• 제목/요약/키워드: Inspection and monitoring system

검색결과 356건 처리시간 0.026초

드론을 이용한 태양광 발전소 고장 점검 (Detecting Fault of Solar Plant using Drone)

  • 김동균;박관남;조상윤;이영권;유권종;정문호;최익;최주엽
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.471-472
    • /
    • 2016
  • Since photovoltaic generating system is significantly important among renewable energy sources, photovoltaic plants are installed more than past. As a result, accidents of photovoltaic system are also increased, so the additional hardware which includes monitoring system and periodic inspection are required for safety. In addition, a photovoltaic system is installed where a person can't approach to detect a fault, so a number of devices are required to detect it. This paper proposes that drone and thermo-graphic camera are used for detecting a fault of photovoltaic plant and suggests efficiency to control a drone for detecting a photovoltaic plant.

  • PDF

Water loss Control in DMA Monitoring System Used Wireless Technology

  • Malithong, P.;Gulphanich, S.;Suesut, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.773-777
    • /
    • 2005
  • This article is about using information technology to apply with water loss inspection system in District Metering Area (DMA). Inspector can check Flow rate and Minimum Night Flow; NMF via Smart Phone or PDA include sending SMS Alert in case the Pressure, Flow rate and NMF is over the range of controlling. This will be used as equipment to implement water loss in international proactive and can keep on water loss reduction more efficiency. The system consists of Data Logger which collects data of Flow rate from DMA Master Meter. PC is Wap Server which dial via modem in order to get data through FTP Protocal that will convert text file to Microsoft Access Database. Wappage will use xhtml language to show database on Wapbrowser and can show the result on Smart Phone or PDA by graph and table for system analysis.

  • PDF

CURRENT STATUS OF INTEGRITY ASSESSMENT BY SIPPING SYSTEM OF SPENT FUEL BUNDLES IRRADIATED IN CANDU REACTOR

  • Park, Jong-Youl;Shim, Moon-Soo;Lee, Jong-Hyeon
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.875-882
    • /
    • 2014
  • In terms of safety and the efficient management of spent fuel storage, detecting failed fuel is one of the most important tasks in a CANada Deuterium Uranium (CANDU) reactor operation. It has been successfully demonstrated that in a CANDU reactor, on-power failed fuel detection and location systems, along with alarm area gamma monitors, can detect and locate defective and suspect fuel bundles before discharging them from the reactor to the spent fuel storage bay. In the reception bay, however, only visual inspection has been used to identify suspect bundles. Gaseous fission product and delayed neutron monitoring systems cannot precisely distinguish failed fuel elements from each fuel bundle. This study reports the use of a sipping system in a CANDU reactor for the integrity assessment of spent fuel bundles. The integrity assessment of spent fuel bundles using this sipping system has shown promise as a nondestructive test for detecting a defective fuel bundle in a CANDU reactor.

희생양극식 음극방식이 적용된 해안 교량 구조물의 방식거동 (Cathodic Protection Behavior of Coastal Bridge Structure with Sacrificial Anode Cathodic Protection System)

  • 하지명;진충국;정진아
    • Corrosion Science and Technology
    • /
    • 제11권6호
    • /
    • pp.242-246
    • /
    • 2012
  • This measurement represents the effectiveness of sacrificial anode cathodic protection (SACP) system in a coastal bridge structure. To verify the cathodic protection (CP) effect, the monitoring sensor (DMS-100) that could measure potential, corrosion rate, current, concrete resistivity, and temperature was embedded. The measurement conducted for three years after CP system was installed. Specifically, due to the fact that fresh water and sea water was repeated in the bridge structure, this bridge structure presented special CP behavior. Measurement factors were CP potential, CP current, concrete resistivity, and depolarization potential. In addition, visual inspection was also carried out. As a result of current and depolarization measurement, CP system was well activated in most piers.

