• 제목/요약/키워드: Inserted

검색결과 3,863건 처리시간 0.028초

박막형 고강도 폴리머 및 열화원인별 적용 몰탈내에 섬유로드를 삽입하는 RC 구조물의 보강공법 연구 (Flexural Reinforcement of RC Structures with composite fiber rods inserted in high strength special purposed polymer mortar for various deteriorated conditions.)

  • 정원용;이상근;박홍진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.828-835
    • /
    • 2000
  • In recent years, RC structures need reinforcement due to physical and chemical deterioration, reduction of serviceability and structural capacity. For reinforcement of RC structures, steel plate attachment, area increase and composite fiber sheet attachment methods are used, but there are some problems like weight increase, workability, quality control and fire resistance capacity. This study presents the effectiveness of flexural reinforcement of RC beams using composite rods that are inserted in high strength special purposed polymer mortar.

  • PDF

Wedge prism이 삽입된 단일종모우드 색소레이저 제작 (Construction of the Single Longitudinal Mode Dye Laser Inserted a Wedge Prism)

  • 고도경;김성호;이종민
    • 한국광학회지
    • /
    • 제5권1호
    • /
    • pp.80-83
    • /
    • 1994
  • Wedge prism이 삽입된 Littman형 색소 레이저 공진기를 제작하였다. 파장조정 거울 대신 wedge prism을 회전시킴으로써 미세한 파장조정이 가능함을 알 수 있었으며, 이때의 주파수 변화율은 약 20 GHz/deg이고 모우드 뜀없이 단일종모우드로 약 70 GHz를 연속적으로 변화시킬 수 있었다.

  • PDF

화약내 Gap을 통한 폭발력 제어 가능성에 대한 수치해석적 연구 (Controlling of detonation strength through inserted gaps in multi-material shock physics simulation)

  • 이진욱;여재익
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.275-278
    • /
    • 2012
  • We investigate the interaction between the propagation of detonation and inserted gaps in the high explosive. The Eulerian-based multi-material simulation code validated through comparison with experimental results was used. A series of gap materials is used to understand the detonation propagation characteristic in the presence of multiple gaps.

  • PDF

컴퓨터 내장형 냉각시스템 개발 (Development for Inserted Type Coling System in Computer)

  • 이현용;임선종
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.399-404
    • /
    • 2009
  • The research for computer cooling system has been researched briskly at home and abroad. Most of computer cooling systems are the air cooling method using cooling fan. The air cooling system are most widely used for low cost and easy installation but have limits in cooling. The water cooling system are good for cooling efficiency but bad for installation. This paper presents the developing for cooling system to be inserted in computer using thermoelectric module.

  • PDF

평판이 삽입된 IBBD 배열 안테나의 복사 특성 분석 (Analysis of Radiation Characteristics of Plate-Inserted IBBD Array Antennas)

  • 최환기;최학근;김도경;정영배;전순익
    • 한국전자파학회논문지
    • /
    • 제19권11호
    • /
    • pp.1213-1222
    • /
    • 2008
  • 본 논문에서는 지능형 안테나 시스템을 위하여 IBBD 배열 안테나의 소자 간격 및 소자 사이에 삽입된 평판의 높이에 따른 격리도를 분석하였다. 배열 소자 사이의 격리도는 두 소자 사이의 배열 간격이 증가할수록 향상되고, 두 소자 사이에 평판을 삽입한 경우가 평판이 없는 경우보다 약 13 dB의 격리도가 향상되는 것을 확인하였다. 또, 평판이 삽입된 $4{\times}4$ 소자 IBBD 배열 안테나를 제작하여 평판의 높이에 따른 복사 특성을 측정하고 분석하였다. 평판의 높이가 증가함에 따라 이득이 약간 감소하나, 복사 패턴 형상에는 거의 변화가 없었다.

