• Title/Summary/Keyword: Inside diameter

Search Result 736, Processing Time 0.033 seconds

A Study on the Effect of Magnetic Field in Electrostatic Precipitator for Improving Precipitation Efficiency of Particulate Matter (미세먼지의 집진효율 향상을 위한 전기집진기의 자계인가특성에 대한 연구)

  • Park, Jae-Youn;Han, Sang-Bo;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.122-129
    • /
    • 2008
  • This paper gives the experimental results for the effective precipitation of particulated matter(PM) below 1[${\mu}m$] of diameter using the electrostatic precipitator, which is designed by ourselves. In order to improve the precipitation efficiency, the vertical and parallel magnetic field to the electric field is applied simultaneously by arranging ferrite magnets. When the parallel magnetic field is applied, the precipitation efficiency does not improve in comparison with non-magnets. However, when the vertical magnetic field is applied, it is improved about 5[%] more than the case of non-magnetized ferrite plate used. In addition, when the magnets are installed at the center of ground plate electrodes, the precipitation efficiency is ranged from 17 to 32[%] under the applied voltage of 5[kV]. It is similar to the case of the magnet arrangement at the front part of ground electrode. Also, the precipitation efficiency is more improved by arranging magnets as the inside part and zigzag on the electrodes. Especially, large particles of 0.7 and 1[${\mu}m$] is more easily captured by electrostatic precipitator. Consequently, it is convinced that the vertical magnetic field is more desirable than parallel magnetic field on the electric field for the effective treatment of particulated matter.

Blood Vessel Strain Imaging Using Linear Array Transducer (선형 트랜스듀서를 이용한 혈관 변형률 영상법)

  • Ahn, Dong-Ki;Jeong, Mok-Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.880-890
    • /
    • 2010
  • The intrasvascular ultrasound (IVUS) imaging technique is used to diagnose cerebrovascular diseases such as stroke. Recently, elasticity imaging methods have been investigated to diagnose blood clots attached to blood vessel intima. However, the IVUS imaging technique is an invasive method that requires a transducer to be inserted into blood vessel. In this paper, strain images are obtained of blood clots attached to blood vessel intima with data acquired from outside the blood vessel using a linear array transducer. In order to measure the displacement of blood vessel accurately, experimental data are acquired by steering ultrasound beams so that they can intersect the blood vessel wall at right angles. The acquired rf data are demodulated to the baseband. The resulting complex baseband signals are then processed by an autocorrelation algorithm to compute the blood vessel movement and thereby produce strain image. This proposed method is verified by experiments on a plastic blood vessel mimicking phantom. The efficacy of the proposed method was verified using a home-made blood vessel mimicking phantom. The blood vessel mimicking phantom was constructed by making a 6 mm diameter hollow cylinder inside it to simulate a blood vessel and adhering 2 mm thick soft plaque to the inner wall of the hollow cylinder. The RF data were acquired using a clinical ultrasound scanner (Accuvix XQ, Medison, Seoul. Korea) with a 7.5 MHz linear array transducer by steering ultrasound beams in steps of $1^{\circ}$ from $-40^{\circ}$ to $40^{\circ}$ for a total of 81 angles. Experimental results show that the plaque region near the blood vessel wall is softer than background tissue. Although the imaging region is restricted due to the limited range of angles for which scan lines are perpendicular to the wall, the feasibility of strain imaging is demonstrated.

Microsurgical Training using Preserved Saphenous Vein (혈관문합 연습을 위한 보존된 복재정맥의 활용)

