• 제목/요약/키워드: Inspection and monitoring system

검색결과 356건 처리시간 0.029초

공정플랜트 연료배관의 시스템응력 해석에 의한 구조 건전성 평가 (Structural Integrity Evaluation by System Stress Analysis for Fuel Piping in a Process Plant)

  • 정성용;윤기봉;팜반듀엣;유종민;김지윤
    • 한국안전학회지
    • /
    • 제28권3호
    • /
    • pp.44-50
    • /
    • 2013
  • Process gas piping is one of the most basic components frequently used in the refinery and petrochemical plants. Many kinds of by-product gas have been used as fuel in the process plants. In some plants, natural gas is additionally introduced and mixed with the byproduct gas for upgrading the fuel. In this case, safety or design margin of the changed piping system of the plant should be re-evaluated based on a proper design code such as ASME or API codes since internal pressure, temperature and gas compositions are different from the original plant design conditions. In this study, series of piping stress analysis were conducted for a process piping used for transporting the mixed gas of the by-product gas and the natural gas from a mixing drum to a knock-out drum in a refinery plant. The analysed piping section had been actually installed in a domestic industry and needed safety audit since the design condition was changed. Pipe locations of the maximum system stress and displacement were determined, which can be candidate inspection and safety monitoring points during the upcoming operation period. For studying the effects of outside air temperature to safety the additional stress analysis were conducted for various temperatures in $0{\sim}30^{\circ}C$. Effects of the friction coefficient between the pipe and support were also investigated showing a proper choice if the friction coefficient is important. The maximum system stresses were occurred mainly at elbow, tee and support locations, which shows the thermal load contributes considerably to the system stress rather than the internal pressure or the gravity loads.

비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구 (The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT)

  • 안기정
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.183-188
    • /
    • 2017
  • 최근, 감마선 조사기의 자동 원격 조사 제어기가 오동작하여 방사선작업종사자가 방사선 피폭 사고가 지속적으로 보고되고 있다. 이에 NDT 분야에서는 방사선에 대한 잠재적 사고를 미연에 방지하기 위한 방사선원 모니터링 시스템 구축에 많은 시간과 재원을 투자하고 있다. 이에 본 연구에서는 다양한 비파괴검사장비에 범용적으로 적용할 수 있는 방사선원 위치 모니터링 시스템의 개발을 위한 선행연구로써 몬테카를로 시뮬레이션을 통해 산화납 기반 방사선 검출기에 대한 감마선 응답 특성을 모의 추정하였다. 연구 결과, 방사선 검출기의 최적화 두께는 방사선원에서 방사되는 감마선 에너지에 따라 상이하며 에너지가 증가함에 따라 최적화 두께가 점차 증가하는 것으로 나타났다. 결론적으로 PbO 기반 방사선 검출기의 최적화 두께는 Ir-192에 대하여 $200{\mu}m$, Se-75 $150{\mu}m$, Co-60 $300{\mu}m$로 분석되었다. 이러한 연구 결과를 바탕으로 범용적으로 적용하기 위하여 2차 전자 평형을 고려한 PbO 기반 방사선 검출기의 적절한 두께는 $300{\mu}m$로 평가되었다. 이러한 결과는 차후 다양한 NDT 장비에 범용적으로 적용하기 위한 방사선원 위치 모니터링 시스템을 개발 시 방사선 검출기에서 요구되는 적절한 두께를 결정하는데 있어 기초자료로 활용될 수 있을 것으로 사료된다.

운용모드해석에 기반한 사장교의 장단기 동특성 평가 (Evaluation of Short and Long-Term Modal Parameters of a Cable-Stayed Bridge Based on Operational Modal Analysis)

  • 박종칠
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권4호
    • /
    • pp.20-29
    • /
    • 2022
  • 상시진동을 이용하여 구조계의 동특성을 추출하는 운용모드해석 기법은 케이블교량 구조건전성모니터링의 한 분야로써 다양한 연구와 실험적 검증이 수행되어왔다. 본 연구에서는 두 번에 걸친 상시진동실험과 함께 3년간의 장기 계측을 통해 수집된 가속도 데이터를 이용하여 공용 중인 사장교의 장단기 동특성을 평가하였다. 교량 준공 이후 6년과 19년이 경과한 시기에 실시한 고해상도 상시진동실험으로부터 0.1 ~ 2.5 Hz 대역에서 27개 수직모드(휨, 비틈)와 1개 수평모드를 추출하였다. 운용모드해석에 기반한 동특성 추출은 PP기법, ERADC기법, FDD기법, TDD기법을 적용하였으며, 적용한 기법들 간에 유의미한 차이가 없는 것을 확인하였다. 장기 계측 고유진동수와 환경 요인(온도, 바람)에 대한 상관성 분석으로부터 온도 변화가 고유진동수 변동에 지배적인 영향인자임을 확인하였다. 대상교량의 고유진동수 감소 경향은 구조성능과 일체성이 변한 것이 아니라 두 번의 상시진동실험 간 온도 차이에 의한 환경영향이 컸음을 밝혔다. 또한 TDD기법 적용 시, 지연이 0에서 자기상관이 1이 되도록 시퀀스를 정규화하는 알고리즘을 추가하여 모드형상 추출의 정확도를 개선하였다.