Comparison of removal torques of SLActive® implant and blasted, laser-treated titanium implant in rabbit tibia bone healed with concentrated growth factor application

  • Park, Sang-Hun;Park, Kyung-Soon;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.110-115
    • /
    • 2016
  • PURPOSE. The purpose of this study was to compare the removal torques of a chemically modified SLActive implant and a blasted, laser-treated (BLT) implant, which were soaked in saline for 2 weeks after their surface modifications. The removal torques of the two implants were measured 4 weeks after their implantation into the bone defect area in rabbit tibias with concentrated growth factor (CGF) application. MATERIALS AND METHODS. To make artificial bone defects in the cortical layers of both tibias, an 8-mm diameter trephine bur was used. Then, prepared CGF was applied to the bony defect of the left tibia, and the bony defect of the right tibia was left unfilled. Four weeks later, the surgical sites of 16 rabbits were re-exposed. For 8 rabbits, the SLActive implants (Straumann, Switzerland) were inserted in the left tibia, and the BLT implants (CSM implant, Daegu, Korea) were inserted in the right tibia. For other rabbits, the BLT implants were inserted in the left tibia, and the SLActive implants were inserted in the right. Four weeks afger the insertion, torque removal was measured from 4 rabbits exterminated via $CO_2$ inhalation. RESULTS. No significant difference was observed between removal torques of the BLT implant and the SLActive implant (P>.05). CONCLUSION. It was found that BLT surface modification exhibited excellent osseointegration. In addition, CGF application did not affect the insertion and removal torque of the implants.

Characterization in Terms of the NUX Rule of G-inserted Mutant Hammerhead Ribozymes with High Level of Catalytic Power

  • Kuwabara, Tomoko;Warashina, Masaki;Kato, Yoshio;Kawasaki, Hiroaki;Taira, Kazunari
    • BMB Reports
    • /
    • 제34권1호
    • /
    • pp.51-58
    • /
    • 2001
  • Attempts using in vitro and in vivo selection procedures have been made to search for hammerhead ribozymes that have higher activities than the wild-type ribozyme and also to determine whether other sequences might be possible in the catalytic core of the hammerhead ribozyme. Active sequences selected in the past conformed broadly to the consensus core sequence except at A9, and no sequences were associated with higher activity than that of the hammerhead with the consensus core, an indication that the consensus sequence derived from viruses and virusoids is probably the optimal sequence [Vaish et al. (1997) Biochemistry 36, 6495-6501]. Recently, during construction of ribozyme expression vectors, we isolated a mutant hammerhead ribozyme, with an insertion of G between A9 and G10.1, that appeared to show significant activity [Kawasaki et al. (1996) Nucleic Acids Res. 24, 3010-3016; Kawasaki et al. (1998) Nature 393, 284-289]. We, therefore, characterized kinetic properties of the G-inserted mutant ribozymes in terms of the NUX rule. We demonstrate that the NUX rule is basically applicable to the G-inserted ribozymes and, more importantly, one type of G-inserted ribozyme was very active with $k_{cat}$, value of $6.4\;min^{-1}$ in 50 mM Tris-HCl (pH 8.0) and 10 mM $MgCl_2$ at $37^{\circ}C$.

  • PDF

경계선 검출에 대한 인접 칼라 영역간 테두리 선 삽입 효과의 분석 (Analyses of the Effect of Inserting Border Lines between Adjacent Color Regions on Detecting Boundaries)

  • 유현중;김우성;장영범
    • 전기전자학회논문지
    • /
    • 제10권1호
    • /
    • pp.87-95
    • /
    • 2006
  • 이 논문은 에지 검출을 위해 다른 컬러 영역사이의 테두리선을 삽입한 효과를 분석한다. 컬러코드를 인식하는 새로운 알고리즘을 제안하지는 않는다. RFID 방식을 보상하고, 디지털 카메라의 이용률이 높아져서 컬러코드에 대한 관심이 매우 증가하고 있다. 그러나 컬러의 왜곡이 심해지면 컬러코드의 확산을 저하시키게 된다. 왜곡된 컬러의 효과를 감소시키기위해서 영역내 화소 각각의 특성보다 각 영역 전체의 화소를 통계적으로 처리하는 방법이 바람직하다. 이 처리를 위해서 영상 영역화가 필요하다. 연결되지 않은 에지를 검출하기 위해 인접 컬러 영역사이에 2 화소 크기의 테두리선을 삽입한다. 테두리선은 흰색, 검은색 경계선이 사용된다. 2 종류의 테두리선이 삽입된 영상에 대한 에지 검출이 수행되고, 그 결과가 테두리선이 삽입되지 않은 에지 검출 결과와 비교한다. 검은 테두리선을 삽입한 결과는 지퍼효과에 의해 에지 검출 능력이 저하되고, 흰 테두리선을 삽입한 결과는 삽입하지 않은 경우보다 에지 검출 능력이 향상되었다.

  • PDF

Comparison of Complications of Peripherally Inserted Central Catheters with Ultrasound Guidance or Conventional Methods in Cancer Patients

  • Gong, Ping;Huang, Xin-En;Chen, Chuan-Ying;Liu, Jian-Hong;Meng, Ai-Feng;Feng, Ji-Feng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권5호
    • /
    • pp.1873-1875
    • /
    • 2012
  • Objective: To compare the complications of peripherally inserted central catheters (PICC) by a modified Seldinger technique under ultrasound guidance or the conventional (peel-away cannula) technique. Methods: From February to December of 2010, cancer patients who received PICC at the Department of Chemotherapy in Jiangsu Cancer Hospital were recruited into this study, and designated UPICC if their PICC lines were inserted under ultrasound guidance, otherwise CPICC if were performed by peel-away cannula technique. The rates of successful placement, hemorrhage around the insertion area, phlebitis, comfort of the insertion arm, infection and thrombus related to catheterization were analyzed and compared on days 1, 5 and 6 after PICC and thereafter. Results: A total of 180 cancer patients were recruited, 90 in each group. The rates of successful catheter placement between two groups differed with statistical significance (P <0.05), favoring UPICC. More phlebitis and finger swelling were detected in the CPICC group (P <0.05). From day 6 to the date the catheter was removed and thereafter, more venous thrombosis and a higher rate of discomfort of insertion arms were also observed in the CPICC group. Conclusion: Compared with CPICC, UPICC could improve the rate of successful insertion, reduce catheter related complications and increase comfort of the involved arm, thus deserving to be further investigated in randomized clinical studies.

중증 혈우병 항체 환자에서 시행한 말초삽입 중심혈관 카테터의 유용성 (Availability of peripheral inserted central catheters in severe hemophilia patients with inhibitors)

  • 박영실
    • Clinical and Experimental Pediatrics
    • /
    • 제51권12호
    • /
    • pp.1359-1362
    • /
    • 2008
  • 혈우병 환자에서 가장 효과적인 치료 방침은 응고 인자의 보충으로, 그를 위해 안전하고 오래 사용할 수 있는 정맥 확보가 필요하다. 그러나 중심 정맥으로의 port는 전신 마취와 일정한 입원이 필요하고, 혈우병 환자에서 시행할 경우 보험 삭감의 문제도 있다. 본 저자는 두 명의 중증 혈우병 항체 환자에게 말초 삽입 중심 정맥관을 삽입하였다. 환자들은 잦은 출혈 소견 때문에 응고 인자를 투여 받았으며, 그로 인하여 혈관 확보에 어려움이 있었다. 환자 나이는 7세와 11세였다. 제 8 응고 인자 활성도는 모두 1% 이하였으며, 제 8 응고 인자 항체 수치는 각각 160과 26.3 BU/mL였다. 말초 삽입 중심 정맥관은 초음파 인도 하에, 외래에서, 국소 마취로 쉽게 삽입되었다. 말초 삽입 중심 정맥관 삽입은 잦은 출혈을 보이는 혈우병 환자에게 사용해 볼 수 있는 방법이다.