• 제목/요약/키워드: Inside diameter

검색결과 736건 처리시간 0.028초

Superhydrophobic nanostructured non-woven fabric using plasma modification

  • Shin, Bong-Su;Lee, Kwang-Reoul;Kim, Ho-Young;Moon, Myoung-Woon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.320-320
    • /
    • 2011
  • We describe fabrication of superhydrophobic surface on non-woven fabric (NWF) having nano-hairy structures and a hydrophobic surface coating. Oxygen plasma was irradiated on NWF for nano-texuring and a precursor of HMDSO (Hexamethydisiloxane) was introduced as a surface chemical modification for obtaining superhydrophobicity using 13.56 MHz radio frequency-Plasma Enhanced Chemical Vapor Deposition (rf-PECVD). O2 plasma treatment time was varied from 1 min to 60 min at a bias voltage of 400V, which fabricated pillar-like structures with diameter of 30 nm and height of 150 nm on NWF. Subsequently, hydrophobic coating using hexamethyldisiloxane vapor was deposited with 10 nm thickness on NWF substrate at a bias voltage of 400 V. We evaluate superhydrophobicity of the modified NWF with sessile drop using goniometer and high speed camera, in which aspect ratio of nanohairy structures, contact angle and contact angle hysteresis of the surfaces were measured. With the increase of aspect ratio, the wetting angle increased from $103^{\circ}$ to $163^{\circ}$, and the contact angle hysteresis decreased dramatically below $5^{\circ}$. In addition, we had conducted experiment for nucleation and condensation of water via E-SEM. During increasing vapor pressure inside E-SEM from 3.7 Torr to over 6 Torr which is beyond saturation point at $2^{\circ}C$, we observed condensation of water droplet on the superhydropobic NWF. While the condensation of water on oxygen plasma treated NWF (superhydrophilic) occurred easily and rapidly, superhydrophobic NWF which was fabricated by oxygen and HMDSO was hardly wet even under supersaturation condition. From the result of wetting experiment and water condensation via E-SEM, it is confirmed that superhydrophobic NWF shows the grate water repellent abilities.

  • PDF

In Vitro Formation of Protein Nanoparticle Using Recombinant Human Ferritin H and L Chains Produced from E. coli

  • RO HYEON SU;PARK HYUN KYU;KIM MIN GON;CHUNG BONG HYUN
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권2호
    • /
    • pp.254-258
    • /
    • 2005
  • We have conducted in vitro reconstitution study of ferritin from its subunits FerH and FerL. For the reconstitution, FerH was produced from an expression vector construct in Escherichia coli and was purified from a heat treated cell extract by using one-step column chromatography. FerL was expressed as inclusion bodies. The denatured form of FerL was obtained by a simple washing step of the inclusion bodies with 3 M urea. The reconstitution experiment was conducted with various molar ratios of urea-denatured FerH and FerL to make the ferritin nanoparticle with a controlled composition of FerH and FerL. SDS-PAGE analysis of the reconstituted ferritins revealed that the reconstitution required the presence of more than 40 molar$\%$ of FerH in the reconstitution mixture. The assembly of the subunits into the ferritin nanoparticle was confmned by the presence of spherical particles with diameter of 10 nm by the atomic force microscopic image. Further analysis of the particles by using a transmission electron microscope revealed that the reconstituted particles exhibited different percentages of population with dense iron core. The reconstituted ferritin nanoparticles made with molar ratios of [FerH]/[FerL]=l00/0 and 60/40 showed that 80 to $90\%$ of the particles were apoferritin, devoid of iron core. On the contrary, all the particles formed with [FerH]/[FerL]=85/ 15 were found to contain the iron core. This suggests that although FerH can uptake iron, a minor portion of FerL, not exceeding $40\%$ at most, is required to deposit iron inside the particle.