예방적 유지보수 공법의 현장 적용성능 평가 연구 (Field Performance Evaluation of Preventive Maintenance Methods)

  • 이상염
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.103-112
    • /
    • 2017
  • PURPOSES : In this study, field performance evaluation of crack treatment of pavement and the feasibility of surface treatment of pavement are presented. The performance and cost of preventive maintenance methods have been previously verified, and the methods are being used in many developed countries and cities. However, the performance and cost of the system have not been verified in domestic, field applications. Therefore, in order to improve performance, the field performance is evaluated, and a reasonable cost is proposed. METHODS : Visual Inspection was conducted to evaluate the field application and performance of the preventive maintenance method. In addition, the PCI index was calculated from the results of visual inspection of the application area of the surface treatment method, and the performance life of each method was predicted. For the economic evaluation, life cycle cost analysis was performed using the life cycle cost analysis program. RESULTS :In order to evaluate and quantify the field performance of crack repair material, the residue condition of the pavement surface after crack treatment, rather than the performance of the material, is evaluated. In addition, the crack resistance and performance life of surface treatment methods are evaluated. The cost of currently available treatment methods are compared to the common pavement cut and overlay method, and it is determined that the preventive method is not economical based on life cycle cost analysis. CONCLUSIONS :Because of the characteristics of cracking, it is necessary to conduct the evaluation of currently applied methods and the analysis of the cause of damage, by visual inspection. Moreover, in order to evaluate the performance and economic suitability of the currently applied surface treatment methods, it is necessary to acquire information on application sections by monitoring their long-term conditions and performance.

해상용 항로표지 충·방전조절기의 근거리 모니터링 (Short-range Monitoring of Marine AtoN Charge and Discharge Controller)

  • 예성현;한순희
    • 한국정보통신학회논문지
    • /
    • 제19권4호
    • /
    • pp.933-939
    • /
    • 2015
  • 일반전원이 공급되지 않은 광파표지는 태양광을 이용한 전력공급시스템을 사용하고 있다. 이러한 전력공급시스템에서는 충 방전조절기의 역할이 매우 중요하다. 항로표지의 효과적인 관리를 위해 도입된 IT기술(AIS통신 등)은 광파표지에 전력을 사용하는 장치를 추가하게 됨으로써 충 방전조절기의 중요성이 증가하고 있다. 현재 운용되는 충 방전조절기는 항로표지 내부에 부착되어 해상환경에 따라 점검 및 확인하는데 어려움이 있다. 이를 해결하기 위해서 본 논문에서는 충 방전조절기에 블루투스 모듈을 구성하여 근거리 점검이 가능한 모니터링 시스템을 제안하였다. 제안한 시스템은 도입 비용이 적고, 구성이 간편하여 다양한 항로표지에 응용가능한 장점이 있다. 또한 근거리에서 충 방전조절기의 실시간 상태정보를 확인할 수 있어서 점검 비용을 절감하고, 점검 시 발생 가능한 위험요소를 줄일 수 있다.

비파괴검사 분야에서 방사선원의 위치 확인을 위한 반도체 검출기 설계에 관한 연구 (The Study on Design of Semiconductor Detector for Checking the Position of a Radioactive Source in an NDT)

  • 김교태;김주희;한무재;허예지;안기정;박성광
    • 한국방사선학회논문지
    • /
    • 제11권3호
    • /
    • pp.171-175
    • /
    • 2017
  • 비파괴검사 분야에서는 작업자들의 안전을 확보하기 위해 방사선원에 대한 시스템 개발에 많은 시간과 재원을 투자하고 있으나 아직까지 사고 발생 확률은 높은 실정이다. 방사선에 대한 잠재적 사고를 미연에 방지하기 위해서는 방사선원의 위치를 직접적으로 검증하는 것이지만 아직까지 연구가 미흡한 실정이다. 이에 본 연구에서는 감마선조사기의 선원 가이드 튜브에서 방사선원의 위치를 감지할 수 있는 모니터링 시스템 개발을 위한 선행연구로써 몬테카를로 시뮬레이션을 통해 방사선 검출기에 대한 특성을 모의 추정하였다. 연구 결과, Ir-192의 감마선 에너지에 대한 방사선 검출기는 반도체 소재에 무관하게 $150{\mu}m$에서 2차 전자평형이 이루어지는 것으로 분석되었으며, 감마선 응답 특성은 $HgI_2$가 가장 우수할 것으로 기대된다. 이러한 결과는 차후 모니터링 시스템의 검출부에 위치하는 방사선 검출기의 최적화 두께를 결정하는데 기초자료로써 활용될 수 있을 것으로 기대되며, 이를 바탕으로 모니터링 시스템을 개발 시 방사선작업종사자가 위험을 쉽게 인지하여 안전을 확보할 수 있을 뿐만 아니라 잠재적인 방사선 사고에 대한 예방 및 선제적 대응이 가능함으로써 사회 안전망 구축 에 기여할 수 있을 것이다.

