• 제목/요약/키워드: Inside diameter

검색결과 736건 처리시간 0.032초

토끼 경골에서 치과용 임프란트의 RBM 및 SLA 표면처리에 따른 조직계측학적 연구 (HISTOMORPHOMETRIC STUDY OF DENTAL IMPLANTS WITH RBM AND SLA SURFACE IN THE RABBIT TIBIA)

  • 송국현;김일규;장금수;김규남;최진웅
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권6호
    • /
    • pp.514-523
    • /
    • 2006
  • The purpose of the present study was to evaluate the effects of several implant surface treatments to the bone formation, by placing Machined implants, 75${\mu}m$ Calcium phosphate-blasted implants and $Al_2O_3$-blasted and acid-etched implants in rabbit tibia through histomorphometric study. Two animals of each group were sacrificed at 2, 4, 8 weeks. The specimens containing the implants were dehydrated and embedded into hard methylmethacrylate plastic. Thereafter, the sections were ground to 50${\mu}m$. The specimens were stained with Villanueva bone stain for a light microscopic study. The results were as follows; 1. When the surface roughness of three different implants was measured by Surfcorder, the Ra of the Machined group, the RBM group and the SLA group was 0.16${\mu}m$, 0.44${\mu}m$, and 1.08${\mu}m$. 2. When examining the surfaces of the implants in the scanning microscope, Machined implant has the smooth surface with a few scratches, RBM implant has the rough surface with curled ridges and valleys, and SLA implant has the rough surface structures such as sharp protruding parts and micropits measuring 1-2${\mu}m$ in diameter. 3. After 2 weeks of implantation, the percentage of bone-to-implant contact of the Machined group, the RBM group and the SLA group was 26.86%, 35.40% and 45.99%. However, its differences between each group decreased during the healing periods. 4. After 2 weeks of implantation, the percentage of bone area inside the threads of the Machined group, the RBM group and the SLA group were 21.55%, 30.43% and 41.18%. However, its difference of bone area between machined group and surface treatment groups was maintained but the difference within the surface treatment groups decreased during the healing periods. In summary, the amount of bone formation in RBM and SLA group was greater than Machined group in early healing stage. These results suggest that RBM and SLA implants can reduce the healing period for osseointegration and may be suitable for early function.

재배조건에 따른 맥간의 형태적 및 물리적 특성변화에 관한 연구 II. 재식밀도와 시비량이 맥간의 형태적 및 물리적 특성에 미치는 영향 (Studies on Morphological and Physical Characteristics of Wheat and Barley Culms under Different Cultural Conditions II. Effects of Planting Density and Amount of Fertilizer Applied on Morphological and Physical Characteristics of Barley Culms)

  • 조장환;이홍석
    • 한국작물학회지
    • /
    • 제14권
    • /
    • pp.111-115
    • /
    • 1973
  • 대맥재배에 있어서 재식밀도와 시비량의 차이가 간의 형태적, 생리적 특성의 변화와 수량에 미치는 영향을 구명코저 시험한 결과를 요약하면 다음과 같다. (1) 시비량에 있어서는 표준시구보다 배비구에서 간 내, 외경, 간 벽후가 두꺼우며 단위간 건물중이 높고, 간장이 다소 커지며 수중, 수수가 많았다. (2) 재식밀도에 있어서는 소식일수록 도복에 견딜수 있는 방향으로 변화되었으나, 수량면을 고려하면 $5{\times}$5cm, $10{\times}$10cm 구가 알맞은 편이고 $15{\times}$15cm구와 $20{\times}$20cm구는 거의 비슷하였다. (3) 좌절하중, 좌절시 Bending moment, 단면2차 moment, 단면계수등은 표준비구보다 배비구가 높아 도복에 강하며, 재식밀도면에서는 소식일수록 전기형질의 수치가 높았다. (4) 도복지수는 밀식일 경우는 표준비구가 높으며 $10{\times}$10cm구 이상 소식일 때는 시비량과 재식거리에 따른 도복지수의 차이는 없었다. (5) 수량면에서는 배비가 좋으며, 안전다수를 위한 재식거리는 $5{\times}$5cm구가 가장 좋았다.

