• Title/Summary/Keyword: Inspection Period

Search Result 432, Processing Time 0.025 seconds

Diagnosis of Work-related Musculoskeletal Disease through Moire Image Pattern and Treatment Measure using a Sling System (Moire' 영상무늬를 통한 근골격계질환의 진단과 현가장치를 이용한 치료방안)

  • Lee Sang-Yong;Lee Eun-Kyong;Kwon So-Hee;Jung He-Kyong;Kim Sam-Tae;Chong Myong-Soo;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 2003
  • The Musculoskeletal Disease has been ignored or turned away due to the difficulty of diagnosis and the vagueness of judgement up to now. Contrary to other diseases, there were many cases where the character of the Musculoskeletal Disease wasn't revealed through the objective inspection. And that's because the Musculoskeletal Disease appears for the most part due to muscular defect so it is impossible to diagnose the muscle by X-ray diagnosing the bone and it is also impossible to diagnose the fine damage of the muscle or tendon even by advanced device like MRI. As the nervous blood vessels or acupunctures pass through or are next to the muscle, the tension of the muscle put pressure on these so can become the direct or indirect causes of various kinds of pains or intern diseases. But in spite of that, for lack of proper equipment diagnosing the state of the muscle(Shortened.. Relaxed... or Hardened...) the muscle has been disregarded or neglected intentionally or unintentionally. While many people think themselves to be a muscular expert, if they don't see the shape of the muscle, that is just like blind treatment. But as now the equipment diagnosing the state of the muscle is developed, it seems that this problem can be settled. It was attempted in this study that the muscle or skeleton of the Musculoskeletal disease patients was diagno the treatment order and method were decided by a questionnaire survey and simple inspection, and the Musculoskeletal correction exercise using the muscle management and sling system made them escape from the Musculoskeletal disease, turning their muscle into more flexible and stronger muscle. As a result notwithstanding the limited treatment period '12 times', the improvement rate was as high as 74%, which showed that the muscle management and Musculoskeletal correction exercise had a great effect on the symptom improvement of the patients. If the treatment times had increased, the improvement rate also would have increased more.

  • PDF

A Statistical Fitness Test of Newell's 3-detector Simplification Method for Unexpected Incident Detection in the Expressway Traffic Flow (고속도로 돌발상황 검지를 위한 삼연속검지기 단순화 해법의 통계적 적합성 검정)

  • OH, Chang-Seok;RHO, Jeong Hyun;PARK, Young Wook
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.2
    • /
    • pp.146-157
    • /
    • 2016
  • The objective of this study is to actualize a statistical model of the 3-detector simplification model, which was proposed to detect outbreak situations by Daganzo in 1997 and to verify the statistical appropriacy thereof. This study presents the calculation process of the 3-detector simplification model and realizes the process using a statistics program. Firstly, the model was applied using data on detector of the main highways on which there is no entrances or exits. Moreover, in order to statistically verify the 3-detector simplification model, accumulative traffics for 30 seconds period, which reflects the dynamic changes of traffics due to shock wave, were estimated for outbreak traffics and steady flow, and the error of acquired data was statistically compared with that of the actual accumulative traffics. As a result, the error ratio between steady and incident cumulative flows has reached its maximum after 2-3 hours from an accident. Moreover, the incident traffic flows by accidents and the stade flows are heterogeneous in terms of their dispersion and means.

Structural Integrity Evaluation of Mechanically Fastened FRP Beams Under the Effects of Sustained Loads and Environments (지속하중과 환경영향을 받은 MF-FRP 보강보의 구조건전성 평가)

  • Lee, Jae-Ha;Kim, Woo-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Mechanically fastening FRP (MF-FRP) strips using nails and anchors, has been shown to provide a more ductile behavior to the strengthened structural element than using bonded FRP. To further advance the state of the knowledge on this strengthening method, the current study examined environmental effects for six months on MF-FRP beams. Reinforced concrete beams strengthened with mechanically fastened FRP strips and subjected to sustained loads for six months were exposed to outdoor weather and constant high temperatures ($40^{\circ}C$). For comparison, the behavior of RC beam with and without sustained loads was evaluated. Results from flexural tests did not show any significant degradation or change of failure mode as a result of sustained load and of environmental effects such as high temperatures and outdoor weather over a period of six months. Failure of the beams was governed by FRP delamination followed by concrete crushing as not much load applied to the nail and anchors because of slip effects.

