• 제목/요약/키워드: Input power level

검색결과 585건 처리시간 0.028초

3레벨 컨버터를 이용한 철도차량용 주 전력변환장치 (A Main Power Supply for Railway Vehicles using 3-level converters)

  • 노성찬;김윤호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.646-652
    • /
    • 2003
  • AS a main Power Supply of the Railroad Vehicles, a three-Level ZVZCS DC/DC Converter is proposed in this paper. The proposed three-Level DC/DC Converter achieves zero voltage and zero current switching for the main switches. Its attribute is that the voltage across the switches is half the value of the input voltage. Also. using a diode and secondary side of the transformer, and simple auxiliary circuits it achieves zero current switching of the auxiliary switches. The principle operation and simulation results are included.

  • PDF

원전시설의 내진성능평가를 위한 입력지반운동의 최소개수 (Minimum Number of Input Ground-motions to Assess Seismic Performance of Nuclear Facilities)

  • 홍기증;최지혜;김현욱;주광호
    • 한국지진공학회논문집
    • /
    • 제20권5호
    • /
    • pp.341-349
    • /
    • 2016
  • Currently, researches are being actively conducted in assessing seismic performance of nuclear facilities in USA and Europe. In particular, applying this technique of assessing seismic performance to design of isolation systems in nuclear power plants is being performed and then ASCE 4 Draft (2013) is being revised accordingly in the United States. In order to satisfy the probabilistic performance objectives described by seismic responses with certain confidence levels (ASCE 43, 2005), the probability distributions of these responses have to be defined. What is the minimum number of input ground-motions to obtain the probability distribution precise enough to represent the unknown actual distribution? Theoretical basis, for how to determine the minimum number of input ground-motions for given a logarithmic standard deviation to approximate the unknown actual median of the log-normal distribution within a range of error at a certain level of confidence, is introduced by Huang et al. (2008). However, the relationship between the level of confidence and the range of error is not stated in the previous study. In this paper, based on careful reviews on the previous work, the relationship between the level of confidence and the range of error is logically and explicitly stated. Furthermore, this relationship is also applied to derive the minimum number of input ground-motions in order to approximate the unknown actual logarithmic standard deviation. Several recommendations are made for determining the minimum number of input ground-motions in probabilistic assessment on seismic performance of facilities in nuclear power plants.

전력증폭기 성능개선을 위한 디지털 제어장치 설계 (Digital Control Unit Design for Power Amplifier Performance Improvement)

  • 이병선;노희정
    • 전자공학회논문지 IE
    • /
    • 제47권4호
    • /
    • pp.34-38
    • /
    • 2010
  • 본 논문에서 DCU는 기지국 전력증폭기의 성능을 안정적으로 유지하여 기지국 전체의 성능과 안정성 유지에 기여한다. 제안된 DCU는 전력증폭기에 공급되는 전력을 제어하며 실험에 사용한 앰프는 정격 입력이 10dBm일 때 정격 출력은 47.8dBm 이다. 성능의 비교는 DCU를 적용 했을 때와 미적용 했을 때를 비교하였고 연구결과 DCU가 IMD의 열화 경계에서 안정적으로 잘 동작 하였으며 전력증폭기가 매우 안정적으로 동작했다. DCU 없이 입력을 정격 보다 2dB 올렸을 때 IMD는 3~4dB 정도 나빠짐을 볼 수 있었다. 측정 결과를 보면 DSP를 이용한 제어가 유효하다는 것을 입증한다.

저 전력 아키텍처를 위한 상위 레벨 데이터 패스 할당 알고리즘 (A High-Level Data Path Allocation Algorithm for Low Power Architecture)

  • 인치호
    • 전기전자학회논문지
    • /
    • 제7권2호
    • /
    • pp.166-171
    • /
    • 2003
  • 본 논문은 상위 레벨 합성에서의 레지스터와 자원 할당 과정의 스위치 동작 최소화를 통한 저 전력 데이터 패스 할당 알고리즘을 제안한다. 제안하는 알고리즘은 스케줄링된 CDFG를 입력으로 할당 과정에서 전력 최소화를 수행한다. 알고리즘은 레지스터 할당과 자원 할당 과정을 나누어 수행한다. 레지스터 할당 알고리즘은 기능 장치내의 불필요한 스위칭 동작을 제거하고 멀티플렉서의 수를 최소화한다. 자원 할당 과정은 스위칭 동작을 최소화할 수 있는 연산자의 순서를 선택한다. 본 논문에서 제안하는 알고리즘과 genesis-lp 상위 레벨 합성시스템을 벤치마크를 이용한 비교 실험결과 평균 15.3%의 전력 감소효과가 있다.

  • PDF

소용량 직류단 커패시터를 가지는 3-레벨 NPC 인버터의 입-출력 전류 품질 향상을 위한 제어 기법 (A Control Scheme for Quality Improvement of Input-Output Current of Small DC-Link Capacitor Based Three-Level NPC Inverters)

  • 인효철;김석민;박성수;이교범
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.369-372
    • /
    • 2017
  • This paper presents a control scheme for three-level NPC inverters using small DC-link capacitors. To reduce the inverter system volume, the film capacitor with small capacitance is a promising candidate for the DC-link. When small capacitors are applied in a three level inverter, however, the AC ripple component increases in the DC-link NPV (neutral point voltage). In addition, the three-phase input grid currents are distorted when the DC-link capacitors are fed by diode rectifier. In this paper, the additional circuit is applied to compensate for small capacitor systems defect, and the offset voltage injection method is presented for the stabilization in NPV. These two proposed processes evidently ensure the quality improvement of the input grid currents and output load currents. The feasibility of the proposed method is verified by experimental results.

