure was done using the data sets obtained from the mobile observation vehicle that was operating at Boseong area in Jeonnam province during Changma observation campaign in 2013, and the results were compared to that at Bukgangneung site. The results showed that as the observing-session duration increased the retrieval errors decreased with the dramatic change happening between 3 and 4 hours of the duration. On average, the root mean square error (RMSE) of the retrieved PWV was around 1 mm for the durations of greater than 4 hours. The results at both the Bukgangneung (fixed site) and Boseong (mobile vehicle) seemed to be fairly comparable with each other. From this study it is believed that at least 4 hours of observing-session duration is needed for the retrieval of PWV from the ground GPS for meteorological usage using Bernese 5.0 software.

A Study on the Reliability of Corrected Diopter according to Subjective refraction instrument (자각식굴절검사기기에 따른 교정굴절력의 신뢰도에 관한 연구)

  • Lee, Hark-Jun;Kim, Jung-Hee;Ryu, Kyung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.281-286
    • /
    • 2010
  • Purpose: This research provided basic data for refraction by comparing the corrected diopter of trial lens and phoropter. Methods: We compared the corrected diopter of trial lens and phoropter, and analyzed statistical significance and relations of the spherical lens corrected diopter and cylindrical lens corrected diopter according to the types (trial lens and phoropter) of subjective refractive instruments. Also we analyzed statistical significance and relations between cylindrical lens corrected diopter at the astigmatism and the types (trial lens and phoropter) of subjective refractory instruments. Results: When we measured the corrected diopter of simple myopia, the mean value for corrected diopter was S-2.74D using the trial lens and S-2.65D using the phoropter. So the corrected diopter was 0.09D smaller when measured by phoropter. The degree of astigmatism was measured C-0.81D using the trial lens and C-0.77D using the phoropter which showed that the measured value was 0.04D smaller using the phoropter. On correlation analysis between the refractive instruments (trial lens and phoropter) and the corrected diopter, there was significant (p<0.01) strong correlation between refractory machine and corrected spherical diopter (r=0.996) and the correlation between refractory machine and corrected cylindrical diopter was r=0.986 and was also significant (p<0.01). Conclusions: The use of phoropter than trial lens was more desirable when performing refraction on high myopia (simple refractive error, high astigmatism), and when using trial lens, you should consider the vertex distance and the gap between overlapped lenses before prescription.

Field Performance Evaluation of Candidate Samplers for National Reference Method for PM2.5 (PM2.5 국가기준측정장비 선정을 위한 비교 측정 연구)

  • Lee, Yong Hwan;Park, Jin Su;Oh, Jun;Choi, Jin Soo;Kim, Hyun Jae;Ahn, Joon Young;Hong, You Deog;Hong, Ji Hyung;Han, Jin Seok;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.157-163
    • /
    • 2015
  • To establish National Reference Method (NRM) for $PM_{2.5}$, operational performance of 5 different commercial gravimetric-based $PM_{2.5}$ measuring instruments was assessed at Bulkwang monitoring station from January 23, 2014 to February 28, 2014. First, physical properties, design, and functional performance of the instruments were assessed. Evaluation was carried out to determine whether operating method for the instruments and levels of QA/QC activities meet the data quality objectives (DQOs). To verify whether DQOs were satisfied, reproducibility of QA/QC procedures, accuracy, relative sensitivity, limit of detection, margin of error, and coefficient of determination of the instruments were also evaluated. Results of flow rate measurement of 15 candidate instruments indicated that all the instruments met performance criteria with accuracy deviation of 4.0% and reproducibility of 0.6%. Comparison of final $PM_{2.5}$ mass concentrations showed that the coefficient of determination ($R^2$) values were greater than or equal to 0.9995, and concentration gradient ranged from 0.97 to 1.03. All the instruments satisfied criteria for NRM with the estimated precision of 1.47~2.60%, accuracy of -1.90~3.00%, and absolute accuracy of 1.02~3.12%. This study found that one particular type of measuring instrument was proved to be excellent, with overall evaluation criteria satisfied.

