• Title/Summary/Keyword: Installation criteria

Search Result 298, Processing Time 0.029 seconds

School Zone Safety Improvement Using Smart Bollard (Smart Bollard를 이용한 어린이보호구역에서의 안전성 제고에 관한 연구)

  • Kim, Hoe Kyoung;Lim, Jae Moon;Sul, Jae Hoon;Oh, Yun Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.251-259
    • /
    • 2013
  • This paper is aimed to introduce to a moving bollard (i.e., smart bollard) to improve the pedestrian safety along the crosswalk in the school zone as a means to physically separate pedestrians and approaching vehicles, to propose the appropriate criteria for its installation and implementation from the traffic engineering perspective, and to evaluate its effectiveness with the microscopic simulation model. The simulation results indicate that implementing the smart bollard results in the decrease of average approaching speed and traffic throughput and the most critical factors affecting its effectiveness are yellow time of the traffic signal directly associated with the location of the advance warning sign and its operation time, 5~6 seconds and 2~3 seconds, respectively.

A Study on the Effect of School Site Planning Factors Related to School Location on Increase and Decrease of the Number of Students in Korea (학교 입지 계획요소가 학생수 증감에 미치는 영향에 관한 연구)

  • Yoon, Yong-Gi
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.1
    • /
    • pp.20-29
    • /
    • 2017
  • In order to prove the hypothesis that the element of school location planning - the density of development, availability of various private institutes, the location of school, the type of school district, the distance to nearby schools, the existence of communal areas, the pedestrian street, the number of road lanes - affects the increase and decrease of the number of students in the long term, we examined the tendency of the number of long-term (24 years). The results of the analysis are as follows: First, the development factors such as development density, location of school, type of school district, distance from neighboring schools, separation of pedestrians and cars are clearly related. Second, the planning factors such as location of private school and installation of pedestrian-only street seem to be related to each other. Third, the number of road lanes and element of "communal area" is irrelevant. This study is limited to generalization of five new metropolitan cities in the metropolitan area, and it is necessary to further elaborate the analysis factors and evaluation criteria.

Field Test for Absorption Energy and Displacement of Rockfall Protection Net (낙석방지울타리 망의 변위량 및 성능검증을 위한 실물낙석시험)

  • Seo, JinHyuk;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.12
    • /
    • pp.17-21
    • /
    • 2020
  • Over 60% of South Korea's land consists of mountainous topography, and recently, due to earthquakes, localized heavy rains and road development, the risks of rockfalls are getting higher. As of now, rockfall prevention facilities are being constructed in 70% of Korean roads cut slope and rockfall protections account for about 20% of them. Rockfall protection's supporting capacity is defined by combining performance of wire mesh, pillars and wire ropes. For the existing constructed rockfall protection, standards of pillars that can absorb 48~61 kJ amount of energy, wire ropes and wire mesh are presented in Guidelines for the installation and management of traffic safety facilities, Rockfall prevention facilities by Ministry of Land, Transport and Maritime Affairs (2008). However, each factor's correlation of absorption energy is not presented so it is uncertain. This study will conduct vertical drop test and identify adequacy of rockfall protection net of displacement quantity calculation factor which is delta and evaluate rockfall protection net's absorbable energy through standards of overseas performance evaluation criteria.

A Study on the Changes of the Library's Bookshelves by the Morphological Evolution of Knowledge-Information - Focus on the History of Western Libraries before the 20th Century - (지식정보의 형태적 진화와 도서관 서가의 변천에 관한 연구 - 20세기이전의 서양도서관사를 중심으로 -)

