Comparison of Heat Transfer Performance and Pressure Drop of Fin-Tube and Aluminum Heat Exchangers (핀-튜브 열교환기와 알루미늄 열교환기의 전열성능과 압력강하 특성비교)

  • Chang, Keun-Sun;Lee, Hyun-Su;Kim, Jae-Duck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.222-229
    • /
    • 2009
  • This study presents comparison of heat transfer and air side friction characteristics in a condenser condition of air conditioner between Louver fin-tube heat exchangers and aluminum parallel heat exchangers. All experiments are performed using an air-enthalpy type calorimeter, which is designed based on the method described in ASHRAE standards. The air velocities crossing the heat exchanger tubes are varied from 0.7 to 1.6 m/s with 0.3 m/s interval, maintaining air dry temperature and relative humidity at $20^{\circ}C$ and 60% respectively. Water temperature and flow rate inside the tube are $70^{\circ}C$ and 10 LPM, respectively. Experimental results show that the heat transfer performances of aluminum heat exchangers are 17-163% higher than those of Louver fin-tube heat exchangers based on the data per unit volume, mass, and heat transfer area, whereas air side pressure drops of aluminum heat exchangers are 19-81% lower.

A Case Study on Active Usage of the Storage Space Outside Housing Unit of Residential Complex (공동주택 세대외부창고의 활성화 방안을 위한 사례 연구)

  • Song, Jihyun;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.1
    • /
    • pp.58-67
    • /
    • 2018
  • This study aims to analyze the cases of storage space outside housing unit and propose the activation plan. The issue of storage in residential complex has continued to be reported. This is more salient due to the recent preference trend for small houses, the constant increase of living goods and the limitation of the available space inside housing unit. Although more apartment houses are trying to have individual storage in the exterior space to address these issues, there is still a paucity of the related studies and more studies are required. In this study, we conducted on-site investigation and user interview of each case to propose active usage of the storage space outside housing unit. Result of this study shows that the most crucial factor to improve is 'accessibility' in order to activate the storage space. Storage room should be located close to each household or the individual parking space. The second factor is the size and the structure of the storage room. The sufficient space for keeping and taking large objects out are required. The front of the storage room should have a clogged structure to insure privacy. The third is the provision of suitable support programs such as the system that occupants can check remotely what items are in their storage rooms, garage sale, laundry service, auto cleaning system and rental program. Those programs are required for efficient management and activation of space. Another requirement is to improve environmental factors which include maintenance of optimal temperature and humidity, automatic ventilation system, control of individual lights, and security enhancement. Based on the results of the survey, we provide basic data which can be used for practical space planning to activate exterior storage space of the housing unit. Further surveys are required to develop this study by obtaining more data for generalization.

Evaluation of the Wear Comfort of Women's Fitted Sports T-shirts Made from Cool-Touch Fabrics (냉감 소재를 활용한 밀착형 여성 스포츠 상의의 착용쾌적성 평가)

  • Kim, Soyoung;Choi, Jiyoung;Lee, Heeran;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.5
    • /
    • pp.929-938
    • /
    • 2017
  • This research investigated the effects of cool touch fabrics on thermo-regulating physical properties and subjective evaluation using a 3D fitted women's T-shirts in wear test. Qmax, clothing microclimate, microclimate wettedness, thermogram and subjective vote were observed during rest-right after an exercise-rest protocol. As a result, there was no single determining physical variable to explain the reasons of cool sensations of T-shirts made of cool touch fabric across the entire protocol. Qmax could partly predict a wear sensation at the initial stage when only insensible perspiration was presented. Simultaneous observation of temperature/humidity gradient understand from the inside to the outside of the clothing layer or microclimate wettedness calculated using vapor pressure were helpful to figure out the performance of cool touch fabric, especially at the later stage of the protocol when sweating was excessive. It was especially difficult to connect thermo-regulating physical variables to the subjective evaluation during transient conditions such as 'right after exercise' stage. It is necessary to measure the amount of heat and moisture transferred from the skin to the outside of clothing along with the physical properties measured in this study to understand the detailed mechanisms of why a cool sensation is evoked from tight fitting T-shirts made of newly developed cool touch fabrics.