밀폐형 2상 열사이폰내의 비등현상에 관한 가시화 연구 (A Visual Study on Nucleate Boiling Phenomena in a Closed Two-Phase Thermosyphon)

  • 강환국;오광헌;김철주;박이동;황영규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.185-198
    • /
    • 1995
  • This is an experimental study conducted to visualize the nucleate boiling phenomena and flow regimes occurring inside the liquid pool in a closed two-phase thermosyphon. To meet this purpose, an annular-type thermosyphon was designed and manufactured using a glass tube and a stainless steel tube, being assembled axisymmetrically. The heat to be supplied to the working fluid is generated within a very thin layer of stainless steel tube wall by applying a high frequency electromagnetic field through the induction coil, axisymmetrically set around the evaporator zone. Some important results were as follows ; 1) Considering the structural complexity of the tested thermosyphon, it showed good performance for the range of heat flux 2< q" <25kW/$m^2$ and saturation vapor pressure, 0.1<Pv<1.1bar 2) different type of nucleating boiling regimes were observed as described below, -Pulse boiling regime : Flow pattern changed cyclically with time during 1 cycle of pulse boiling process. The onset of Nucleation was followed by expulsive growing of vapor bubble, resulting in the so called blow-up phenomenon, massive expulsion of large amount of liquid around the bubble. -Transient : Some spherical vapor bobbles were observed growing out from 2~3 nucleating sites, that was dispersed at the lower part of the heated tube wall in the liquid pool. But the rest upper region above the nucleating sites were filled with churns or bubbles of vapor. -Continuous nucleate boiling regime : The whole zone of evaporator was filled with lots of spherical vapor bubbles, and the bubbles showed tendency to decrease in diameter as the heat flux increased.ased.

  • PDF

진동수주형 파력발전장치 공기실의 파력에너지 흡수효율 (Wave Energy Absorption Efficiency of Pneumatic Chamber of OWC Wave Energy Converter)

  • 홍기용;신승호;홍도천
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제10권3호
    • /
    • pp.173-180
    • /
    • 2007
  • 파력에너지 변환을 위해 설계된 착저식 진동수주형 공기실 내의 파진폭 변화를 우리나라 연안의 특징적인 파랑 조건을 적용하여 조사하였다. 진동수주형 공기실의 형상인자가 파력에너지 변환에 미치는 영향을 파력에너지의 흡수 효율 관점에서 분석하였다. 실험적 및 수치적 접근법을 함께 사용하여 그 결과들을 상호 비교하였으며, 주어진 파랑 분포 하에서 파력에너지 흡수가 최대가 되는 형상인자들의 최적화를 목적으로 연구가 수행되었다. 실험은 공기실의 이차적원 형상을 가정하여 이차원 조파수조에서 실시되었으며, 수치적 해석은 공기실 내에서는 변동하는 공기압을 고려할 수 있도록 Rankine Green 함수를 적용하고 공기실 밖에서는 Kelvin Green 함수를 적용하는 합성 적분방정식에 기초하여 수행되었다. 공기실 상부의 덕트 직경, 공기실 폭, 공기실 전면벽 및 후면벽의 깊이는 흡수되는 파력에너지의 크기와 정점 주기를 민감하게 변화시키는 주요한 형상인자들임을 확인하였다.

  • PDF

그라우트 품질을 고려한 텐던의 부식저항성 평가 (Evaluation of Corrosion Resistance with Grout Type and Tendon)

  • 류화성;안기홍;고경택;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권4호
    • /
    • pp.76-82
    • /
    • 2018
  • PSC 구조에서 덕트 내부의 그라우트는 텐던 부식에 효과적인 부식방어 기재이다. 본 연구에서는 일반적으로 사용되고 있는 그라우트와 낮은 물-시멘트비와 실리카 퓸을 혼입한 그라우트를 대상으로 역학적, 내구적 시험을 수행하였다. 높이 1000mm의 덕트를 이용하여 텐던 시스템을 제작하였으며, 두 가지 그라우트에 대하여 강도, 흡수율, 플로우, 블리딩, 팽창률 등을 평가하였다. 또한 내부 12.7mm 텐던에 대하여 ICM(Impressed Current Method)를 이용하여 2일 및 4일 동안 부식을 촉진시켰으며 부식량을 조사하였다. 개선된 그라우트에서는 10MPa 이상의 높은 강도와 50% 이하의 낮은 흡수율을 나타내었다. 또한 2일~4일 동안의 부식촉진실험에서 39.8%~48.2%의 뛰어난 부식감소율 나타내었다.

