The Analysis of Performance Limiting Factor in Small Water Treatment Plant

소규모정수장의 기능진단에 의한 성능제한 인자의 도출 및 검증 연구

  • 하은정 (한국수자원공사 수자원연구소 수도연구부) ;
  • 오정우 (한국수자원공사 수자원연구소 수도연구부) ;
  • 김정현 (한국수자원공사 수자원연구소 수도연구부) ;
  • 윤장근 (한국수자원공사 수자원연구소 수도연구부)
  • Published : 2000.09.15

Abstract

In this study, DWTP Advisor developed from U.S. EPA was adapted for performance assessment in small water treatment plant and studied for improvement advice about the problem. From results of performance assessment, the ability of each major unit process meets to Peak Instantaneous Flow(PIF) as Type I (above 95% of PIF) in N WTP. But, outlet condition in the sedimentation basin are permitting the loss of solids from the basin and the lack of proper solids removal is degrading the performance in N WTP. From results of the hydraulic analysis using fluoride tracer, flow rate in sedimentation basin is rapidly more lower than upper. The Reynolds number, Re, and Froude number, Fr which are used to predict flow condition in sedimentation basin is calculated to be 3159.98 and $2.06{\times}10^{-7}$, respectively. There is possibility of occurrence of short-circuiting and turbulence. Also, the different type of effluent trough makes unstable flow in sedimentation basin and increases carry-overing of sedimented solids.

Keywords