  • Song, Jennifer K.;Hwang, So-Min;Lim, Kwang-Ryeol;Jung, Yong-Hui
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.391-395
    • /
    • 2010
  • Purpose: Given that the critical nature of the microvascular anastomosis to what is often a long and difficult reconstructive operation, trainees need to have a high level of microsurgical competence before being allowed to perform microsurgery on patients. Some artificial substitutes and dead or live animal models have been used to improve manual dexterity under the operating microscope. Yet, most surgeons are not equipped with such models, so search for easy available and appropriate microsurgical practice model have been an issue. Umbilical artery, placental vessels and gastroepiploic arteries have been previously suggested as a microsurgical training model, which involves other surgical departments. The purpose of this article is to introduce that saphenous vein specimen obtained from varicose vein surgery is useful and has many advantages as training model for the practice of microvascular anastomosis. Methods: The conventional technique using perforation/inversion method with a metallic stripper is widely performed for varicose vein patients. The stripper is inserted through disconnected safeno-femoral junction and retrieved at the knee or the medial side of ankle. The length of saphenous vein specimens removed is about that of one's leg and inversed from inside out. Obtained saphenous vein specimens are re-inversed and cleansed with normal saline, to be readily available for microsurgical practice. Preserved in a squeezed wet saline gauze and refrigerated, frozen or glycerated specimens were investigated into their comparative quality for microsurgical practice. Results: Varicose vein surgery remains one of the common operations performed in the field of plastic surgery. Convenient informed consent regarding the vessel donation can be easily signed. The diameter of the obtained saphenous vein is as variable as 1.5 to 6 mm, which is already stripped, and is in sufficient length corresponding to that of patient's leg. Vessels specimens were available for microsurgical practice within 1 week period when preserved with squeezed wet saline gauze, and the preservation period could be extended monthly by freezing it. Conclusion: Saphenous vein obtained from varicose vein patients provide with variable size of vessel lumen with sufficient length. The practice can be cost effective and does not require microsurgical laboratory. Additionally there is no need of involving other surgical departments in acquiring vessel specimens. Furthermore, simple preservation method of refrigerating for a week or freezing with squeezed wet saline gauze for a month period, allow the saphenous vein obtained after varicose vein surgery as an excellent model for the microsurgical practice.

A Master Packaging System for Preserving Qualities of Peaches in the Fresh Produce Supply Chain (농산물 유통과정에서 복숭아의 품질유지를 위한 마스터 포장 시스템)

  • Jeong, Mijin;An, Duck Soon;Park, Woo Po;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.1
    • /
    • pp.7-10
    • /
    • 2013
  • A packaging system integrated in primary and secondary packages to deliver consumers fresh peach in the produce supply chain was designed and its effectiveness on quality preservation was tested. The master packaging system was designed to contain 6 individual polypropylene film (PP, $30{\mu}m$ thickness) packages of 300 g peach fruit inside $35{\mu}m$ thick low density polyethylene (LDPE) bag located in a corrugated paperboard box. As a variable to attain the desired package atmosphere around the fruit during cold storage and subsequent retail display at higher temperature, different numbers (1, 3 and 7) of microperforations in $59{\mu}m$ diameter were tested on the individual PP packages. As control treatment, six fruits were placed without wrapping in a corrugated paperboard box. During the storage at $5^{\circ}C$, the control and individual packages were periodically separated from the box or master package, moved to the simulated retail shelf conditions of $20^{\circ}C$ and then stored for 3 more days with package atmosphere and fruit quality being measured. The package with 7 microperforations was the best in the ability to attain beneficial MA of 6~10% $O_2$ and 11~19% $CO_2$ around the fruit during the chilled storage at $5^{\circ}C$ and simulated retail display at $20^{\circ}C$. Packages with smaller number of microperforations resulted in anaerobic atmosphere at the low temperature storage and/or the subsequent high temperature display. Compared to control, all the treatments with master packaging system gave better retention of fruit firmness with significantly less weight loss.