소화약제 누기 감시장치의 모듈개발 및 성능검증에 관한 연구 (A Study on the Development of a Fire Extinguishing Agent Leakage Monitoring Module and its Performance Assessment)

  • 손봉세;홍성호;고아라
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.43-48
    • /
    • 2016
  • 가스계소화설비는 소화약제의 자연 누기와 소화설비 노후로 인한 누기 등으로 화재진압 능력이 저하되는 문제점이 발생하고 있다. 이에 본 연구에서는 소화약제의 누기를 실시간으로 감지하는 압력누기 체크센서 모듈을 개발하였으며, 개발 모듈에 대한 성능평가를 하였다. 국내 외적으로 압력누기 감시 시스템에 대한 명확한 시험기준이 마련되어 있지 않다. 따라서 국외 유사 기준 ISO 7240, FM 1421와 국내 수신기 형식승인 및 제품검사의 기술기준을 참고하여 개발 모듈에 맞게 기본 성능과 내환경성에 대한 기준을 마련하고 평가를 실행하였다. 기본 성능 평가는 압축공기를 모듈에 인가하는 방식으로 최저작동 압력이 0.3 bar인 것을 확인하였다. 내환경성 검증은 통상적으로 발생할 수 있는 기후변화에도 오작동 없이 정상적으로 작동하는지를 확인하였다. 그 결과, 고온($50^{\circ}C$) 및 저온($-10^{\circ}C$) 환경 기준에서 이상 없이 정상 작동하였다.

학습기반 효율적인 얼굴 검출 시스템 설계 (Design of an efficient learning-based face detection system)

  • 김현식;김완태;박병준
    • 디지털산업정보학회논문지
    • /
    • 제19권3호
    • /
    • pp.213-220
    • /
    • 2023
  • Face recognition is a very important process in video monitoring and is a type of biometric technology. It is mainly used for identification and security purposes, such as ID cards, licenses, and passports. The recognition process has many variables and is complex, so development has been slow. In this paper, we proposed a face recognition method using CNN, which has been re-examined due to the recent development of computers and algorithms, and compared with the feature comparison method, which is an existing face recognition algorithm, to verify performance. The proposed face search method is divided into a face region extraction step and a learning step. For learning, face images were standardized to 50×50 pixels, and learning was conducted while minimizing unnecessary nodes. In this paper, convolution and polling-based techniques, which are one of the deep learning technologies, were used for learning, and 1,000 face images were randomly selected from among 7,000 images of Caltech, and as a result of inspection, the final recognition rate was 98%.

검체검사 관련 법제도의 문제점 및 발전방향 (Problems and Developing Directions of the Legal System Related to Laboratory medical testing)

  • 황유성;정정일
    • 의료법학
    • /
    • 제9권2호
    • /
    • pp.209-229
    • /
    • 2008
  • When we are totalizing the lawsrelated to the medical, as the Laboratory medical testing is a kind of the medical act, it is the regulation that the medical technologist can analyze the specimen using in vitro diagnostic devices and diagnosticdrugs under the guidance of doctor or dentist from a corresponding medical institution and can report through verification and interpretation. However, in real medical fields, 'the guidance of doctor' is seriously in-sufficient or even the person who is not the medical technologist is executing. Furthermore the cases that produce inspection results with devices or reagents which are not validated nor approved have been frequently occurred. The result of Laboratory medical testing derived from this procedure can become the important information for the disease control of a country, and also can be decisive to the definite diagnosis and the prognostic monitoring about the patient disease. In spite of its significant medical act to be applicable to an unique proof with the related expert appraisal result in the medical mal-practice lawsuit, our reality in which the quality control is not properly working due by the costs and the labor shortage related to the Laboratory medical testing is quietly in bad condition. Even from now, the government should recognize the significance of the Laboratory medical testing and must achieve more strict administrative management as well as the law maintenance.