Influence of intake runner cross section design on the engine performance parameters of a four stroke, naturally aspirated carbureted SI engine

  • Singh, Somendra Pratap;Kumar, Vasu;Gupta, Dhruv;Kumar, Naveen
    • International Journal of Advanced Culture Technology
    • /
    • 제3권1호
    • /
    • pp.1-12
    • /
    • 2015
  • The current scenario of the transportation sector reflects the urgent need to address issues such as depletion of traditional fuel reserves and ever growing pollution levels. Researchers around the world are focussing on alternatives as well as optimisation of currently employed devices to reduce the pollution levels generated by the commonly used fuels. One such optimisation involves the study of air flow within the intake manifolds of SI engines. It is a well-known fact that alterations in the air manifolds of engines have a significant impact on the engine performance parameters, fuel consumption and emission levels. Previous works have demonstrated the impacts of runner lengths, diameter, plenum volume, taper angle of distribution manifolds and other factors on in-cylinder fluid motion and engine performance. However, a static setup provides an optimal configuration only at a specific engine speed. This paper aims to investigate the variations in the same parameters on a four stroke, naturally aspirated single cylinder SI engine through varying the cross section design over the intake runner with the aid of Computational Fluid Dynamics. The system consists of segments that form the intake runner with projections on the inside that allow various permutations of the intake runner segments. The various configurations provide the optimised fluid flow characteristics within the intake manifold at specific engine speed intervals. The variations such as turbulence, air fuel mixing are analysed using the three dimensional CFD software FLUENT. The results can be used further for developing an automated or manually adjustable intake manifold.

혈관 내 폐 보조장치 설계를 위한 압력손실 특성 평가 (Evaluations on the Characteristics of Pressure Drop f3r the Design of Intravascular Artificial Lung Assist Device)

  • 김기범;권대규;박재관;정경락;이삼철
    • 멤브레인
    • /
    • 제13권1호
    • /
    • pp.20-28
    • /
    • 2003
  • 본 연구에서는, 혈관 내 폐 보조장치를 설계할 때 혈액의 압력손실에 대한 영향을 받지 않는 최적의 설계조건을 찾기 위하여 압력손실을 예측할 수 있는 관계식을 유도하고자 하였다. 정맥 내경의 직경을 3 cm로 고정하고 삽입되는 중공사 개수의 변화에 따른 압력손실을 측정하였으며 실험에 의하여 얻어진 압력손실과 장치의 전면면적과의 상관관계를 curve fitting을 통하여 유도하였고, 유도되어진 관계식을 이용하여 정맥 내에 삽입되는 중공사 개수의 변화에 따른 압력손실을 예측하였다. 그리고 실험을 통하여 예측되어진 값과 비교 검토하여 유사성을 찾고자 하였다. 실험결과 장치에서 액체 유속의 변화에 따라 압력손실은 2차 함수 형태로 변화됨을 알 수 있었다. 또한 장치의 전면면적이 감소하면 압력손실은 증가하였고 충진율이 증가하면 압력손실도 증가함을 알 수 있었다. 장치 내에서의 압력손실에 대한 관계식을 장치의 전면면적과 충진율의 함수로 유도할 수 있었으며, 관계식에 의하여 압력손실을 예측할 수 있었다. 또한, 실험에 의한 압력손실과 비교하였을 때 유사한 경향성을 보여 줌으로써 압력손실 예측의 신뢰성을 얻을 수 있었다.