  • PDF

The heat transfer characteristics of viscoelastic non-newtonian fluids in the entrance region of circular tube flows (원형관속을 유동하는 점탄성 유체의 입구 영역 열전달 특성에 관한 연구)

  • 엄정섭;황태성;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.1032-1043
    • /
    • 1989
  • The heat transfer characteristics of the drag reducing polymer solutions are investigated experimentally in the thermal entrance region of circular tube flows. Fluids used in experiments are the aqueous solutions of high molecular polymer, polyacrylamide Separan AP-273 and the range of polymer concentrations is from 20 to 1000 wppm. Two stainless steel tubes with inside diameter 8.5mm(L/D=712) and 10.3mm(L/D=1160) are used for the heat transfer flow loops. The flow loop is set up to measure friction factors and heat transfer coefficients of test sections in two different modes; the recirculating flow system and once-through flow system. The test tubes are heated directly by electricity to apply the constant heat flux boundary conditions to the wall. Three different types of adaptors are used to observe the effects of the upstream flow conditions of the heat transfer test sections. The viscosity and characteristic relaxation time of the test fluids circulating in the flow system are measured by the capillary tube viscometer and falling ball viscometer at regular time intervals. The installed adaptors exhibit slight effect on the entrance heat transfer of Newtonian fluid. However, no noticeable effects are observed for the entrance heat transfer of the drag reducing fluids. The order of magnitude of the thermal entrance lengths of the drag reducing fluids which follow the minimum friction asymptote is much longer than that of Newtonian fluids in turbulent flows. A new dimensionless parameter, the viscoelastic Graetz number, is defined and all the experimental data are recasted in terms of the viscoelastic Graetz number. The local Nusselt number of the viscoelastic fluids is represented as a function of flow behavior index n and the viscoelastic Graetz number. As degradation continues the viscosity and the characteristic relaxation time of the testing fluids decrease. Weissenberg number defined by the relaxation time and D/V appears to be a proper dimensionless parameter in describing degradation effects on heat transfer of the viscoelastic fluids.

Development of a Semi-Atomatic Protocol for embodiment of a desirable 3D breast shape and deployment of bra cup pattern (3차원의 바람직한 유방형상 구현을 위한 Semi-Atomatic Protocol 개발 및 브래지어 컵 패턴으로의 전개)

  • Sohn, Boo-hyun;Kweon, Soo-ae
    • Journal of Fashion Business
    • /
    • v.20 no.4
    • /
    • pp.189-206
    • /
    • 2016
  • A breast model was for the human body was devised by studying a body scan and human body index of a desirable breast type. Thus, when manufacturing various 3D models, these results can accordingly become a fundamental basis for realizing a desirable breast model. This study aims to provide a basic data for designing the cup patterns of brassieres in order to improve the function and wearing comfort. The comfort of three kinds of brassieres were compared: one manufactured by the actual measured size; another manufactured as per the ratio of desirable upper and lower breast lengths; and the third manufactured by the 3D model attained by the desirable human body ratio. In this study, we suggest a process for realizing the desirable breast model using the ratio of bust breadth and waist front length, which are the components for deciding the appropriate position and size of breast, and which are easy to measure. The ideal breast shape is an equilateral triangle formed by connecting the nipple with the center of the clavicle. After deciding the interval between the nipples, this value can be used to configure the locations of nipples by drawing a tangent, with equal length, from the anterior neck point (which is the center of clavicle) to the nipple. Also, since inside points of breast do not exist, the outer point of breast, upper point of breast, and below point of breast on the same plane, and the depths from the nipple point to the respective points, are applied to simulate a 3D image, by modifications along the x, y, and z axes. Depending on the type of breast, the length from the center of shoulder to the nipple, the diameter of breast, upper length of breast, and the position of nipple, are different. In conical or protruding breast, the wearing sensation is better when the nipple point of brassiere was lifted, by modifying the upper and lower lengths of breast. Considering the wearing sensation and function of a brassiere, it was better to leave the wearer's size as it is and use a pad within the same cup, rather than increase the basal area of the breast in order to increase the volume.