  • PDF

재배조건에 따른 맥간의 형태적 및 생리적 특성변화에 관한 연구 I. 질소추비시기가 맥간의 형태적 및 생리적특성에 미치는 영향 (Studies on Morphological and Physical Characteristics of Wheat and Barley Culms under Different Cultural Conditions 1. Effects of Top-Dressing Time of Nitrogen on Morphological and Physical Characteristics of Barley Culms)

  • 이홍석;조장환
    • 한국작물학회지
    • /
    • 제14권
    • /
    • pp.117-121
    • /
    • 1973
  • 대맥의 생육시기별로 질소비료를 추비하여 맥체의 형태적, 물리적 특성에 미치는 영향을 검토코져 시험을 실시한 결과를 요약하면 다음과 같다. 1. 질소 추비에 따른 대맥의 형태적 특성변화의 추이를 보면, 도복과 관련이 깊은 형질, 중, 3월 추비구가 제 3-5절간장이 짧아지고, 지상부 생체중, 단위간 건물중이 많으며, 간 외경, 내경이 굵고 간 벽후가 두꺼워 내도복성인 소질을 보였다. 2. 생리적 특성변화의 추이를 보면, 저항성을 표시하는 좌절하중, 좌절시 Bending moment가 3월 추비구가 가장 높아 도복저항성이 강하였다. 3. 간의 만곡난이를 나타내는 단면계수, 단면 2차 moment등이 3월 추비구가 극히 높아 만곡이 되지 낳고 도복의 종합적인 표시방법인 도복지수가 낮아 도복의 저항성 및 강도가 가장 강하였다. 4. 3월 추비구는 수중이 높고 주당수량이 높아 적전추비기로 구명되었다.

  • PDF

청색과 적색의 혼합LED광 처리가 인삼의 생육 및 진세노사이드 함량에 미치는 영향 (The Effect of Blue and Red LEDs Irradiation on The Growth Characteristics and Ginsenoside Content of Panax ginseng C. A. Meyer)

  • 성봉재;김현호;조진웅
    • 한국작물학회지
    • /
    • 제60권1호
    • /
    • pp.70-74
    • /
    • 2015
  • LED 청색광과 적색광을 2년근 인삼에 대하여 혼합 처리하여 생육 반응과 진세노사이드 함량에 미치는 영향을 알아 본 결과 인삼의 지상부의 엽면적과 건물중은 청색광과 적색광의 비율이 1:1 처리에서 상대적으로 가장 높았으나 인삼 뿌리의 건물중은 1:3 비율이 가장 컸다. 진세노사이드 함량은 지상부은 청색광과 적색광 비율이 1:1에서 가장 높았지만 인삼 뿌리의 함량은 1:1 비율이 가장 낮았다.

유동층반응기에서 화학증기침투에 의한 C/SiC의 복합체 제조시 변수의 영향 연구 (Studies on the Effects of Variables on the Fabrication Of C/SiC Composite by Chemical Vapor Infiltration in a Fluidized Bed Reactor)

  • 이성주;김영준;김미현;임병오;정귀영
    • 공업화학
    • /
    • 제10권6호
    • /
    • pp.843-847
    • /
    • 1999
  • 본 연구에서는 유동층-화학증기침투에 의해 이염화이메틸규소(DDS)와 수소로부터 생성된 탄화규소를 활성탄에 증착시킨 세라믹 탄소/탄화규소복합체가 제조되었다. 4~12, 12~20, 20~40 mesh의 활성탄이 사용되었다. 증착 후 반응물인 이염화이메틸규소의 농도, 활성탄의 크기, 반응압력, 반응시간에 따른 반응후 각 시료의 표면적과 증착량 및 증착양상을 관찰하였다. 실험결과 DDS의 농도가 낮고 반응압력이 작을수록 시료 기공내에 고른 증착을 갖는 것을 알 수 있었다. 또한 기공직경과 표면적들이 어떠한 시점에서 최소값을 갖는 것으로 기공내부 증착에서 입자외부 표면 증착으로 바뀜을 알 수 있었다. DDS의 농도가 낮고 반응압력이 낮을 때 작은 탄화규소입자가 활성탄 표면에 더욱 고르게 증착되었다. 이 결과들은 SEM, TGA, 기공도측정장치, BET에 의해 확인되었다.

