• Title/Summary/Keyword: Instantaneous Loss

Search Result 82, Processing Time 0.024 seconds

Diagnosis Method of PV Module Mismatch using Voltage and Current Waveforms (태양광 모듈의 전압 및 전류 파형을 이용한 부정합 진단 기법)

  • Ahn, Hee-Wook;Park, Gi-Yob
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.17-22
    • /
    • 2011
  • Techniques for mismatch loss minimization to increase the PV system efficiency are under development recently. In this paper, a method to make diagnosis of PV module mismatch is presented, which uses a concept of operating point factor. The method is based on the fact that the ratio of the incremental conductance of a PV module to instantaneous conductance is 1 when the module is operating at its maximum power point. The variations of module voltage and current are taking place by the maximum power point tracker in the power conditioning units of PV system. The effectiveness of the method is verified through an application to a real PV system.

Maximum Efficiency Control of an Induction Motor Drive by Parameter Adaptive Compensation (파라미터 적응보상에 의한 유도전동기의 최대효율 제어기법)

  • Shon, Jin-Geun;Choi, Myung-Gyu;Park, Jong-Chan;Na, Chae-Dong;Lee, Sung-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.162-166
    • /
    • 2000
  • In this paper, a maximum efficiency control technique of real-time processing in which parameter variation is compensated in vector control of an induction motors(I.M.) is proposed. Based on equivalent model of I.M., a loss minimization factor(LMF) with the variations of speed is derived. To solve problem of inaccuracy of LMF curves due to machine parameter variation, rotor resistance estimation is performed by using instantaneous reactive power. The estimated rotor resistance values are applied to the maximum efficiency control with a LMF.

  • PDF

A Novel Instantaneous Torque Control Scheme of Brushless Permanent Magnet Motor (브러시리스 영구자석 전동기의 새로운 순시토오크 제어 방법)

  • 최근국;박한웅;박성준;원태현;송달섭;이만형
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.7
    • /
    • pp.862-867
    • /
    • 1999
  • In general, the realization of high performance brushless permanent magnet motors which are widely used in servo drive is focused on the linear control for ripple-free torque. This is also the main problem that should be solved in all AC motors including induction motor to achieve high performance control, and recent papers deal with this problem. In this paper, the novel optimal excitation scheme of brushless permanent magnet motor producing loss-minimized ripple-free torque based on the d-q-0 reference frame is presented including 3 phase unbalanced condition. The optimized phase current waveforms that are obtained by the proposed method can be a reference values and the motor winding currents are forced to track it by delta modulation technique. As a results, it can be shown that the proposed work can minimize the torque ripple by the optimal excitation current for brushless permanent magnet motor with any arbitrary phase back EMF waveform. Simulation and experimental results prove the validity and practical applications of the proposed control scheme.

  • PDF

COMBUSTION CHARACTERISTICS AND HEAT FLUX DISTRIBUTION OF PREMIXED PROPANE MIXTURE IN A CONSTANT VOLUME COMBUSTION CHAMBER

  • PARK K. S.
    • International Journal of Automotive Technology
    • /
    • v.6 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • This work is to investigate the surface heat flux and combustion characteristics of premixed propane mixture in a constant volume chamber. The experiment of heat flux and combustion characteristics of premixed propane mixture are performed with various equivalence ratio and initial pressure conditions. Based on the experimental results, it is found that the maximum instantaneous temperature is increased with the increase of initial pressure in the chamber. There are significant differences in the burning velocity of premixed propane mixture at different measuring points in the constant volume combustion chamber. A]so, the trends of temperature difference at each measuring points are similar to the burning velocity in the combustion chamber. It is concluded that the total heat loss during the combustion period is affected by the equivalence ratio and the initial condition of fuel-air mixture.

Contribution of production and loss terms of fission products on in-containment activity under severe accident condition for VVER-1000

  • Jafarikia, S.;Feghhi, S.A.H.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.125-137
    • /
    • 2019
  • The purpose of this paper is to study the source term behavior after severe accidents by using a semi-kinetic model for simulation and calculation of in-containment activity. The reactor containment specification and the safety features of the containment under different accident conditions play a great role in evaluating the in-containment activity. Assuming in-vessel and instantaneous release of radioactivity into the containment, the behavior of in-containment isotopic activity is studied for noble gasses (Kr and Xe) and the more volatile elements of iodine, cesium, and aerosols such as Te, Rb and Sr as illustrative examples of source term release under LOCA conditions. The results of the activity removal mechanisms indicates that the impact of volumetric leakage rate for noble gasses is important during the accident, while the influence of deposition on the containment surfaces for cesium, mainly iodine isotopes and aerosol has the largest contribution in removal of activity during evolution of the accident.

Instability Analysis of Counterflow Diffusion Flames with Radiation Heat Loss (복사 열손실을 받는 대향류 확산화염의 불안정성 해석)

  • Lee, Su-Ryong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.857-864
    • /
    • 2012
  • A linear stability analysis of a diffusion flame with radiation heat loss is performed to identify linearly unstable conditions for the Damk$\ddot{o}$hler number and radiation intensity. We adopt a counterflow diffusion flame with unity Lewis number as a model. Near the kinetic limit extinction regime, the growth rates of disturbances always have real eigenvalues, and a neutral stability condition perfectly falls into the quasi-steady extinction. However, near the radiative limit extinction regime, the eigenvalues are complex, which implies pulsating instability. A stable limit cycle occurs when the temperatures of the pulsating flame exceed the maximum temperature of the steady-state flame with real positive eigenvalues. If the instantaneous temperature of the pulsating flame is below the maximum temperature, the flame cannot recover and goes to extinction. The neutral stability curve of the radiation-induced instability is plotted over a broad range of radiation intensities.

Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm (펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.111-116
    • /
    • 2022
  • The causes of motor burnout include overload, phase loss, restraint, interlayer short circuit, winding ground fault, instantaneous overvoltage, and the rotor contacting the stator, leading to insulation breakdown, leading to breakdown or electrical accidents. Therefore, equipment failure causes not only loss due to cost required for equipment maintenance/repair, but also huge economic loss due to productivity decrease due to process stop because the process itself including the motor is stopped. The current level of technology for diagnosing motor failures uses vibration, heat, and power analysis methods, but there is a limit to analyzing the problems only after a considerable amount of time has passed according to the failure. Therefore, in this paper, a device and algorithm for measuring insulation resistance using DC AMP signal was applied to an industrial motor to solve this problem. And by following the insulation resistance state value, we propose a diagnosis of deterioration and failure of the motor that cannot be solved by the existing method.

Simple assessment of wind erosion depending on the soil texture and threshold wind velocity in reclaimed tidal flat land

  • Kyo-Suk, Lee;IL-Hwan, Seo;Jae-Eui, Yang;Sang-Phil, Lee;Hyun-Gyu, Jung;Doug Young, Chung
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.843-853
    • /
    • 2021
  • The objectives of this paper were to simply estimate soil loss levels as caused by wind in reclaimed tidal flat land (RTFL) and the threshold wind velocity in the RTFL. For this experiment, RTFL located at Haenam Bay was selected and a total of 150 soil samples were collected at the Ap horizon from the five soil series. The particle distribution curves, including the limit of the non-erodible particle size (D > 0.84 mm) for each Ap horizon soil, show that the proportions of non-erodible particle sizes that exceeded 0.84 mm were 4.3% (Taehan, TH), 8.9% (Geangpo, GP), 0.5% (Bokchun, BC), 1.6% (Poseung, PS) and 1.4% (Junbook, JB), indicating that the amount of non-erodible soil particles increased with an increase in the sand content. The average monthly, daily and instantaneous wind velocities were higher than the threshold friction velocity (TFV) calculated according to the dynamic velocity (Vd) by Bagnold, while the average monthly wind velocity was lower than those of the TFV suggested by the revised wind erosion equation (RWEQ) and wind erosion prediction system (WEPS). The susceptible proportions of erodible soil particles from the Ap horizon soil samples from each soil series could be significantly influenced by the proportion of sand particles between 0.025 and 0.5 mm (or 0.84 mm) in diameter regardless of the threshold wind velocity. Thus, further investigations are needed to estimate more precisely soil erosion in RTFL, which shows various soil characteristics, as these estimations of soil loss in the five soil series were obtained only when considering wind velocities and soil textures.

The Analysis of Performance Limiting Factor in Small Water Treatment Plant (소규모정수장의 기능진단에 의한 성능제한 인자의 도출 및 검증 연구)

  • Ha, Eun-Jung;Oh, Jung-Woo;Kim, Jeong-Hyun;Yoon, Jang-Ken
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.240-250
    • /
    • 2000
  • In this study, DWTP Advisor developed from U.S. EPA was adapted for performance assessment in small water treatment plant and studied for improvement advice about the problem. From results of performance assessment, the ability of each major unit process meets to Peak Instantaneous Flow(PIF) as Type I (above 95% of PIF) in N WTP. But, outlet condition in the sedimentation basin are permitting the loss of solids from the basin and the lack of proper solids removal is degrading the performance in N WTP. From results of the hydraulic analysis using fluoride tracer, flow rate in sedimentation basin is rapidly more lower than upper. The Reynolds number, Re, and Froude number, Fr which are used to predict flow condition in sedimentation basin is calculated to be 3159.98 and $2.06{\times}10^{-7}$, respectively. There is possibility of occurrence of short-circuiting and turbulence. Also, the different type of effluent trough makes unstable flow in sedimentation basin and increases carry-overing of sedimented solids.

  • PDF

Implementation of the Radiation Protection Module for Electronic Equipment from Pulsed Radiation and Its Function Tests (펄스방사선에 대한 전자장비 방호용 모듈구현 및 기능시험)

  • Lee, Nam-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1421-1424
    • /
    • 2013
  • The electronic equipment which is exposed to high level pulsed radiation is damaged by Upset, Latchup, and Burnout. Those damages come from the instantaneous photocurrent from electron-hole pairs generated in itself. Such damages appear as losses of a power in military weapon system or as a blackout in aerospace equipment and eventually caused in gross loss of national power. In this paper, we have implemented a RDC(Radiation detection and control module) as a part of the radiation protection technology of the electronic equipment or devices from the pulsed gamma radiation. The RDC, which is composed of pulsed gamma-ray detection sensor, signal processors, and pulse generator, is designed to protect the an important electronic circuits from the a pulse radiation. To verify the functionality of the RDC, LM118s, which had damaged by the pulse radiation, were tested. The test results showed that the test sample applied with the RDC was worked well in spite of the irradiation of a pulse radiation. Through the experiments we could confirm that the radiation protection technology implemented with the RDC had the functionality of radiation protection for the electronic devices.