Environmental Analysis in the Windowless Laying Hen Houses (무창산란계사의 환경분석에 관한 연구)

  • ;Hongwei Xin;Yi Liang
    • Journal of Biosystems Engineering
    • /
    • v.28 no.3
    • /
    • pp.225-230
    • /
    • 2003
  • This study was carried out to analyze the environmental variation of layer house at Iowa State in the USA. The analyzed seasons for this study were summer and winter. Analyzing factors are inside temperature and relative humidity, carbon dioxide concentration, ammonia concentration and emission. All factors were collected every 30 second from each house with portable monitoring units. In this study, two types of laying hen houses were monitored at the same season. One was a manure belt house, the other was a high-rise house. In order to estimate the ventilation rates of the laying hen houses, carbon dioxide concentration balance was used in this study. Ammonia concentrations and emission rates of the manure belt house are much lower than those of the high rise house. Daily mean ammonia concentrations in the manure belt house and high-rise house ranged from 3 to 7 ppm and 5 to 34 ppm, respectively. The daily ammonia emission rates averaged 0.68g/h$\cdot$500kg and 0.73g/h$\cdot$500kg for the manure belt house and 0.93g/h$\cdot$500kg and 2.89g/h$\cdot$500kg for the high-rise house in summertime and wintertime, respectively. Summertime is associated with much higher ammonia emission rates than wintertime because of much higher ventilation rates and ambient air temperature, even though the concentrations may be lower.

Implementation of Swinery Integrated Management System in Ubiquitous Agricultural Environments (유비쿼터스 농업환경에서의 돈사 통합관리 시스템 구현)

  • Hwang, Jeong-Hwan;Lee, Meong-Hun;Ju, Hui-Dong;Lee, Ho-Chul;Kang, Hyun-Joong;Yoe, Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.252-262
    • /
    • 2010
  • Recently, the USN (Ubiquitous Sensor Network) technology is emerging as an aspect of digital convergence trends which is being rapidly evolving in the whole society. The technological feasibility for the various application services using the USN is researched in numerous industries, but, in the agricultural field, the market of USN application service, technology adoption and commercialization have been delayed. In the agricultural field, the ubiquitous technologies could lead to huge change in the conventional surroundings such as growth environment of livestock, crop cultivation and harvest. In this paper, to offer a integrated management, we construct a u-swinery(ubiquitous swinery) system which is consisted with USN environmental sensors to collect information from physical phenomenon such as luminance, relative humidity, temperature and ammonia gas. Numbers of CCTV were also installed to monitor inside and outside of the swinery. The u-swinery integrated management system can monitor and control the condition of swinery from remote sites. Furthermore, by gathering the cumulative environmental data from the system, the optimal growth condition for the livestock could be created.

A Study on The Development of Container Security Device(CSD) based on Active RFID (능동형 RFID 기반 컨테이너 보안 장치(CSD)의 개발에 관한 연구)

  • Choi, Hyung-Rim;Kim, Jae-Joong;Kang, Moo-Hong;Shin, Joong-Jo;Shon, Jung-Rock;Moon, Young-Sik;Lee, Eun-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.244-251
    • /
    • 2010
  • CSD is Active RFID based Container Security Device which is proposed by the U.S Department of Home Security. It is mounted inside the container to sense opening of the container door. ConTracer is the CSD which is developed in this research whose major features are sensing door opening status as well as history inquiring on internal environment and shock to the container by mounting the temperature/humidity/shock sensors. Moreover, its RFID frequency bandwidth uses 433MHz and 2.4GHz to correspond actively to the radio regulations used by different countries. This paper introduces the development trend of CSD, compares the ConTracer which is developed thru this research and other company's CSD, and introduces CSD System which is designed and established using ConTracer. Finally, the implemented CSD System is verified by applying the demonstration service to container distribution between Korea and China.