경기도 내 유통 견과종실류의 잔류농약 실태 모니터링 (Monitoring Pesticide Residues in Nuts and Seeds in Gyeonggi-do)

  • 이유나;문수경;이정희;김애란 ;문경은;강충원;이진희;박명기
    • 한국식품위생안전성학회지
    • /
    • 제38권3호
    • /
    • pp.152-157
    • /
    • 2023
  • 본 연구에서는 경기도 내 유통 중인 견과 종실류의 잔류농약 실태를 조사하고자 온라인 또는 유통매장을 통해 131건을 수거하여 조사하였다. 총 14품목의 견과종실류를 수거하였으며 339종의 잔류농약을 분석한 결과 131건 중 총 8건에서 검출되었으며 범위는 0.01 mg/kg-0.07 mg/kg 수준으로 나타났다. 검출된 시료 8건 중 7건이 잔류농약 기준을 초과하여 부적합으로 판정되었으며 부적합 7건 중 6건은 수입농산물에서 판정되었다. 중국산 호박씨의 경우 PLS가 적용된 피라클로스트로빈이 5건 검출되었으며 범위는 0.02 mg/kg-0.04 mg/kg 수준으로 나타났다. 인도산 참깨와 국내산 참깨에서도 펜디메탈린, 보스칼리드, 비펜트린이 각각 0.04 mg/kg, 0.05 mg/kg, 0.06 mg/kg으로 검출되어 부적합 수치를 보였다. 또한 검출된 8종의 농약에서 EDI/ADI (%) 값이 0.002%-0.372%으로 낮은 수준임을 확인하였다.

ICH-GCP와 선진 각국의 GCP 비교 (Comparison of Current GCPs on the Basis of the Contents in ICH-GCP)

  • 박혜연
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1997년도 추계학술대회
    • /
    • pp.57-74
    • /
    • 1997
  • To make a proposal for the revision of KGCP, ICH Harmonized Tripartite Guideline for Good Clinical Practice, which is on the stage of worldwide implementation, was compared with current GCPs of tripartite countries of ICH, namely USA, Europe and Japan as well as Korea. On the basis of the classification in ICH GCP, comprehensive comparisons among the corresponding articles of 4 regions or countries were made in the order of IRB / IEC, Investigator, Sponsor and Clinical Trial Protocol. Based on the comparisons of the contents in ICH-GCP with those in current GCPs, major suggestions for the revision of current KGCP can be made as follows. Firstly, the function of IRB / IEC needs to be strengthened for the initiation and continuation of clinical trial. Current 2-step approval system of IRB / IEC and Health Authorities requires to be converted into the system similar to that of developed countries. Secondly, sponsor's obligation needs to be tightened to control and assure the quality of clinical trial. Inspection of regulatory authorities should be made to perform during and / or after clinical trial, when it is necessary. In other words, sponsor should be made to establish written Standard Operating Procedures (SOPs) for all aspects of clinical trial including monitoring to ensure that trials are conducted and data are generated, documented, and reported in compliance with the protocol, GCP, and the applicable regulatory requirement (s). Besides, the provision of ‘Quality Control and Quality Assurance’ should be added to the protocol to establish the credibility of the result of the clinical trial.

  • PDF

이미지 처리 기법을 이용한 자기치유 콘크리트 수조의 균열 모니터링 현장적용 평가 (Evaluation of Crack Monitoring Field Application of Self-healing Concrete Water Tank Using Image Processing Techniques)

  • 오상혁;문대중
    • 한국건설순환자원학회논문집
    • /
    • 제10권4호
    • /
    • pp.593-599
    • /
    • 2022
  • 본 연구에서는 콘크리트 구조물의 주요 손상인 균열에 대한 효과적인 점검을 위하여 이미지 처리 기법을 이용한 균열 검출이 가능한 균열 모니터링 자동화 시스템 개발의 일환으로 머신비전을 이용하여 균열 촬영 장비를 제작하고 균열 이미지 촬영 및 분석이 가능한 프로그램을 개발하였다. 본 시스템은 기존의 육안으로 균열을 점검하는 외관조사를 대체하여 객관적이고 정량적인 데이터를 제공한다. 개발 시스템의 검증은 자기치유 콘크리트 수조 시공 현장에 적용하여 균열 검출 및 재령에 따른 균열폭의 변화량을 모니터링하였다. 이미지 분석을 통해 검출된 균열폭의 경우 디지털 현미경을 이용한 실측값과 차이가 최대 0.036 mm로 나타났으며, 자기치유 콘크리트의 재령 경과에 따른 균열 치유 효과를 균열폭 감소를 통해 확인할 수 있었다.