A Study on the Elastic Restoration Characteristics According to Environmental Resistance Condition of Structural Sealing Finishing Materials (구조용 실링마감재의 내환경 조건에 따른 탄성복원 특성 연구)

  • Jang, Pil-Sung;Kang, Dong-Won;Hong, Soon-Gu;Kim, Young-Geun;Kim, Sung-Rae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.6-12
    • /
    • 2018
  • Recently, The use of the curtain wall method is increasing in construction. The curtain wall construction is widely applied to the exterior wall of the building for shortening construction period and economical efficiency. However, the replacement of deterioration of the weather resistance and structural behavior of the sealing material connecting the curtain wall method and the glass frame is necessary for introduction of the stable curtain wall method and quality improvement in accordance with KS F 4910 standard. In this study, the elastic restoring force test was performed in the external environment. In this study, the deterioration of the sealant was evaluated for structural sealants. In Korea, studies on the variable displacement behavior of structural sealants are lacked. In this study, the reproduced results in laboratory conditions are compared with the deteriorating conditions exposed to the external environment, and they are reflected in the design of sealing materials in the future. According to the results of the study, it was confirmed that the existing structure sealant meets the quality standard of KS F 4910, but in the conditions performed in this study, adhesion failure of the specimen and cracking of the surface occurred. Especially, in the weather resistance test, it is necessary to evaluate the long-term durability performance of the structural sealant used in the curtain wall method by checking the insoluble state of all the test pieces. Therefore, in order to apply a conventional structural sealant to the site, it is necessary to introduce another durability performance evaluation.

Experimental Study on the Behavior of Building Hardware with Joint Details (접합 방법에 따른 하지철물 구조물의 거동에 관한 실험적 연구)

  • Hong, Seonguk;Kim, Seunghun;Baek, Kiyoul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.190-198
    • /
    • 2018
  • In recent years, non-welded building hardware has been installed by bolt assembly is used. The non-welded building hardware method can reduce accidents caused by welding, and can be constructed by bolt assembly, which can reduce labor costs and shorten the construction period. However, there is a need for a method to compensate for the occurrence of buckling at the time of construction. The purpose of this study is to evaluate the behavior of joints between steel pipe and fastener and to evaluate the behavior of joints of non-welded and welded hardware frame. As a result, it was found that the foundation steel structure without welded joints was deformed to a rotation angle of member much larger than the allowable interlayer displacement angle 0.01 to 0.02 required according to the seismic load rating in the seismic load resistance system.

Variation of Seismic Behavior of Continuous Skew Plate Girder Bridges According to the Arrangement of Bearings (받침배치에 따른 연속 플레이트 거더 사교의 지진거동 변화)

  • Moon, Seong Kwon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.124-135
    • /
    • 2011
  • The capacity of bearings installed at abutments and piers for continuous bridges is usually determined by the magnitude of the maximum vertical reaction at each support and the capacity of bearings placed at piers is higher than that at abutments. In this study, the possibility of the improved seismic performance of base-isolated continuous skew bridges was investigated by analysing the variation of the seismic behavior of them according to three arrangements of bearings. Based on the conventional arrangement of bearings(Case A), three arrangements of bearings such as Case A, Case B and Case C were selected considering the variation of the horizontal stiffness of the lead rubber bearing(LRB) installed at the pier. The seismic behavior of the total 36 skew bridges was investigated by conducting the response spectrum analysis using the hybrid response spectrum considered the effect of LRB's damping. Results of analyses show that a more desirable seismic behavior of base-isolated continuous skew bridges can be obtained by reducing the magnitude of the horizontal stiffness of LRB placed at the pier to similar to or less than that of LRB installed at abutments. The variation of LRB's stiffness at the pier brings about period elongation and the change of mode shapes of base-isolated skew bridges and results in the reduction of the total base shear, the maximum base shear at the pier and the girder stresses. Although positive effects on the seismic behavior of base-isolated skew bridges caused by the change of arrangement of bearings decreased slighty with an increase in the flexibility of the substructure, the proposed arrangements of bearings bring about the improved seismic performance of base-isolated continuous skew plate girder bridges with less than 10m height of piers.

Performance Based Evaluation of Concrete Strength and Freeze-Thaw Resistance from Wind Speed - Sunlight Exposure Time Effect (풍속과 일조시간에 따른 콘크리트의 강도 및 동결융해 저항성 성능중심평가)

  • Kim, Tae-Kyun;Choi, Seung-Jai;Choi, Ji-Hun;Kim, Jang-Ho Jay
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.49-58
    • /
    • 2017
  • The phenomena that we experience in everyday life such as snow, rain, wind, and temperature are referred to as weather, and the average state of atmospheric phenomena that occur over a long period of time in a specific region is referred to as climate. In addition, significant variation of climate compared to the average state is referred to as climate change. Concrete structures can have various problems when exposed to elements. Among the problems, the freeze-thaw problem due to extreme climatic factors such as heavy rain and snowfall has become a particularly significant issue recently. The concrete that has been subjected to repeated freeze-thaw rather than too high or low temperature shows serious degradation of durability, and the performance of structures with degraded performance is difficult to recover. Therefore, in this study, concrete durability performance with respect to freeze-thaw from curing conditions change due to wind speed and sunshine exposure time. Concrete freeze-thaw experiment are performed. using wind speed and sunlight exposure time. Also, performance based evaluation through the satisfaction curve based on the freeze-thaw test results are performed.