중요민속자료 제112호 장흥임씨 수의류의 보존처리

  • An, Hui-Gyun;Han, Seong-Hui;Jeong, Hui-Jin;Kim, Gi-Seop
    • 보존과학연구
    • /
    • s.6
    • /
    • pp.96-110
    • /
    • 1985
  • This report is briefly thied to introduce the kinds of clothes for the body of deceased and special features of remains in the era of the middle of Yidynasty found in Changheung IM's tomb, and some remarks related to the conservation treatment for shrouds as well. The contents of this report are summed up as follows:1. Included with the clothes of dead body of IM's clan were 2 pcs. Of woman's jacket, 2 pcs. of underpants, 1pcs. of single layered overcoat twithout cotton, 1pcs.of women's overcoat with a single layered thin cotton inside, women's socks, cushoned mattress, straw shoes and other hemp fabrics etc. By the observation of these remains, it is considered that they dressed the deceased with new cloth taken from the unsuals not prepared specially and stored beforehand for such as occasion as does it nowadays.2. As to the conservation treatment, the materials were comparatively good and so they employed general tank washing method with special neutrality liquid soap(made by Lab, of Household Products, Pacific R & D Center) for cleaning imbrued matrials on the clothes. After cleaning and drying naturally at a shade place, remains put into apaulowania tree box were fumigated by mixed gas (M. B. + E. O.) for prevention of damages from fungi and insects.3. Desirable environment control for scientific conservation of such kinds of cellulose textiles is to be illuminated at below 50Lux, temperature 16-18℃, relative humidity 45-60%($\pm$4%) and removed the dust. For the prevention of the damaging fungi and insects, it is desirable to fumigate by mixed gas (M.B.+E.O.) once a year.

  • PDF

Literatual study on Atopic dermatitis (아토피 피부염에 관한 문헌적(文獻的) 고찰(考察))

  • Cha, Kwan-Bae;Kim, Yoon-Sik;Seol, In-Chan
    • Journal of Haehwa Medicine
    • /
    • v.14 no.2
    • /
    • pp.113-126
    • /
    • 2005
  • Atopic dermatitis(AD) is a chronic disease that affects the skin. "Atopic" refers to a group of diseases where there is often an inherited tendency to develop other allergic conditions, such as asthma and hay fever. In AD, symptoms vary from person to person. The most common symptoms are dry, itchy skin and rashes on the face, inside the elbows and behind the knees, and on the hands and feet. Although AD may occur at any age, it most often begins in infancy and childhood. The cause of AD is not known, but the disease seems to result from a combination of hereditary and environmental factors along with malfunction of the body's immune system. In contrast to that, the results from literatual study in oriental medicine are as follows; 1. The causes of AD are considered to be Mosusigisadok(母受時氣毒), Waegampoongsubyeol(外感風濕熱), Guasiksinlayeolmul(過食辛辣熱物), Ohbokonje(誤服溫劑). 2. The symptoms are fever, flushed face, red eyes, oliguria, constipation and itching. 3. Chungyeolhaedok(淸熱解毒) would be the basic method of treatment, and it divides into two categories; Subhyung(濕型) and Gunhyung(乾型). In Subhyung(濕型), AD is treated by Josub(燥濕), Chungyeol(淸熱) and Jiyang(止痒) whereas Chungyeol(淸熱), Jiyang(止痒), Jesub(除濕) in Gunhyung(乾型). 4. To prevent further damage and enhance quality of life, it is necessary to keep the temperature and humidity favorable, and healing the skin and keeping it healthy are important. Developing and sticking with a daily skin care routine is critical to preventing flares. Changing the diet and psychological stability may also be helpful to relieve symptoms of AD.

  • PDF

Study on Performance of Lithium-Silicate Permeation and Changing Prosity Structure according to Water Content (수분의 함수율에 따른 공극구조의 변화와 리튬실리케이트의 침투성)

  • Kim, Kwang-Ki;Moon, Hyung-Jae;Kim, Jeong-Jin;Park, Soon-Jeon;Lee, Joo-Ho;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.769-772
    • /
    • 2008
  • Pores can become factors of reducing the capacity of concrete by being path of degradation factors and moisture can fill up pores inside of concrete, so evaluating the effect of unidirectional permeability due to moisture on pore structure of concrete structure is very important. Therefore, the change of pore structure in cases of 0%, 40%, 60%, 80% and 90% humidity being maintained on test specimens and in case of Lithium Silicate, which is chemical compound, being coated were evaluated. As a result, the condensation due to moisture could be confirmed since unidirectional permeability was decreased and the density of Pore Structure was improved as the percentage of water content was being increased. And, solution-type Lithium Silicate fills up pores of sizes around 1$\mu$m in the condition of carrying water and improves the density but the range of capacity improvement due to osmosis will be limited according to functional conditions.

  • PDF

Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof (쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과)

  • Song, Bong-Geun;Kim, Gyeong-Ah;Park, Kyung-Hun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.