• Title/Summary/Keyword: Input Voltage

Search Result 3,222, Processing Time 0.036 seconds

A Charge Pump Design with Internal Pumping Capacitor for TFT-LCD Driver IC (내장형 펌핑 커패시터를 사용한 TFT-LCD 구동 IC용 전하펌프 설계)

  • Lim, Gyu-Ho;Song, Sung-Young;Park, Jeong-Hun;Li, Long-Zhen;Lee, Cheon-Hyo;Lee, Tae-Yeong;Cho, Gyu-Sam;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1899-1909
    • /
    • 2007
  • A cross-coupled charge pump with internal pumping capacitor, witch is advantages from a point of minimizing TFT-LCD driver IC module, is newly proposed in this paper. By using a NMOS and a PMOS diode connected to boosting node from VIN node, the pumping node is precharged to the same value each pumping node at start pumping operation. Since the lust-stage charge pump is designed differently from the other stage pumps, a back current of pumped charge from charge pumping node to input stage is prevented. As a pumping clock driver is located the font side of pumping capacitor, the driving capacity is improved by reducing a voltage drop of the pumping clock line from parasitic resistor. Finally, a layout area is decreased more compared with conventional cross-coupled charge pump by using a stack-MIM capacitors. A proposed charge pump for TFT-LCD driver IC is designed with $0.13{\mu}m$ triple-well DDI process, fabricated, and tested.

Research on Power Converters for High-Efficient and Light-Weight Auxiliary Power Supplies (APS) in Railway System (철도차량 보조전원장치의 고효율-경량화를 위한 전력변환회로 연구)

  • Lee, Jae-Bum;Cho, In-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.3
    • /
    • pp.329-338
    • /
    • 2017
  • A recent trend of technical development in auxiliary-power-supplies (APS) is to replace 60Hz low frequency transformers with isolated type dc/dc converters. This paper introduces the technical trend in APS structures and proposes a power converter circuit suitable for high-efficient and light-weight APS. By utilizing the resonant converter, which achieves ZCS, to reduce switching losses, various types of APS structures (1-stage and 2-stage) are reviewed, and they are verified by simulation. The full-bridge resonant LLC converter is designed with a 1-stage power converting structure; the resonant converter topology is designed with a 2-stage power converting structure that has a pre-regulator converter to compensate for the wide input voltage range. Both a step-down converter and a step-up converter are designed and compared for the pre-regulator in the 2-stage structure. Operational characteristics are compared with simulation results and loss analyses are presented to proposes appropriate system structure and topologies.

Design and fabrication of Ka-band high-power, high-efficiency spatial combiner using TM01 mode Transducer (TM01 모드 변환을 이용한 Ka 대역 고출력 고효율 공간 결합기 설계 및 제작)

  • Kim, Hyo-Chul;Cho, Heung-Rae;Lee, Ju-Heun;Lee, Deok-Jae;An, Se-Hwan;Lee, Man-Hee;Joo, Ji-Han;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.25-32
    • /
    • 2021
  • In this study, it proposes a mode converter that is relatively easy to implement and can shorten the transmission line length of the final combining port and it was fabricated and tested by applying it to an 8-way spatial combiner. The proposed mode converter converts the signal converted from the doorknob-shaped circular disk connected to the ground into the TM01 mode by opening it in the circular waveguide. The 8-way waveguide spatial combiner is designed and implemented so that 8 signals input from the H-plane are combined in a circular waveguide at the center, and the final combining mode is TM01. The test results confirmed excellent performance with an insertion loss of less than 0.4dB and a combining efficiency of 95% or more. In addition, it was confirmed that it is suitable for high output by calculating the breakdown voltage and discharge threshold power of the new mode conversion structure through electric field analysis. The results confirmed through this study are expected to be applicable to high-power, high-efficiency SSPA in various fields in the future.

Design of 4th Order ΣΔ modulator employing a low power reconfigurable operational amplifier (전력절감용 재구성 연산증폭기를 사용한 4차 델타-시그마 변조기 설계)

  • Lee, Dong-Hyun;Yoon, Kwang-Sub
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1025-1030
    • /
    • 2018
  • The proposed modulator is designed by utilizing a conventional structure employing time division technique to realize the 4th order delta-sigma modulator using one op-amp. In order to reduce the influence of KT/C noise, the capacitance in the first and second integrators reused was chosen to be 20pF and capacitance of third and fourth integrators was designed to be 1pF. The stage variable technique in the low power reconfigurable op-amp was used to solve the stability issue due to different capacitance loads for the reduction of KT/C noise. This technique enabled the proposed modulator to reduce the power consumption of 15% with respect to the conventional one. The proposed modulator was fabricated with 0.18um CMOS N-well 1 poly 6 metal process and consumes 305uW at supply voltage of 1.8V. The measurement results demonstrated that SNDR, ENOB, DR, FoM(Walden), and FoM(Schreier) were 66.3 dB, 10.6 bits, 83 dB, 98 pJ/step, and 142.8 dB at the sampling frequency of 256kHz, oversampling ratio of 128, clock frequency of 1.024 MHz, and input frequency of 250 Hz, respectively.