A STUDY OF THE DEVELOPMENT AND STANDARDIZATION OF ADHD DIAGNOSTIC SYSTEM (전산화된 주의력장애 진단시스템의 개발 및 표준화 연구)

  • Cho, Sung-Zoon;Chun, Sun-Young;Hong, Kang-E;Shin, Min-Sup
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.11 no.1
    • /
    • pp.91-99
    • /
    • 2000
  • Objectives:Present study developed the computerized ADHD Diagnostic System(ADS) in order to diagnose ADHD and evaluate treatment effect of it, and conducted a standardization study for ADS. Methods:The normative group was composed of 847 children and adolescents between the age of 5 and 15(boy 429, girl 418) living in the areas of Seoul, Kyunggi-do, and Kangwon-do. 30 ADHD children with age ranged 7 to 9 years were participated present study to evaluate the validity of ADS. To establish the norms for diagnosing ADHD, the means and standard deviations of normative group were used to calculate T-scores for each age group. Results:The reliability coefficient of ADS(Cronbach's ${\alpha}$) was .85. There were significant differences in the measures of ADS except commission error between the normal and the ADHD groups. Three factors were extracted through factor analysis of ADS, which were labelled 'inattention', 'slow information processing' and 'impulsivity'. Discriminant analysis showed that ADS significantly discriminate the normal and the ADHD groups. Percentage of correct classification by ADS variables was 96.7%. Conclusion:These results put together strongly support the reliability and validity of ADS as a diagnostic instrument for ADHD.

  • PDF

Distance Measurement of Small Moving Object using Infrared Stereo Camera (적외선 스테레오 카메라를 이용한 소형 이동체의 거리 측정)

  • Oh, Jun-Ho;Lee, Sang-Hwa;Lee, Boo-Hwan;Park, Jong-Il
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • This paper proposes a real-time distance measurement system of high temperature and high speed target using infrared stereo camera. We construct an infrared stereo camera system that measure the difference between target and background temperatures for automatic target measurement. First, the proposed method detects target region based on target motion and intensity variation of local region using difference between target and background temperatures. Second, stereo matching by left and right target information is used to estimate disparity about real-time distance of target. In the proposed method using infrared stereo camera system, we compare distances in three dimension trajectory measuring instrument and in infrared stereo camera measurement. In this experiment from three video data, the result shows an average 9.68% distance error rate. The proposed method is suitable for distance and position measurement of varied targets using infrared stereo system.

A Study on Reliability and Training of Face-Bow Transfer Procedure (안궁의 신뢰성과 학습효과에 관한 연구)

  • So, Woong-Seup;Choi, Dae-Kyun;Kwon, Kung-Rock;Lee, Seok-Hyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.297-308
    • /
    • 2003
  • Face-bow is used to transfer models to the articulator in diagnosing the patient or treating problems associated with occlusion. However, there have been few reports on the reliability of the face-bow procedure and the relationship between the experience of the operator and the reliability of the face-bow procedure. The purposes of this study are to examine the reliability of the face-bow procedure and to evaluate whether the face-bow transferring has any training effect. Nine dentists working at M hospital conducted a face-bow transfer in one patient having a normal dentition and interdental relationship. The procedure was done two times a week for four weeks. The maxillary model was mounted to the articulator every time, then the landmarks on the maxillary right first molar, the maxillary left central incisor, and the maxillary left first molar were measured with a special three-dimensional instrument. These data were input into a computer, and evaluated statistically. The results were as follows ; 1. When examined with ANOVA test, the results were p=0.2040 in maxillary right first molar, p=0.0578 in maxillary left incisor, and p=0.1433 in maxillary left first molar. There was no significant(0< $p{\leq}0.05$). 2. Training 1) The correlation coefficient between trial and rejection was -0.578 when analyzed with T-distribution. The more we tried, the less errors we found. 2) When the S.D. of the first three trials was compared to the S.D. of the last three trials in face-bow transfer, the results showed that the former was larger than the latter in thirty-nine times, and the latter was larger than the former in fifteen times. The more we tried face-bow transfer, the less errors we found. 3. When the S.D. of x, y, z coordinates were examined, the S.D. of x coordinates had the largest measurement in five times, the S.D. of y coordinates had the largest measurement in four times, and the S.D. of z coordinates had the largest measurement in nine times. The possibility which the error can occur in z coordinate was the highest.