  • Hwang, Mee-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.4
    • /
    • pp.90-98
    • /
    • 2010
  • This study intends to understand the change of the library's bookshelves shape, composition and arrangement based on the social-culture in each period. For this purpose, this study analyzes the morphological shift of the library's bookshelves and knowledge information focused on the history of western libraries from the ancient libraries to the modern public libraries before the 20th century. And the results are follows. 1) We can make sure that the changes of the library's bookshelves are based on the environmental factors like social cultural political factors and also understand that the knowledge information are developed based on the function which is decided by the needs of the times and the serious necessities of users. With this reason, the morphology and the function of the library's bookshelves have been changed. 2) The characters and meanings of the library's bookshelves are changed with the times from movable type to fixed type, from closing type to opening type, from privileged use to public use, from religious contents to general scientific contents. 3) The morphology of the library's bookshelves are shifted from cylindrical box to Chest type Press type and Lectern system, Stall system, Wall system and advanced to Mixed(Stall+Wall) system. 4) The construction and arrangement methods of the library's bookshelves are determined by the convenience and efficiency of the installation for the perusal environments as well as the regarding to the social-cultural factors. The arrangement criteria are determined by the security topics in the earlier stage, after that determined by the lightening topics and nowadays the access topics to the information. These analysis results are very useful to research the technology of the library's bookshelves to be changed continuously and also to forecast the morphology of the library's bookshelves can be planned in the spaces of the future libraries.

Comparative Study on the Subsurface Drainage Discharge Performance by the Type of Non-Excavation Subsurface Drainage Culvert (비굴착 지하배수암거 형태별 지하배수 성능 비교분석)

  • Kim, Hyuntai;Ryu, Jeonyong;Jung, Kiyuol;Seo, Donguk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.73-81
    • /
    • 2018
  • In this study, subsurface discharge performance has been studied through theoretical seepage analysis on four types of culverts that can be installed under the condition of non-excavation, such as (a)perforated pipe(${\Phi}50mm$), (b)perforated pipe+horizontal mat (B50cm) (c)perforated pipe+horizontal mat+vertical gravel(B<10cm), (d)perforated pipe+vertical gravel(B<10cm), and existing typical type (e)perforated pipe with gravel (B40, h=40cm) which can be installed by excavation. The analysis results were as follows. i) Subsurface discharge performance per unit (m) was (a)type 56%, (b) 91%, (c) 96%, (d) 76%, respectively, lower than the value of (e)culvert. ii) However, considering that non-excavation culvert can be installed at a spacing of 5m with the installation cost of the existing excavation culvert at the interval of 10m, it was analyzed that unit subsurface discharge(q) of (a)20.2mm/day(110%), (b)32.8(178%), (c)34.6(188%) (d)27.5(149%) in the four types of non-excavation culvert installed at intervals of 5m under the condition of $ k=10^{-4}cm/s$ was much larger than the amount of (e)type 18.5(100%), existing excavation culvert installed at 10m interval. iii) Through the test construction, peak subsurface drainage discharge($q_p$) was 38.4mm/day, which is larger than the value of design criteria and confirmed that it satisfies the analysis results as well. iv) In particular, it was evaluated that (b)perforated pipe+horizontal mat(B50cm) are low cost, high efficiency subsurface drainage culvert type with sufficient drainage performance(178%).

A study on the program development for optimizing the supply and exhaust port opening ratio in road tunnels with transverse ventilation system (횡류식 도로터널의 급배기구 개도율 최적화 프로그램 개발 연구)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Min, Dea-Kee;Kim, Jong-Won;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.517-532
    • /
    • 2017
  • The transverse ventilation system, commonly applied to urban tunnel, is necessary to be distributed with airflow uniformly. In this study, we developed a program that can optimize the opening ratio of ports to ensure ventilation performance of design criteria through a uniform airflow distribution even though ventilation interval becomes longer. And program's prediction performance was verified by comparison with TUNVEN DUCT program. For comparison, Semi-transverse ventilation system was applied. Both programs predicted a similar port size and air flow distribution, and the variation range of the calculated values was 11.71% and 1.36%, respectively. This program is very useful for port optimization design of transverse and semi-transverse ventilation system, because it is possible to analyze various tunnel lengths and supply/exhaust port installation conditions.