Spatio-temporal Load Forecasting Considering Aggregation Features of Electricity Cells and Uncertainties in Input Variables

  • Zhao, Teng;Zhang, Yan;Chen, Haibo
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.38-50
    • /
    • 2018
  • Spatio-temporal load forecasting (STLF) is a foundation for building the prediction-based power map, which could be a useful tool for the visualization and tendency assessment of urban energy application. Constructing one point-forecasting model for each electricity cell in the geographic space is possible; however, it is unadvisable and insufficient, considering the aggregation features of electricity cells and uncertainties in input variables. This paper presents a new STLF method, with a data-driven framework consisting of 3 subroutines: multi-level clustering of cells considering their aggregation features, load regression for each category of cells based on SLS-SVRNs (sparse least squares support vector regression networks), and interval forecasting of spatio-temporal load with sampled blind number. Take some area in Pudong, Shanghai as the region of study. Results of multi-level clustering show that electricity cells in the same category are clustered in geographic space to some extent, which reveals the spatial aggregation feature of cells. For cellular load regression, a comparison has been made with 3 other forecasting methods, indicating the higher accuracy of the proposed method in point-forecasting of spatio-temporal load. Furthermore, results of interval load forecasting demonstrate that the proposed prediction-interval construction method can effectively convey the uncertainties in input variables.

전력조류계산을 위한 학습용GUI에 관한 연구 (A Study on the Learning GUI for the Load Flow of Power System)

  • 이희영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.27-29
    • /
    • 2004
  • This paper presents improved teaching and learning Gill for easily analysis tool of load flow of power system. This GUI includes not only contingency analysis function, but also calculating power loss from transmission line flow. The Gill is friendly for study for power system operation and control because picture provide a better visualizing of relationships between input parameters and effect than a tabula type result. This Gill enables topology and the output data of load flow for line outages to be shown on same picture page. Users can input the system data for power flow on the the picture and can easily see the the result diagram of bus voltage, bus power, line flow. It is also observe the effects of different types of variation of tap, shunt capacitor, loads level, line outages. Proposed Gill has been studied on the Ward-Hale 6-Bus system.

  • PDF

저온 Poly-Si TFT를 이용한 저소비전력 레벨 쉬프터 (A Low-Power Level Shifter Using Low Temperature Poly-Si TFTs)

  • 안정근;최병덕;권오경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.747-750
    • /
    • 2005
  • In this paper, we propose a new level shifter circuit for reducing power consumption. The concept of the proposed level shifter is to use capacitive coupling effect to reduce short circuit current. The power consumption of the proposed level shifter is reduced up to 50%, compared to the conventional level shifter. Especially the proposed level shifter circuit works well with low temperature poly-Si (LTPS) TFTs. It can operate on low input voltage even with low-mobility, high and widely-varying threshold voltage of LTPS TFT.

  • PDF

An Isolated High Step-Up Converter with Non-Pulsating Input Current for Renewable Energy Applications

  • Hwu, Kuo-Ing;Jiang, Wen-Zhuang
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1277-1287
    • /
    • 2016
  • This study proposes a novel isolated high step-up galvanic converter, which is suitable for renewable energy applications and integrates a boost converter, a coupled inductor, a charge pump capacitor cell, and an LC snubber. The proposed converter comprises an input inductor and thus features a continuous input current, which extends the life of the renewable energy chip. Furthermore, the proposed converter can achieve a high voltage gain without an extremely large duty cycle and turn ratio of the coupled inductor by using the charge pump capacitor cell. The leakage inductance energy can be recycled to the output capacitor of the boost converter via the LC snubber and then transferred to the output load. As a result, the voltage spike can be suppressed to a low voltage level. Finally, the basic operating principles and experimental results are provided to verify the effectiveness of the proposed converter.

Selective Harmonic Elimination in Multi-level Inverters with Series-Connected Transformers with Equal Power Ratings

  • Moussa, Mona Fouad;Dessouky, Yasser Gaber
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.464-472
    • /
    • 2016
  • This study applies the selective harmonic elimination (SHE) technique to design and operate a regulated AC/DC/AC power supply suitable for maritime military applications and underground trains. The input is a single 50/60 Hz AC voltage, and the output is a 400 Hz regulated voltage. The switching angles for a multi-level inverter and transformer turns ratio are determined to operate with special connected transformers with equal power ratings and produce an almost sinusoidal current. As a result of its capability of directly controlling harmonics, the SHE technique is applicable to apparatus with congenital immunity to specific harmonics, such as series-connected transformers, which are specially designed to equally share the total load power. In the present work, a single-phase 50/60 Hz input source is rectified via a semi-controlled bridge rectifier to control DC voltage levels and thereby regulate the output load voltage at a constant level. The DC-rectified voltage then supplies six single-phase quazi-square H-bridge inverters, each of which supplies the primary of a single-phase transformer. The secondaries of the six transformers are connected in series. Through off-line calculation, the switching angles of the six inverters and the turns ratios of the six transformers are designed to ensure equal power distribution for the transformers. The SHE technique is also employed to eliminate the higher-order harmonics of the output voltage. A digital implementation is carried out to determine the switching angles. Theoretical results are demonstrated, and a scaled-down experimental 600 VA prototype is built to verify the validity of the proposed system.