• Title/Summary/Keyword: Input signal

Search Result 3,068, Processing Time 0.03 seconds

A Simple Technique on Estimating Delay Time Considering Crosstalk Noise in RC-class Interconnects Under Saturated Ramp Input (램프 입력에 대한 RC-class 연결선의 누화잡음을 고려한 지연시간 예측 기법)

  • Oh Kyoung-Mi;Kim Ki-Young;Kim Seok-Yoon
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.573-576
    • /
    • 2004
  • This paper proposes an analytic method that can estimate delay time considering crosstalk noise at an arbitrary node of RC-class interconnects under saturated ramp input using a simple closed-form expression. In the case of single interconnects, algebraic expression presented in existent research can estimate delay time under ramp input using delay time under step input, and we applied it to estimate delay time considering crosstalk noise. As the result, we can provide a intuitive analysis about signal integrity of circuits that include crosstalk noise reducing computational complexity significantly.

  • PDF

Power Factor Correction Method without Input Current Sensor (입력전류센서 없는 단상전력변환기의 역률개선 기법)

  • Jung, Young-Seok;Moon, Gun-Woo;Rho, Chung-Wook;Lee, Jun-Young;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.564-566
    • /
    • 1996
  • New simple control method of power factor correcting(PFC) boost convertor without instantaneous measurement of input current is proposed. Using the averaged model, the power factor correction scheme is presented. With the measurements of input voltage and output voltage, the control signal is generated to make the shape of the line current same as the input voltage. The validity of the controller is verified through the computer simulations.

  • PDF

A Study on Optimum control for Inrush current of Microwave Oven using Statistical Method (통계적 방법에 의한 전자레인지의 돌입전류 최적화 연구)

  • 이민기;고강훈;권순걸;이현우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.61-67
    • /
    • 2001
  • Magnetic flux saturation dependent on phase of initial input power to high voltage transformer used in Micro wave oven. To limit inrush current high voltage transformer the relay contact should be ˝ON˝ when the lowest point of input voltage phase. The improved circuit is form compensating interrupt signal Micom input so the relay contact can be ˝ON˝ when the inrush current is lower. Test results are presented that improved circuit satisfies the limit 50[A] of requirement for input voltage variation mode. And the result verified by statistical method.

  • PDF

Motion Analysis of Inchworm using Robust control and Input shaping (강인제어와 입력성형 기법을 이용한 이송 자벌레의 운동 해석)

  • Yang, Kwang-Yong;Hwang, Yun-Sik;Kim, Yeung-Shik;Kim, In-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.195-200
    • /
    • 2008
  • This paper presents motion control of the Inchworm composed of the piezoelectric actuators and mechanical elements. Piezoelectric actuator shows nonlinear response characteristics including hysteresis due to the ferroelectric characteristics. This paper proposes feedback control scheme to improve the ability of tracking response to complex input signal and suppress the phenomenon of hysteresis using the sliding mode control technique with the integrator. The sliding mode control system has the limit to minimize both the settle time and overshoot. For making up this limit, this paper also suggests input shaping technique suitable to the inchworm control system.

  • PDF

A Simple Technique on Estimating Delay Time Considering Crosstalk Noise in RC-class Interconnects Under Saturated Ramp Input (램프 입력에 대한 RC-class 연결선의 누화잡음을 고려한 지연시간 예측 기법)

  • Kim Ki-Young;Oh Kvung-Mi;Kim Seok-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.7
    • /
    • pp.299-303
    • /
    • 2005
  • This paper proposes an analytic method can estimate delay time considering crosstalk noise at an arbitrary node of RC-class interconnects under saturated ramp input using a simple closed-form expression. In the case of single interconnects, algebraic expression presented in existent research can estimate delay time under ramp input using delay time under step input, and we applied it to estimate delay time considering crosstalk noise. As the result, we can provide a intuitive analysis about signal integrity of circuits that include crosstalk noise reducing computational complexity significantly.

Adaptive Filter for Noise Cancellation of ECG's (심전도 신호의 잡음 제거를 위한 적응 필터)

  • Lee, Jae-Joon;Song, Chul-Gyu;Lee, Je-Suk;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.186-189
    • /
    • 1992
  • Adaptive fliter for noise cancellation of ECG is proposed. An adaptive noise canceller using the least mean squares algorithm is used to reduce unwanted noise. The adaptive noise canceller minimizes the mean-square error between a primary input, which is the noisy ECG, and a reference input, which is either noise that is correlated in some way with the noise in the primary input or a signal that is correlated only with ECG in the primary input.

  • PDF

A New Low Power High Level Synthesis for DSP (DSP를 위한 새로운 저전력 상위 레벨 합성)

  • 한태희;김영숙;인치호;김희석
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.101-104
    • /
    • 2002
  • This paper propose that is algorithm of power dissipation reduction in the high level synthesis design for DSP(Digital Signal Processor), as the portable terminal system recently demand high power dissipation. This paper obtain effect of power dissipation reduction and switching activity that increase correlation of operands as input data of function unit. The algorithm search loop or repeatedly data to the input operands of function unit. That can be reduce the power dissipation using the new low power high level synthesis algorithm. In this Paper, scheduling operation search same nodes from input DFG(Data Flow Graph) with correlation coefficient of first input node and among nodes. Function units consist a multiplier, an adder and a register. The power estimation method is added switching activity for each bits of nodes. The power estimation have good efficient using proposed algorithm. This paper result obtain more Power reduction of fifty percents after using a new low power algorithm in a function unit as multiplier.

  • PDF

Class A CMOS current conveyors (A급 CMOS 전류 콘베이어 (CCII))

  • 차형우
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.9
    • /
    • pp.1-9
    • /
    • 1997
  • Novel class A CMOS second-generation current conveyors (CCII) using 0.6.mu.m n-well standard CMOS process for high-frequency current-mode signal processing were developed. The CCII consists of a regulated current-cell for the voltage input and a cascode current mirror for the current output. In this architecture, the two input stages are coupled by current mirrors to reduce the current input impedance. Measurements of the fabricated cCII show that the current input impedance is 308 .ohm. and the 3-dB cutoff frequency when used as a voltage amplifier extends beyond 10MHz. The linear dynamic ranges of voltage and current are from -0.5V to 1.5V and from -100.mu.A to +120.mu.A for supply voltage V$\_$DD/ = -V$\_$SS/=2.5V, respectively. The power dissipation is 2 mW and the active chip area is 0.2 * 0.2 [mm$\^$2/].

  • PDF

Indentification of continuous systems in the presence of input-output measurement noises

  • Yang, Zi-Jiang;Sagara, Setsuo;Wada, Kiyoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1222-1227
    • /
    • 1990
  • The problem of identification of continuous systems is considered when both the discrete input and output measurements are contaminated by white noises. Using a predesigned digital low-pass filter, a discrete-time estimation model is constructed easily without direct approximations of system signal derivatives from sampled data. If the pass-band of the filter is designed so that it includes the main frequencies of both the system input and output signals in some range, the noise effects are sufficiently reduced, accurate estimates can be obtained by least squares(LS) algorithm in the presence of low measurement noises. Two classes of filters(infinite impulse response(IIR) filter and finite impulse response(FIR) filter) are employed. The former requires less computational burden and memory than the latter while the latter is suitable for the bias compensated least squares(BCLS) method, which compensates the bias of the LS estimate by the estimates of the input-output noise variances and thus yields unbiased estimates in the presence of high noises.

  • PDF

A Neuro-Fuzzy Inference System for Sensor Failure Detection Using Wavelet Denoising, PCA and SPRT

  • Na, Man-Gyun
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.483-497
    • /
    • 2001
  • In this work, a neuro-fuzzy inference system combined with the wavelet denoising, PCA (principal component analysis) and SPRT (sequential probability ratio test) methods is developed to detect the relevant sensor failure using other sensor signals. The wavelet denoising technique is applied to remove noise components in input signals into the neuro-fuzzy system The PCA is used to reduce the dimension of an input space without losing a significant amount of information. The PCA makes easy the selection of the input signals into the neuro-fuzzy system. Also, a lower dimensional input space usually reduces the time necessary to train a neuro-fuzzy system. The parameters of the neuro-fuzzy inference system which estimates the relevant sensor signal are optimized by a genetic algorithm and a least-squares algorithm. The residuals between the estimated signals and the measured signals are used to detect whether the sensors are failed or not. The SPRT is used in this failure detection algorithm. The proposed sensor-monitoring algorithm was verified through applications to the pressurizer water level and the hot-leg flowrate sensors in pressurized water reactors.

  • PDF