Study on the Modeling Technique for Prediction about Pressure Drop of an Intravenous Lung Assist Device (혈관 내 폐 보조장치의 압력손실 예측을 위한 모델링기법에 관한 연구)

  • 김기범;권대규;정경락
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.293-299
    • /
    • 2003
  • In this paper, the correlation of Pressure drop about the Newtonian and non-Newtonian fluid was investigated experimentally for vibrating intravascular lung assist device (VIVLAD) and we determined correlation equation to make a prediction about Pressure drop for designing VIVLAD. Design conditions to predict the pressure drop of the modules were studied through an experimental modeling before inserting the artificial lung assist device into as venous. Experiments were performed by distilled water, glycerol/water mixed solution(40% glycerol) of Newtonian fluids. and the bovine blood of non-Newtonian fluids. These fluids were flowed outside and parallel of hollow fiber membranes. Also we measured pressure drop according to the number of the fiber membranes which ware inserted into the inside diameter of shell of 3 cm, and developed the prediction equations by curve fitting method based on correlation between the experimental pressure drop and the frontal area or the packing density of device. The result showed that the Pressure drop and the friction factor of the water/glycerol mixed solution were similar to that of bovine blood. It was showed that the water/glycerol mixed solution (40% glycerol) could be used for measuring the pressure drop and the friction factor instead of the bovine blood. Also, we could estimate the prediction equation of pressure drop and friction factor as the function of Packing density at the number of hollow fibers. We obtained the reliance of the prediction equations because the pressure drop and the friction factor measured from the experiments were similar to that from the prediction equation. These results may be used to further usefulness for the design of VIVLAD.

Software Package for Pipe Hydraulics Calculation for Single and Two Phase Flow (배관 유동의 주요 변수계산을 위한 소프트웨어 시스템의 개발)

  • Chang, Jaehun;Lee, Gunhee;Jung, Minyoung;Baek, Heumkyung;Lee, Changha;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.628-636
    • /
    • 2019
  • In various industrial processes, piping serves as a link between unit processes and is an essential installation for internal flow. Therefore, the optimum design of the piping system is very important in terms of safety and cost, which requires the estimation of the pressure drop, flow rate, pipe size, etc. in the piping system. In this study, we developed a software that determines pressure drop, flow rate, and pipe size when any two of these design variables are known. We categorized the flows into single phase, homogeneous two phase, and separated two phase flows, and applied suitable calculation models accordingly. We also constructed a system library for the calculation of the pipe material, relative roughness, fluid property, and friction coefficients to minimize user input. We further created a costing library according to the piping material for the calculation of the investment cost of the pipe per unit length. We implemented all these functions in an integrated environment using a graphical user interface for user convenience, and C # programming language. Finally, we verified the accuracy of the software using literature data and examples from an industrial process with obtained deviations of 1% and 8.8% for the single phase and two-phase models.

The Numerical Study on Effect of the Droplet Sizes on Internal Mass Transfer in the Spray Type Scrubber (분무형 스크러버에 내에서 액적크기에 따른 물질전달에 관한 전산해석적 연구)

  • Lee, Chanhyun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.19-32
    • /
    • 2019
  • As regional air pollution gets worse by the sulfur oxides emitted from various types of vessels passing through the many countries, the International Maritime Organization establishes the emission control areas and regulates sulfur dioxide in those areas. In order to satisfy these regional regulations, the fuel selection method and the exhaust gas post-treatment device are applied to the ships. Due to the economic reasons, the post-treatment method of exhaust gas for reducing the amount of sulfur oxides discharged is mainly preferred. The scrubber which is dominantly used in the ships are the spray type system where the sprayed liquid drops used for capturing the soluble sulfur dioxides in the exhaust gas. The performance of the spray type system depends on the size distribution of the sprayed droplets. In order to evaluate this performance, we designed counterflow type scrubber and cyclone scrubber and evaluated the desulfurization efficiency and the amount of droplet evaporation according to the size of each droplet by using computational fluid dynamics. The Eulerian-Eulerian analysis method was used because the scrubber had a gas-liquid two-phase flow inside the scrubber. When the diameter of the droplet was $100{\mu}m$, $300{\mu}m$, $500{\mu}m$ and $700{\mu}m$. As a result, both of scrubbers showed high desulfurization efficiency and low evaporation amount at $500{\mu}m$ and $700{\mu}m$.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.