EXPERIMENTAL INVESTIGATIONS RELEVANT FOR HYDROGEN AND FISSION PRODUCT ISSUES RAISED BY THE FUKUSHIMA ACCIDENT

  • GUPTA, SANJEEV
    • Nuclear Engineering and Technology
    • /
    • 제47권1호
    • /
    • pp.11-25
    • /
    • 2015
  • The accident at Japan's Fukushima Daiichi nuclear power plant in March 2011, caused by an earthquake and a subsequent tsunami, resulted in a failure of the power systems that are needed to cool the reactors at the plant. The accident progression in the absence of heat removal systems caused Units 1-3 to undergo fuel melting. Containment pressurization and hydrogen explosions ultimately resulted in the escape of radioactivity from reactor containments into the atmosphere and ocean. Problems in containment venting operation, leakage from primary containment boundary to the reactor building, improper functioning of standby gas treatment system (SGTS), unmitigated hydrogen accumulation in the reactor building were identified as some of the reasons those added-up in the severity of the accident. The Fukushima accident not only initiated worldwide demand for installation of adequate control and mitigation measures to minimize the potential source term to the environment but also advocated assessment of the existing mitigation systems performance behavior under a wide range of postulated accident scenarios. The uncertainty in estimating the released fraction of the radionuclides due to the Fukushima accident also underlined the need for comprehensive understanding of fission product behavior as a function of the thermal hydraulic conditions and the type of gaseous, aqueous, and solid materials available for interaction, e.g., gas components, decontamination paint, aerosols, and water pools. In the light of the Fukushima accident, additional experimental needs identified for hydrogen and fission product issues need to be investigated in an integrated and optimized way. Additionally, as more and more passive safety systems, such as passive autocatalytic recombiners and filtered containment venting systems are being retrofitted in current reactors and also planned for future reactors, identified hydrogen and fission product issues will need to be coupled with the operation of passive safety systems in phenomena oriented and coupled effects experiments. In the present paper, potential hydrogen and fission product issues raised by the Fukushima accident are discussed. The discussion focuses on hydrogen and fission product behavior inside nuclear power plant containments under severe accident conditions. The relevant experimental investigations conducted in the technical scale containment THAI (thermal hydraulics, hydrogen, aerosols, and iodine) test facility (9.2 m high, 3.2 m in diameter, and $60m^3$ volume) are discussed in the light of the Fukushima accident.

화염의 상호작용에 의한 부분 예혼합화염의 화염날림 유속 확대 (Nozzle Configurations for Partially Premixed Interacting Jet Flame to Enhance Blowout Limits)

  • 김진현;이병준
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.71-79
    • /
    • 2005
  • For the non-premixed interacting jet flames, it has been reported that if eight small nozzles are arranged along the circle of $40{\sim}72$ times the diameter of single jet, the flames are not extinguished even in 200m/s. In this research, experiments were extended to the partially premixed cases to reduce both flame temperature and NOx emission. Nine nozzles were used- eight was evenly located along the perimeter of the imaginary circle and one at the geometric centre. The space between nozzles, S, the equivalence ratio, ${\phi}$, the exit velocity and the role of the jet from the centre nozzle were considered. Normally, flame was lifted and flame base was located inside the imaginary circle made by the nozzle. As nozzles went away from each other, blowout velocity increased and then decreased. The maximum blowout velocity diminished with the addition of air to the fuel stream. When the fuel and/or oxidizer were not fed through the centre nozzle, the maximum blowout velocity obtained by varying S and ${\phi}$ was around 160m/s. Optimum nozzle separation distance at which peak blowout velocity obtained also decreased with ${\phi}$ decrease. Flame base became leaner as approaching to the blowout. It seemed that lots of air was supplied to the flame stabilizing region by the entrainment and partially premixing. To approve this idea and to enhance the blowout velocity, fuel was supplied to the centre region. With the small amount of fuel through the centre nozzle, partially premixed flame could be sustained till sonic velocities. It seemed that the stabilizing mechanism in partially premixed interacting flame was different from that of non-premixed case because one was stabilized by the fuel supply through the centre nozzle but the other destabilized.

이상 유동층 반응기의 동특성에 관하여 (The Dynamic Characteristics of a Two Phase Fluidized Beds)

  • 서명교;서정호;강준수
    • 한국식품과학회지
    • /
    • 제25권3호
    • /
    • pp.210-213
    • /
    • 1993
  • 본 실험의 목적은 공극률과 상향유속의 관계에서 세입자의 유동특성을 고찰하는 데 있다 Column 내경은 유동층의 유속과 공극률과의 관계에 큰 영향을 미치지 못했으며 유속과 공극률과의 관계는 다음과 같다. $\frac{u}{u_t}={\varepsilon}^{3.703}$----모래$\frac{u}{u_t}={\varepsilon}^{3.5665}$----이온 교환수지$\frac{u}{u_t}={\varepsilon}^{4.066}$---GAC 또 유동층 매질입자는 구형을 사용하는 것이 일정유속에서 공극률을 낮게 유지할 수 있어 좋았고 실제로 미생물막 유동층 반응기에서는 미생물막이 매질에 부착되면 비중이 감소하므로 매질의 비중이 높을수록 유동층을 유지하기가 쉽다.

  • PDF