Crack and Time Effect on Chloride Diffusion Coefficient in Nuclear Power Plant Concrete with 1 Year Curing Period (1년 양생된 고강도 원전 콘크리트의 염화물 확산에 대한 균열 및 시간효과)

  • Chun, Ju-Hyun;Ryu, Hwa-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • Concrete structure for nuclear power plant is mass concrete structure with large wall depth and easily permits cracking in early age due to hydration heat and drying shrinkage. It always needs cooling water so that usually located near to sea shore. The crack on concrete surface permits rapid chloride intrusion and also causes more rapid corrosion in the steel. In the study, the effect of age and crack width on chloride diffusion is evaluated for the concrete for nuclear power plant with 6000 psi strength. For the work, various crack widths with 0.0~1.4 mm are induced and accelerated diffusion test is performed for concrete with 56 days, 180days, and 365 days. With increasing crack width over 1.0mm, diffusion coefficient is enlarged to 2.7~3.1 times and significant reduction of diffusion is evaluated due to age effect. Furthermore, apparent diffusion coefficient and surface chloride content are evaluated for the concrete with various crack width exposed to atmospheric zone with salt spraying at the age of 180 days. The results are also analyzed with those from accelerated diffusion test.

An Experimental Study on the Period of Cold Joint Occurrence Effecting Shear Bond Performances of UHSCC (콜드조인트 발생시간이 초고강도 섬유보강 시멘트 복합체의 전단 접착 성능에 미치는 영향에 관한 실험적 연구)

  • Kim, Min-Seong;Yang, Hyun-Min;Lee, Han-Seung;Cho, Keun-hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 2016
  • The purpose of this study is to evaluate the performance on the compressive bonding shear strength of ultra-high strength steel fiber reinforced cementitous composites(UHSCC). As a result of compressive bonding shear strength through Direct shear test, It was found that the specimen($150{\times}150{\times}150mm$) of NC(Normal concrete) + NC showed similar compressive bonding shear strength at whole experimental level. On the other hand, the specimen of UHSCC + UHSCC showed decrease of compressive bonding shear strength from after 30 minutes of the retarded placement than 0 minute. As a result of analyzing failure mode of bonding interface, It was found that the specimen of NC + NC showed mixed failure at whole experimental level. In case of the specimen of UHSCC + UHSCC, it showed interface failure from the specimen that are 30 minutes, 60 minutes and 90 minutes of delay of concrete placing. As a result of analyzing XRD test in terms of the placement interface on the specimen of NC and UHSCC, relatively much amount of $SiO_2$ was detected from the specimen of UHSCC than that of NC. It is judged that the most of main components of coating film shown in the specimen of UHSCC is $SiO_2$. In conclusion, it is judged that UHSCC which is made from after 30 minutes of delay of concrete placing is unable to be used as structural member because of deterioration of bonding performance. From later study, it is judged that the improvement of bonding performance from the part of cold joint occurrence is necessary through the interface preparation method.

Analysis of Undergraduate's Leadership through the Servant Leadership Curriculum (Focusing on the factors of professors, academic performance, friendship, and department) (섬김의 리더십 교육과정을 통한 대학생 리더십 분석 (교수, 학업성적, 교우관계, 학과 요인 중심으로))

  • Han, Man-Oh
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.2
    • /
    • pp.109-115
    • /
    • 2020
  • This study is for analyzing and verifying of impact and effect for undergraduate's leadership through the Servant Leadership curriculum. The Servant Leadership's lecture and period for this study has been done for 15th week, and 2 hours for each week. To verify the effectiveness of the Servant Leadership, we've composed 2 different groups and compared the results of the preliminary inspection and post-test, then analyzed the differences of the preliminary inspection and post-test with focusing on the research hypothesis. Statistical treatment of this study made use of the statistical program SPSS/WIN 22.0, and the method of analysis was done with factor analysis for validity verification of each factor. We used Frequency analysis like frequency and percentage about the generalities of the subject. Looking at the investigation of this research, the overalls such as the University Facilities, curriculum, professor and a school report was higher after training than before training the general programs, On the other hand, friendship and major got lower after training than before, but appeared no significant difference in the statistics. The whole leadership has appeared as heighten after education than before, through the servant Leadership's lecture Empowerment and personality were appeared as heighten after education than before, and Similarly on Human relations.