  • PDF

중국(中國)의 대한(對韓) 반(反)덤핑조사(調査) 요인(要因)에 관한 실증(實證) 연구(硏究) - 철강(鐵鋼).석유화학(石油化學).제지(製紙) 산업(産業) 중심(中心) - (A study on the Reason of China's Anti-Dumping inspection against South Korea)

  • 심윤수
    • 무역상무연구
    • /
    • 제30권
    • /
    • pp.145-174
    • /
    • 2006
  • An anti-dumping has become the trade policy of choice for developing countries as well as advanced countries, hence it is the impending issue to the export-oriented countries including Korea. After colligating the analysis on the trade and industrial policy between Korea and China as well as the analysis on the preceding research, the main reasons of anti-dumping were selected as followings; an unemployment rate, real GDP growth rate and consumer price increase as internal factors, and trade balance, regional coefficient and trade specification index as external factors. Then, the research on how the above seven variable factors can affect the number of anti-dumping measures was accomplished. For the empirical analysis, the above information was used after reorganizing them by on the quarterly basis. Through the use of the correlation analysis, backward elimination of multiple regression analysis model and time-series analysis, it has appeared that the unemployment rate appeared to be the most important factors of anti-dumping measures in addition to the increase rate of trade balance. The variable such as the unemployment rate is uncontrollable for us, so it is appropriate to establish and operate an preemptive monitoring system based on the increasing rate of the amount of export and increasing rate of trade surplus.

  • PDF

수술실 간호사의 간호과오경험 후 대처가 업무 스트레스에 미치는 영향 (Effect on Coping Behavior on the Job Stress after Nursing Error Experience in the Operation Room)

  • 강경숙;이미영
    • 한국직업건강간호학회지
    • /
    • 제29권1호
    • /
    • pp.78-87
    • /
    • 2020
  • Purpose: The purpose of this study was to identify the relationship between nursing error experience, coping behavior and job stress in operating room. Methods: A descriptive research design was used in this study. The participants were 228 operating room nurses in G city who surveyed between October 25 and November 25, 2017 using self-report questionnaires. The data were analyzed using IBM SPSS/WIN 24.0/AMOS WIN 24.0 Program, which determined frequency, percentage, mean, standard deviation, Pearson correlation coefficient, and structural equation model. Results: There were significant positive correlations between six sub-categories of nursing errors and job stress. We found negative correlations between coping behavior and job stress. There was a mediating effect of active coping between knowledge of nursing error and job stress. We found passive coping between inspection & monitoring related error and job stress. Conclusion: Study findings suggest that adequate education and the improvement in hospital environment and system should be required to reduce the nurses' job stress related to the patients' safety in operating room.

Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

  • Lee, Hyun Cheol;Koo, Bon Tack;Choi, Chang Il;Park, Chang Su;Kwon, Jeongwan;Kim, Hong-Suk;Chung, Heejun;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • 제45권3호
    • /
    • pp.117-129
    • /
    • 2020
  • Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm. Materials and Methods: The algorithm was modified by increasing the energy weighting factor, and different peak combinations of the energy-weighted spectra were tested for source identification. A commercialized RPM system was used to measure the energy-weighted spectra. The RPM comprised two large plastic scintillators with dimensions of 174 × 29 × 7 ㎤ facing each other at a distance of 4.6 m. In addition, the in-house-fabricated signal processing boards were connected to collect the signal converted into a spectrum. Further, the spectra from eight radioactive sources, including special nuclear materials (SNMs), which were set in motion using a linear motion system (LMS) and a cargo truck, were estimated to identify the source identification rate. Results and Discussion: Each energy-weighted spectrum exhibited a specific peak location, although high statistical fluctuation errors could be observed in the spectrum with the increasing source speed. In particular, 137Cs and 60Co in motion were identified completely (100%) at speeds of 5 and 10 km/hr. Further, SNMs, which trigger the RPM alarm, were identified approximately 80% of the time at both the aforementioned speeds. Conclusion: Using the modified energy-weighted algorithm, several characteristics of the energy weighted spectra could be observed when the used sources were in motion and when the geometric efficiency was low. In particular, the discrimination between 60Co and 40K, which triggers false alarms at the primary inspection sites, can be improved using the proposed algorithm.

Experimental Study on Tip Clearance Effects for Performance Characteristics of Ducted Fan

  • ;최현민;조진수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.395-398
    • /
    • 2009
  • Currently, a new generation of ducted fan UAVs (Unmanned Aerial Vehicles) is under development for a wide range of inspection, investigation and combat missions as well as for a variety of civil roles like traffic monitoring, meteorological studies, hazard mitigation etc. The current study presents extensive results obtained experimentally in order to investigate the tip clearance effects on performance characteristics of a ducted fan for small UAV systems. Three ducted fans having different tip clearance gap and with same rotor size were examined under three different yawed conditions of calibrated slanted hot-wire probe. Three dimensional velocity flow fields were measured from hub to tip at outlet of the ducted fan. The analysis of data were done by PLEAT (Phase locked Ensemble Averaging Technique) and three non-linear differential equations were solved simultaneously by using Newton -Rhapson numerical method. Flow field characteristics such as tip vortex and secondary flow were confirmed through axial, radial and tangential velocity contour plots. At the same time, the effects of tip clearance on axial thrust and input power were also investigated by using wind tunnel measurement system. For enhancing the performance of ducted fan, tip clearance level should be as small as possible.

  • PDF