A study on the regulation of durability standard of underground structures monitoring sensors (지하구조물 계측센서의 내구연한 기준에 대한 규정 분석 연구)

  • Woo, Jong-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.73-81
    • /
    • 2018
  • The purpose of this study is to research the regulation of durability standard of underground structures monitoring sensors. The durability criteria for construction monitoring sensors of domestic construction companies, the standard years of contents such as buildings on the income tax implementation regulations, and the standards of the Public Procurement Service for construction monitoring and construction machinery were analyzed. The durability criterion on products such as the inclination meter and the strain gauge, which are purchased from the Public Procurement Service prior to installation on the underground structure, is 8 to 10 years. It is considered that the monitoring sensor installed in the paperboard and the concrete structure at the time of construction will have considerably shortened service life rather than the useful life of the product itself due to various adverse factors such as groundwater influence and compaction.

A Study on the Analysis and Direction for Revision of the Small Library Ordinance in Gyeonggi-do (경기도 작은도서관 조례 분석 및 개정방향에 관한 연구)

  • Choi, Manho;Noh, Younghee;Chang, Rosa;Kim, Yoonjeong
    • Journal of Korean Library and Information Science Society
    • /
    • v.51 no.2
    • /
    • pp.187-212
    • /
    • 2020
  • It is expected that Gyeonggi-do Small Libraries will increase in quantity in the future due to the current SOC complex project being implemented by the government, and it is deemed that institutional and policy support must be provided with priority in order for the Small Libraries to grow qualitatively through the implementation of substantial measures. Based on the findings of this study, the reform measures proposed to revitalize Gyeonggi-do Small Libraries in terms of ordinances as follows: ① strengthen the library law and business promotion related to Small Libraries; ② enact the mandatory library law provisions for the installation of and support for Small Libraries; ③ even if there are relevant provisions in the 「Library Act」, the local governments' Small Libraries Support Ordinances should at least simply state that they must meet the criteria specified in the 「Library Act」; and ④ provisions on the number and qualifications of operating personnel of Small Libraries reflecting the number of users and the size of collections of books of Small Libraries of cities and counties.

Alveolar ridge augmentation with the perforated and nonperforated bone grafts

  • de Avila, Erica Dorigatti;Filho, Jose Scarso;de Oliveira Ramalho, Lizete Toledo;Real Gabrielli, Mario Francisco;Pereira Filho, Valfrido Antonio
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.1
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose: Autogenous bones are frequently used because of their lack of antigenicity, but good osteoconductive and osteoinductive properties. This study evaluated the biological behavior of perforated and nonperforated cortical block bone grafts. Methods: Ten nonsmoking patients who required treatment due to severe resorption of the alveolar process and subsequent implant installation were included in the study. The inclusion criteria was loss of one or more teeth; the presence of atrophy of the alveolar process with the indication of reconstruction procedures to allow rehabilitation with dental implants; and the absence of systemic disease, local infection, or inflammation. The patients were randomly divided into two groups based on whether they received a perforated (inner surface) or nonperforated graft. After a 6-month healing period, a biopsy was performed and osseointegrated implants were installed in the same procedure. Results: Fibrous connective tissue was evident at the interface in patients who received nonperforated grafts. However, full union between the graft and host bed was visible in those who had received a perforated graft. Conclusions: We found that cortical inner side perforations at donor sites increased the surface area and opened the medullary cavity. Our results indicate an increased rate of graft incorporation in patients who received such perforated grafts.

Behavior of Underground Flexible Pipes Subject to Vehicle Load (ll)-Based on Field Tests- (차량하중을 받는 지중연성관의 거동특성 (ll)-실증실험을 중심으로-)

  • 이대수;상현규;김경열;홍성연
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.49-58
    • /
    • 2003
  • Underground flexible pipes for electric cables are subject to external loads and surrounding soil pressure. Particularly, strain of flexible pipes is of great concern in terms of safety and maintenance for electric cables. In this paper, stress and strain of flexible pipes with various installation depth are compared using traditional formula, FEM analysis, model soil box test and field test. from the findings of various analyses, considering the strain criteria-maximum 3.5%, it is suggested that flexible pipes can be buried at the depth of 80cm without additional soil improvement.