  • PDF

의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구 (Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test)

  • 김형균;윤재호;최성대
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.389-394
    • /
    • 2015
  • 의료영상 검사는 정보기술 및 의료장비의 발달로 인체의 해부학적 구조를 묘사하는 능력이 날로 발전하고 있다. 그러나 상지회전이 필요한 어깨관절 의료영상 검사에서는 인체구조의 복잡성으로 정확한 자세유지가 의료영상의 진단적 가치에 매우 중요하다. 자기공명검사의 경우 긴 검사시간과 고정된 자세가 필요해 검사자의 노력과 환자의 의지만으로 재현성 있는 검사가 불가능하다. 이에 상지회전과 정량적 각도가 가능한 보조기구를 개발하여 진단적 가치가있는 의료영상 검사를 하고자하였다. 본 연구는 선행 연구의 결과를 바탕으로 보조기구를 제작하였으며, 공학용 프로그램인 CATIA 프로그램으로 3차원 모델링을 설계하여, 3D프린터로 최종 완성된 보조기구를 제작하였다. 사용된 3D 프린터는 Stratasys Objet350 Connex 모델이며, 재질은 광경화성 수지를 사용하였다. 완성된 보조기구의 크기는 $120{\times}150{\times}190mm$이며, 손잡이부의 내경은 125.9 mm 로 디자인되었다. 보조기구는 총 4개의 부품으로 바디부(외부), 손잡이부(내부), 고정단자, 연결부로 구성되었으며 바디부와 손잡이부는 원활한 회전이 가능하도록 2.1 mm의 유격이 유지되도록 하였다. 손잡이부에는 360o 눈금선을 표시하여 환자마다 관찰에 필요한 회전각도를 기록할 수 있도록 하여 추적검사나 양쪽검사에 적용할 수 있도록 하였다.

북태평양 중부 해산어장에 있어서 저층 선주낙의 어획실태 (Fishing investigation of vertical bottom longline fisheries in sea mount of central northern Pacific)

  • 오택윤;김영승;조삼광;김인옥;최석관;고정락;양원석
    • 수산해양기술연구
    • /
    • 제41권3호
    • /
    • pp.188-198
    • /
    • 2005
  • This study was conducted to survey the catches of vertical bottom longline fisheries in the sea mount of central northern Pacific($30^{\circ}-42^{\circ}N$, $170^{\circ}-175^{\circ}E$), during the period of July 1 to August 25,2004 by commercial fishing vessel. The number of 57 test fishing was carried out in the central northern Pacific during 43 days and the total catches were 21,092.4kg as 19 fish species, CPUE/day and catches/day were 185 baskets and 490.5kg, respectively. Main fish species caught from the experimental fishing were Squalus mitsukurii (66.3%), Coelorhyrchus asperocephaius (11.7%) and Helicolenus avius (9.8%) and, average inside diameter for fish mouth was 4.0cm over. Catch ratio according to each fishing ground was the order of F, D, J, B and C. Catch ratio fur water depth was the order of 450-500m, 350-400m, 300-350m, 400-450m, 1000-1100m and 500-550m and, main species by water depth was Squalus mitsukurii for 300-400m, Etmopterus lucifer for 300-550m, Coelorhyrchus asperocephaius far 1,000m over. Catch ratio according to the kind of hooks was higher at the hook no.6 for Squalus mitsukurii and no. 5 for Etmopterus lucifer and, catch ratio by baits was higher at squid for Squalus mitsukurii, saury and eel for Helicolemus avius and saury for Etmopterus lucifer. Accordingly, it is thought that the extension of fishing hours is needed with the reduction of damage and loss for fishing gears during fishing operation.