A 0.2V DC/DC Boost Converter with Regulated Output for Thermoelectric Energy Harvesting (열전 에너지 하베스팅을 위한 안정화된 출력을 갖는 0.2V DC/DC 부스트 변환기)

  • Cho, Yong-hwan;Kang, Bo-kyung;Kim, Sun-hui;Yang, Min-Jae;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.565-568
    • /
    • 2014
  • This paper presents a 0.2V DC/DC boost converter with regulated output for thermoelectric energy harvesting. To use low voltages from a thermoelectric device, a start-up circuit consisting of native NMOS transistors and resistors boosts an internal VDD, and the boosted VDD is used to operate the internal control block. When the VDD reaches a predefined value, a detector circuit makes the start-up block turn off to minimize current consumption. The final boosted VSTO is achieved by alternately operating the sub-boost converter for VDD and the main boost converter for VSTO according to the comparator outputs. When the VSTO reaches 2.4V, a buck converter starts to operate to generate a stabilized output VOUT. Simulation results shows that the designed converter generates a regulated 1.8V output from an input voltage of 0.2V, and its maximum power efficiency is 60%. The chip designed using a $0.35{\mu}m$ CMOS process occupies $1.1mm{\times}1.0mm$ including pads.

  • PDF

MXene Based Composite Membrane for Water Purification and Power Generation: A Review (정수 및 발전을 위한 맥신(MXene) 복합막에 관한 고찰)

  • Seohyun Kim;Rajkumar Patel
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.181-190
    • /
    • 2023
  • Wastewater purification is one of the most important techniques for controlling environmental pollution and fulfilling the demand for freshwater supply. Various technologies, such as different types of distillations and reverse osmosis processes, need higher energy input. Capacitive deionization (CDI) is an alternative method in which power consumption is deficient and works on the supercapacitor principle. Research is going on to improve the electrode materials to improve the efficiency of the process. A reverse electrodialysis (RED) is the most commonly used desalination technology and osmotic power generator. Among many studies conducted to enhance the efficiency of RED, MXene, as an ion exchange membrane (IEM) and 2D nanofluidic channels in IEM, is rising as a promising way to improve the physical and electrochemical properties of RED. It is used alone and other polymeric materials are mixed with MXene to enhance the performance of the membrane further. The maximum desalination performances of MXene with preconditioning, Ti3C2Tx, Nafion, and hetero-structures were respectively measured, proving the potential of MXene for a promising material in the desalination industry. In terms of osmotic power generating via RED, adopting MXene as asymmetric nanofluidic ion channels in IEM significantly improved the maximum osmotic output power density, most of them surpassing the commercialization benchmark, 5 Wm-2. By connecting the number of unit cells, the output voltage reaches the point where it can directly power the electronic devices without any intermediate aid. The studies around MXene have significantly increased in recent years, yet there is more to be revealed about the application of MXene in the membrane and osmotic power-generating industry. This review discusses the electrodialysis process based on MXene composite membrane.

The Research On the Energy Storage System Using SuperCapacitor (슈퍼커패시터를 적용한 에너지 저장시스템 설계에 관한 연구)

  • Kim, IL-Song
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.11
    • /
    • pp.215-222
    • /
    • 2018
  • In this paper, the research on the energy storage system adapting super-capacitor has been performed. The most advanced features compared to the conventional lead-acid battery systems is that it can obtain high power capability due to the super capacitor power characteristics. The suggested system can attain high power in short times and achieve high power quality improvements. The application areas are power quality improvement system, motor start power which requires high power during transient times. The energy conversion system consists of bi-directional converter and inverter and advantages of high speed, high power charging and discharging performances. The design steps for the two loop controller of the bi-directional inverter are suggested and verified by the experiment and manufacturing. The two loop controller design starts from linearized transfer function which is calculated from the state averaging model including state decoupling method. The current controller requirements are 20% overshoot and settling time and voltage controller are no overshoot and settling time which is 10 times longer than current controller. The design is verified from the step input response. The designed controllers have unity power factor characteristics and thus can improve the power quality of the grid. It also has fast response time and zero steady state error.

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF