• 제목/요약/키워드: Input power level

검색결과 585건 처리시간 0.03초

MACCS II 코드를 이용한 국내 경수로 및 중수로형 원전의 소외결말분석 (Off-Site Consequence Analysis for PWR and PHWR Types of Nuclear Power Plants Using MACCS II Code)

  • 전호준;지문구;황석원
    • 한국안전학회지
    • /
    • 제26권5호
    • /
    • pp.105-109
    • /
    • 2011
  • Since a severe accident, which happens in low frequency, can cause serious damages, the interests in off-site consequence analysis for a nuclear power plant have been increased after Chernobyl, TMI and Fukushima accidents. Consequences, which are the effects on health and environment caused by released radioisotopes, are evaluated using MACCS II code based on the method of Level 3 PSA. To perform a consequence analysis for the reference plants, the input data of the code were generated such as meteorological data, population distribution, release fractions, and so on. Using these input data, acute and lifetime dose as an organ, CCDF for early fatalities and latent cancer fatalities, and average individual risk were analyzed by using MACCS II code in this study. These results might contribute to establishing accident management plan and quantitative health object.

New Three-Level PWM DC/DC Converter - Analysis, Design and Experiments

  • Lin, Bor-Ren;Chen, Chih-Chieh
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.30-39
    • /
    • 2014
  • This paper studies a new three-level pulse-width modulation (PWM) resonant converter for high input voltage and high load current applications. In order to use high frequency power MOSFETs for high input voltage applications, a three-level DC converter with two clamped diodes and a flying capacitor is adopted in the proposed circuit. For high load current applications, the secondary sides of the proposed converter are connected in parallel to reduce the size of the magnetic core and copper windings and to decrease the current rating of the rectifier diodes. In order to share the load current and reduce the switch counts, three resonant converters with the same active switches are adopted in the proposed circuit. Two transformers with a series connection in the primary side and a parallel connection in the secondary side are adopted in each converter to balance the secondary side currents. To overcome the drawback of a wide range of switching frequencies in conventional series resonant converters, the duty cycle control is adopted in the proposed circuit to achieve zero current switching (ZCS) turn-off for the rectifier diodes and zero voltage switching (ZVS) turn-on for the active switches. Finally, experimental results are provided to verify the effectiveness of the proposed converter.

증기 발생기 수위제어를 위한 모델예측제어기 설계 (Design of Model Predictive Controller for Water Level control in the Steam Generator of a nuclear Power Plants)

  • 손덕현;이창구
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권8호
    • /
    • pp.376-383
    • /
    • 2001
  • Factors leading to poor control of the steam generator in a nuclear power plant are nonminimum phase characteristics, unreliable of flow measurements and nonlinear characteristics, which increase more at low power(below 20%) operation. And the study of problems for water level control in the steam generator is that design water level controller only power renge, not entire. This paper introduces a model predictive control(MPC) algorithm for solving poor control factors and quadratic programming(QP) for solving input constraints. Also presents the design method of stable model predictive controller in the entire power range. The simulation results show the efficiency of proposed MPC controller by comparing with PI controller, and effect of the design parameters.

  • PDF

무정전전원장치용 3-레벨 인터리브드 충방전기에 대한 연구 (A Study on 3-level Interleaved Charger-Discharger for Uninterruptible Power Supplies)

  • 구태근;이인환;조영훈
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.535-542
    • /
    • 2017
  • This paper proposes a simple 3-level interleaved charger-discharger for the uninterruptible power supply (UPS) with various combinations of battery cells. The proposed converter not only improves charging and discharging efficiency, but also reduces the physical volume and the cost. Furthermore, the converter also offers the capability of the neutral point voltage, so that more stable operation can be obtained. In addition, the proposed converter significantly reduces the ripple current of the battery inductor, thereby providing an expected life extension of the battery. Experimental results for a 300kVA UPS prototype verify the validity of the proposed converter. The proposed charger-discharger is suitable for UPSs and energy storage systems (ESSs) with wide input battery voltage ranges.

Power Flow Control at the Subnetwork-Level in Microgrids

  • Liu, Kun;Khan, Muhammad Mansoor;Rana, Ahmad;Fei, Dong
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.588-603
    • /
    • 2018
  • This paper presents the idea of a smart load that can adjust the input power flow based on the intermittent power available from RESs (Renewable Energy Resources) to regulate the line voltage, and draw a constant power from the grid. To this effect, an innovative power flow controller is presented based on a Resistive ES (Electric Spring) in combination with a PEAT (Power Electronics based Adjustable Transformer), which can effectively shape the load power flow at the subnetwork level. With a PEAT incorporated in the step down transformer at the grid side, the proposed controller can supply non-critical loads through local RESs, and the critical loads can draw a relatively constant power from the grid. If there is an abundance of power produced by the RESs, the controller can supply both non-critical loads and critical loads through the RES, which significantly reduces the power demand from the grid. The principle, practicality, stability analysis, and controller design are presented. In addition, simulation results show that the power flow controller performs well in shaping the load power flow at the subnetwork level, which decreases the power demand on the grid. Experimental results are also provided to show that the controller can be realized.

데이터에 의한 구동과 세분화된 비트-슬라이스의 동적제어를 통한 저전력 2-D DCT/IDCT 구조 (A Low-Power 2-D DCT/IDCT Architecture through Dynamic Control of Data Driven and Fine-Grain Partitioned Bit-Slices)

  • 김견수;류대현
    • 한국멀티미디어학회논문지
    • /
    • 제8권2호
    • /
    • pp.201-210
    • /
    • 2005
  • 본 논문에서는 입력 데이터 특성을 반영하여 전력 효율이 좋은 2차원 DCT/IDCT 구조를 제안한다. 일반적으로 비디오와 영상 데이터 압축에 있어서 제로 또는 작은 값들이 입력 데이터의 많은 부분을 차지하므로 제안 방식에서는 이러한 특성을 이용하여 소모 전력을 줄인다. 특히, 간단한 AND와 비트-슬라이스 매스크(MASK)를 사용하여 곱셈기와 누산기 (accumulator) 내에서 제로를 곱하는 것을 생략하고 요구되는 세분화된 가산기들의 비트-슬라이스를 동적으로 활성화 또는 비 활성화한다. 제안 방식을 1-D DCT/IDCT에 적용하여 얻은 결과에서는 매트릭스 전치에서 전력 절감을 위해 이용되는 불필요한 부호확장비트(SEBs)를 갖고 있지 않음을 보여주고 있다. 비트 레벨 트랜지션 빈도 시뮬레이션(bit-level transition activity simulations)을 통해 기존의 설계에 비해 뚜렷한 전력 절감 효과를 확인하였다.

  • PDF

면진 원전 면진-비면진구간 연결 배관의 내진성능 평가 (Seismic Performance Evaluation of Piping System Crossing the Isolation Interface in Seismically Isolated NPP)

  • 함대기;박준희;최인길
    • 한국지진공학회논문집
    • /
    • 제18권3호
    • /
    • pp.141-150
    • /
    • 2014
  • A methodology to evaluate the seismic performance of interface piping systems that cross the isolation interface in the seismically isolated nuclear power plant (NPP) was developed. The developed methodology was applied to the safety-related interface piping system to demonstrate the seismic performance of the target piping system. Not only the seismic performance for the design level earthquakes but also the performance for the beyond design level earthquakes were evaluated. Two artificial seismic ground input motions which were matched to the design response spectra and two historical earthquake ground motions were used for the seismic analysis of piping system. The preliminary performance evaluation results show that the excessive relative displacements can occur in the seismically isolated piping system. If the input ground motion contained relatively high energy in the low frequency region, we could find that the stress response of the piping system exceed the allowable stress level even though the intensity of the input ground motion is equal to the design level earthquake. The structural responses and seismic performances of piping system were varied sensitively with respect to the intensities and frequency contents of input ground motions. Therefore, for the application of isolation system to NPPs and the verification of the safety of piping system, the seismic performance of the piping system subjected to the earthquake at the target NPP site should be evaluated firstly.

A New Unity Power Factor Rectifier System using an Active Waveshaping Technique

  • Choi, Se-Wan;Bae, Young-Sang
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.173-179
    • /
    • 2009
  • This paper proposes a new three-phase diode rectifier system with a sinusoidal input current at unity power factor and a regulated and isolated output voltage at low level. The inherent natural wave-shaping capability of the reduced kVA polyphase transformer together with an active current wave-shaping technique results in a significant reduction of input and output filter requirements associated with switching ripple and EMI. The operation principles are described along with a design example and a comparative evaluation. Experimental results on a 1.5kW prototype are provided to validate the proposed concept.

An Eight-Way Radial Switch Based on SIW Power Divider

  • Lee, Dong-Mook;An, Yong-Jun;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • 제12권3호
    • /
    • pp.216-222
    • /
    • 2012
  • This paper presents a single-pole eight-throw switch, based on an eight-way power divider, using substrate integrate waveguide(SIW) technology. Eight sectorial-lines are formed by inserting radial slot-lines on the top plate of SIW power divider. Each sectorial-line can be controlled independently with high level of isolation. The switching is accomplished by altering the capacitance of the varactor on the line, which causes different input impedances to be seen at a central probe to each sectorial line. The proposed structure works as a switching circuit and an eight-way power divider depending on the bias condition. The change in resonant frequency and input impedance are estimated by adapting a tapered transmission line model. The detailed design, fabrication, and measurement are discussed.

VIENNA 정류기를 이용한 입력파형의 개선 (Improvement of Input Wave Using VIENNA Rectifier)

  • 정헌선;노세진;최재호;정교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.19-21
    • /
    • 2007
  • This paper proposes an input waveform improvement using VIENNA Rectifier(three-phase/level/switch). VIENNA Rectifier is based on the combination of a three-phase diode bridge and dc/dc converter. It features low input current ripple and sinusoidal mains current form.

  • PDF