방적성 Plasma 처리 필름으로 피복된 플라스틱온실의 풋고추 생육 (Growth of Green Pepper(Capsicum annuum L.) in a Plastic Greenhouse Covered with Anti-dropping Plasma Film)

  • 전희;김경제;김진영;김현환;이시영
    • 생물환경조절학회지
    • /
    • 제9권3호
    • /
    • pp.156-160
    • /
    • 2000
  • 플라즈마 필름은 플라스틱 필름 표면의 유적성을 향상시키기 위하여 고전압처리 되었다. 플라즈마 필름과 계면활성제 필름(대조구)를 각각 직경 25mm 두께 1.5mm 골조 파이프 하우스에 피복하였다. 또한 40일 플러그 육묘된 풋고추를 110cmx25cm 간격으로 정식하였다. 피복시 수온을 7$0^{\circ}C$로 처리된 수적발생 장치에서 나온 수증기가 필름 표면에서 응결되어 흘러내려 비이커에 모인 양을 150분 후에 측정한 결과, 플라즈마 필름에서 2.56mL.100$cm^{-2}$ , 계면활성제 필름에서 0.94mL.100$cm^{-2}$ 이 나왔다. 피복 60일 후 오전 8시 20분에 시설내 필름 표면에 부착된 수적량은 플라즈마 필름에서 0.34mL.100$cm^{-2}$ , 계면활성제필름에서 0.32mL.10$cm^{-2}$ 이었다. 광 투과율은 플라즈마 필름 피복시설이 계면활성제 피복시설 보다 2.0% 높았다. 그리고 시설내 기온은 플라즈마 필름 피복시설이 계면활성제 피복시설 보다 0.5$^{\circ}C$ 높았다. 그러나 상대습도는 차이가 없었다. 풋고추 초장, 엽면적, 건물중 및 초기수량 또한 처리간에 차이가 없었다.

  • PDF

아미노실란 기능화된 MCM-41과 SBA-15 세공 내 메탈로센 담지 및 에틸렌 중합 (Immobilization of Metallocene inside the Aminosilane-Functionalized Nanopore of SBA-15 and MCM-41 and Its Ethylene Polymerization)

  • 셀레도니오 줄리마르;이정숙;고영수
    • 공업화학
    • /
    • 제25권4호
    • /
    • pp.396-400
    • /
    • 2014
  • 메조포러스 물질, SBA-15와 MCM-41의 세공 표면을 유기실란인 3-aminopropyltrimethoxysilane (1NS)와 N-[(3-trimethoxysilyl) propyl]ethylenediamine (2NS)를 이용하여 그라프팅법으로 표면 기능화하였다. 표면 기능화된 메조포러스 물질에 $(n-BuCp)_2ZrCl_2$와 조촉매 methylaluminoxane (MAO)를 담지하여 에틸렌 중합을 실시하였다. SBA-15/2NS/$(n-BuCp)_2ZrCl_2$ 촉매는 그라프팅되는 2NS의 양이 증가할수록 담지된 Zr와 Al 함량은 감소하였으며, MCM-41/2NS/(n-BuCp)2ZrCl2 촉매는 2NS의 양이 증가할수록 Zr 함량은 증가하지만 Al 함량은 감소하였다. SBA-15/2NS/$(n-BuCp)_2ZrCl_2$ 촉매의 중합 활성은 2NS의 투입량을 증가할수록 감소하였다. 이는 많은 양의 2NS가 표면에 그라프팅되는 경우 기공부피와 기공크기가 작아지게 되고 따라서 MAO와 메탈로센 촉매 담지량이 감소하게 되기 때문이다. 그러나 SBA-15보다 작은 기공을 갖는 MCM-41을 2NS로 표면 기능화되면 큰 분자 크기를 갖는 조촉매 MAO는 담지 되기 어려워 낮은 MAO 담지량을 갖게 된다. 따라서 메탈로센 담지량은 약간 증가하게 되고 이에 따라 중합 활성이 증가하였다.

표면처리가 다른 5종 임플랜트의 안정성에 관한 연구 (A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS)

  • 김선종;신상완;정성민;류재준
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.